![Fagor CNC8 070 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/fagor/cnc8-070/cnc8-070_error-code-list_3215668013.webp)
CNC8070
R
EF
. 0402
E
RROR
SOLUTIONS
Page 7 of 128
Errors 0000-0999
0089
'It starts up with a single channel due to errors detected in machine parameters.'
DETECTION
Machine parameter validation.
CAUSE
Errors or warnings have come up while validating machine parameters related to the
axes or spindles of a channel.
For example, a channel has an axis (CHAXISNAME) associated to it, but it is not on
the list of the system axes (AXISNAME). Being impossible to configure the n
channels, the CNC starts up with a configuration of a single channel.
SOLUTION
Change the machine parameters to prevent the other warnings or errors related to
the other machine parameters from coming up. This warning is removed without
having to change parameter NCHANNEL (number of channels)
0090
'It starts up with the default axis configuration due to errors in machine
parameters'
DETECTION
Machine parameter validation.
CAUSE
Errors or warnings have come up while validating machine parameters related to the
axes or spindles.
For example, the number of axes (NAXIS) is greater than the elements of the list that
contains the names of the axes (AXISNAME). Being impossible to start up with the
user configuration, the CNC starts up with the default configuration.
SOLUTION
Change the machine parameters to prevent the other warnings or errors related to
the other machine parameters from coming up.
0091
'Sercos variables having the same identifier (ID) cannot have different
mnemonic'
DETECTION
Machine parameter validation.
CAUSE
In the sercos variables table of machine parameters (OEM, DRIVEVAR, DATA) some
variables have been written with the same name (MNEMONIC) and different sercos
identifier (ID).
SOLUTION
Assign the same name to the sercos variables having the same identifier (ID).
0092
'Sercos variables having the same identifier (ID) cannot have different MODE or
TYPE'
DETECTION
Machine parameter validation.
CAUSE
In the sercos variables table of machine parameters (OEM, DRIVEVAR, DATA) some
variables have been written with the same identifier (ID) and different TYPE
(Synchronous or Asynchronous) or different MODE (Read or Write).
SOLUTION
Assign the same MODE and TYPE to the sercos variables having the same identifier
(ID).
0093
'Sercos variables having the same name (MNEMONIC) cannot have different ID,
MODE or TYPE'
DETECTION
Machine parameter validation.
CAUSE
In the sercos variables table of machine parameters (OEM, DRIVEVAR, DATA) some
variables have been written with the same name (MNEMONIC) and different TYPE
(Synchronous or Asynchronous) or different MODE (Read or Write) or different
Sercos identifier (ID).
SOLUTION
Assign the same MODE, TYPE and ID to the sercos variables having the same name
(MNEMONIC).
0100
'Too many variables waiting to be reported'
DETECTION
During execution.
CAUSE
It informs that the number of variables that have been modified and that must be
reported to the interface exceeds the maximum allowed.
SOLUTION
Press the [ESC] key.
0104
'Communication time out'
DETECTION
During execution.
CAUSE
It does not end successfully the reading / writing of an external variable.
SOLUTION
Contact your supplier.
Содержание CNC8 070
Страница 1: ...CNC8070 R EF 0402 ERROR SOLUTIONS...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 84: ...CNC8070 REF 0402 OF 128 ERROR SOLUTIONS Page 78 of 128 Errors 1000 1999...
Страница 110: ...CNC8070 REF 0402 OF 128 ERROR SOLUTIONS Page 104 of 128 Errors 6000 6999...
Страница 116: ...CNC8070 REF 0402 OF 128 ERROR SOLUTIONS Page 110 of 128 Errors 7000 7999...
Страница 130: ...CNC8070 REF 0402 OF 128 ERROR SOLUTIONS Page 124 of 128 Tool and tool magazine table...
Страница 133: ...CNC8070 REF 0402 ERROR SOLUTIONS Page 127 of 128...
Страница 134: ...CNC8070 REF 0402 ERROR SOLUTIONS Page 128 of 128...