Remote modules.
CNC 8060
CNC 8065
7.
RCS-S-4F4
AO (SERCOS-II
PROTOCOL).
Error codes and
messa
ges on the Sercos co
unter.
·152·
(R
EF
: 1906)
7.9.1
Alarm codes. Meaning and solution.
A201 Fagor digital feedback. Analog signal < 0.4 Vpp. E21A feedback.
A301 Fagor digital feedback. Analog signal < 0.4 Vpp. E21B feedback.
A401 Fagor digital feedback. Analog signal < 0.4 Vpp. E21C feedback.
A501 Fagor digital feedback. Analog signal < 0.4 Vpp. E21D feedback.
Level of signal 1 Vpp too low. Check the cable and the connection between the encoder and the RCS-S
module. If the error persists, try replacing the encoder module and/or the cable associated with the
feedback. If the problem persists, contact Fagor Automation.
A202 Fagor digital feedback. Encoder power outside desired values. E21A.
A302 Fagor digital feedback. Encoder power outside desired values. E21B.
A402 Fagor digital feedback. Encoder power outside desired values. E21C.
A502 Fagor digital feedback. Encoder power outside desired values. E21D.
Check that the power supply cable of the encoder is not damaged. Also check that the cable length is
the right one and that the wiring connection is the right one. If the problem persists, contact Fagor
Automation.
A203 Fagor digital feedback. Excessive axis speed. E21A feedback.
A303 Fagor digital feedback. Excessive axis speed. E21B feedback.
A403 Fagor digital feedback. Excessive axis speed. E21C feedback.
A503 Fagor digital feedback. Excessive axis speed. E21D feedback.
The axis moving speed exceeds the sampling capability of the Sercos counter hardware for this type
of encoder signal. Decrease the maximum axis moving speed. If the problem persists, contact Fagor
Automation.
A204 Fagor digital feedback. Internal temperature is out of range. E21A feedback.
A304 Fagor digital feedback. Internal temperature is out of range. E21B feedback.
A404 Fagor digital feedback. Internal temperature is out of range. E21C feedback.
A504 Fagor digital feedback. Internal temperature is out of range. E21D feedback.
The wiring, the feedback device or the feedback of the Sercos counter may have some problem. Check
the condition (shape) of the cable, of the connection or of the feedback device. If the problem persists,
contact Fagor Automation.
A205 Fagor digital feedback. Loss of SOL synchronization. E21A feedback.
A305 Fagor digital feedback. Loss of SOL synchronization. E21B feedback.
A405 Fagor digital feedback. Loss of SOL synchronization. E21C feedback.
A505 Fagor digital feedback. Loss of SOL synchronization. E21D feedback.
The FeeDat protocol has a SOL (Sign of Life) counter that increases its value every time the master
reads the coordinate. With each interruption in the reading, the counter increases its own software count,
which must be kept so that it matches the SOL of the protocol. This warning occurs when the two counts
do not match.
Содержание CNC 8060
Страница 1: ...Ref 1906 8060 8065 CNC Remote modules...
Страница 8: ...BLANK PAGE 8...
Страница 14: ...BLANK PAGE 14...
Страница 16: ...BLANK PAGE 16...
Страница 18: ...BLANK PAGE 18...
Страница 20: ...BLANK PAGE 20...
Страница 24: ...BLANK PAGE 24...
Страница 26: ...BLANK PAGE 26...
Страница 28: ...BLANK PAGE 28...
Страница 30: ...Remote modules CNC 8060 CNC 8065 1 PREVIOUS INFORMATION 30 REF 1906...
Страница 32: ...Remote modules CNC 8060 CNC 8065 2 HARDWARE STRUCTURE 32 REF 1906...
Страница 164: ...Remote modules CNC 8060 CNC 8065 7 RCS S 4F4AO SERCOS II PROTOCOL Software installation update 164 REF 1906...
Страница 177: ...Remote modules CNC 8060 CNC 8065 177 User notes REF 1906...
Страница 178: ...Remote modules CNC 8060 CNC 8065 178 User notes REF 1906...
Страница 179: ...Remote modules CNC 8060 CNC 8065 179 User notes REF 1906...