The procedure for converting to a different gas for each model of gas oven is described below. This conversion
should only be carried out by an authorised technical service. To ensure that the conditions of the appliance correspond to
those defined at the factory, check that the CO values are less than 1000 ppm and the Lambda value is between 1.2-1.4
(VERY VERY IMPORTANT)
ACG-AG-APG 061 Models:
QUEMADOR CONVECCION/ Hot-air burner
Ignition Speed
Max. Speed
Min. Speed
Ø Injector
Reference
LPG
(G30-G31)
3500
5700
3600
Ø 4.4
12039657
NG
(G20)
4000
6500
4200
Ø 6
12039566
QUEMADOR VAPOR/ Steam burner
Ignition Speed
Max. Speed
Ø Injector
Reference
LPG
(G30-G31)
4000
4300
Ø 3.5
12045658
NG
(G20)
4000
5000
Ø 4.55
12039565
ACG-AG-APG 101 Models:
QUEMADOR CONVECCION/ Hot-air burner
Ignition Speed
Max. Speed
Min. Speed
Ø Injector
Reference
LPG
(G30-G31)
5000
6000
3600
Ø5
12039570
NG
(G20)
5000
7500
4000
Ø7
12039569
QUEMADOR VAPOR/ Steam burner
Ignition Speed
Max. Speed
Ø Injector
Reference
LPG
(G30-G31)
5000
5700
Ø 3.5
12045658
NG
(G20)
5000
6400
Ø 4.55
12039565
ACG-AG-APG 102 Models:
QUEMADOR CONVECCION/ Hot-air burner
Ignition Speed
Max. Speed
Min. Speed
Ø Injector
Reference
LPG
(G30-G31)
5000
6000
3300
Ø 5.4
12045672
NG
(G20)
5000
7500
4000
Ø 8
12045673
QUEMADOR VAPOR/ Steam burner
Ignition Speed
Max. Speed
Ø Injector
Reference
LPG
(G30-G31)
5500
5800
Ø 5.4
12045672
NG
(G20)
5500
6600
Sin Inyector
Содержание ADVANCE CONCEPT
Страница 16: ...16 11 2012 16 ACG 101 AG 101 APG 101 A Soft water intake C Mains supply D Drainage E Gas inlet F Air inlet...
Страница 17: ...16 11 2012 17 ACG 201 AG 201 APG 201 A Soft water intake C Mains supply D Drainage E Gas inlet F Air inlet...
Страница 18: ...16 11 2012 18 ACG 102 AG 102 APG 102 A Soft water intake C Mains supply D Drainage E Gas inlet F Air inlet...
Страница 19: ...16 11 2012 19 ACG 202 AG 202 APG 202 A Soft water intake C Mains supply D Drainage E Gas inlet F Air inlet...
Страница 20: ...16 11 2012 20 ACE 061 AE 061 APE 061 A Soft water intake C Mains supply D Drainage...
Страница 21: ...16 11 2012 21 ACE 101 AE 101 APE 101 A Soft water intake C Mains supply D Drainage...
Страница 22: ...16 11 2012 22 ACE 201 AE 201 APE 201 A Soft water intake C Mains supply D Drainage...
Страница 23: ...16 11 2012 23 ACE 102 AE 102 APE 102 A Soft water intake C Mains supply D Drainage...
Страница 24: ...16 11 2012 24 ACE 202 AE 202 APE 202 A Soft water intake C Mains supply D Drainage...
Страница 86: ...99 16 11 2012 86...
Страница 92: ...99 16 11 2012 92...
Страница 93: ...99 16 11 2012 93...
Страница 94: ...99 16 11 2012 94...
Страница 95: ...99 16 11 2012 95...
Страница 98: ...99 16 11 2012 98 NOTES NOTES NOTES NOTES...