CONNECTION TO GAS
CONNECTION TO GAS
CONNECTION TO GAS
CONNECTION TO GAS
Gas connection
Warning:
•
The gas installation may only be connected by an authorised local gas technician.
•
It is essential to ensure that the gas supply pipes and the connection pipes for the corresponding
measurement systems are the correct diameter.
•
Check that the gas supply is correctly sealed.
Maximum consumption with nominal thermal load
Type of gas
Pressure
required
fluidity
(mbar)
ACG-061
AG-061
APG-061
ACG-101
AG-101
APG-101
ACG-201
AG-201
APG-201
ACG-102
AG-102
APG-102
ACG-202
AG-202
APG-202
Natural gas H G-20 (m³/h)
20
1.270
1.905
3.809
3.704
6.878
Butane gas G-30 (kg/h)
30
0.998
1.498
2.995
2.912
5.408
Propane gas G-31 (kg/h)
37
0.984
1.476
2.951
2.869
5.329
The quantity of air required for the combustion is 2m
3
/h per kW power.
Remarks:
•
Observe the regulations issued by the local gas company.
•
Observe the regulations for the installation.
•
Check that the gas indicated in the section is identical to that supplied.
•
A pipe of at least Ø 12 x 10 mm should be used for the gas connection to the appliance, together with a ¾”
nut to connect to the oven.
•
Gas shut-off valve in front of each appliance.
Warning:
If the pipe pressure is different to the fluid pressure, please contact the gas company. For natural gas, the
appliance must not be started at pressures above 30 mbar. Close the gas inlet to the appliance.
Warning
Service pressures exceeding 60 mbar are not allowed as some of the oven's components could become
unusable.
Ventilation
The appliances must be installed in such a way as to allow adequate ventilation to prevent the unauthorised
concentration in the premises of products emitted during combustion which may be harmful to health.
The installation of an extraction hood is recommended for the extraction of smoke and steam in compliance with
the UNE–100165:92 standard. It is advisable that the hood sticks out 200-400 mm from the front part of the
appliance.
We recommend the annual maintenance by an authorised technician of the components relating to the
gas installation.
Shut-off valve
Содержание ADVANCE CONCEPT
Страница 16: ...16 11 2012 16 ACG 101 AG 101 APG 101 A Soft water intake C Mains supply D Drainage E Gas inlet F Air inlet...
Страница 17: ...16 11 2012 17 ACG 201 AG 201 APG 201 A Soft water intake C Mains supply D Drainage E Gas inlet F Air inlet...
Страница 18: ...16 11 2012 18 ACG 102 AG 102 APG 102 A Soft water intake C Mains supply D Drainage E Gas inlet F Air inlet...
Страница 19: ...16 11 2012 19 ACG 202 AG 202 APG 202 A Soft water intake C Mains supply D Drainage E Gas inlet F Air inlet...
Страница 20: ...16 11 2012 20 ACE 061 AE 061 APE 061 A Soft water intake C Mains supply D Drainage...
Страница 21: ...16 11 2012 21 ACE 101 AE 101 APE 101 A Soft water intake C Mains supply D Drainage...
Страница 22: ...16 11 2012 22 ACE 201 AE 201 APE 201 A Soft water intake C Mains supply D Drainage...
Страница 23: ...16 11 2012 23 ACE 102 AE 102 APE 102 A Soft water intake C Mains supply D Drainage...
Страница 24: ...16 11 2012 24 ACE 202 AE 202 APE 202 A Soft water intake C Mains supply D Drainage...
Страница 86: ...99 16 11 2012 86...
Страница 92: ...99 16 11 2012 92...
Страница 93: ...99 16 11 2012 93...
Страница 94: ...99 16 11 2012 94...
Страница 95: ...99 16 11 2012 95...
Страница 98: ...99 16 11 2012 98 NOTES NOTES NOTES NOTES...