- 24 -
GB
Strabuc 918 and Strabuc 930
PIC. 11
PIC. 12
PIC. 13
Once all the electric wires have been put in place, terminate by fastening the
Aluminium collar
and the
Cover
: lubricate the fixing screws of the collar and retractable
post cover using grease (Pic. 11).
ARRANGING THE MAGNETIC COILS
IMPORTANT: check that there are no sources of disturbance such as to conceal or influence the magnetic/electromagnetic detections of any metal detector
coils in the immediate vicinity of the installation accessories.
The magnetic coil safety accessory is always activated to detect transiting road vehicles. It prevents the traffic post from rising when vehicles pass over the coils.
A hole must be prepared (see relative instruction sheet).
Specifications should always be observed for correct magnetic coil operation.
Collar fastening screws
Collar
Screws for fastening cover
Cover
Rubber edge
Drilled flange
for rubber edge tightening
Entry coil
Entry coil
Exit coil
Exit coil
GREASE
IMPORTANT: LUBRICATE THE FOUR
CLAMPING SCREWS IN THE COLLAR
AND THE THREE COVER SCREWS WITH
GREASE.
- Pre-assembled loop 6 meters across
(optional in the catalogue).
- Pre-assembled loop 12 meters across
(optional in the catalogue).
Power supply cable
10 meters max.,
pre-fitted to the loops
Strabuc 918
Strabuc 930
min 80 cm
Metal detector. See instructions
included with the equipment
(optional in the catalogue).