Strabuc 918 and Strabuc 930
- Assemble the
support plates
to be cemented into the
ground by fitting them inside the slots in the
cylindrical
container
and fasten them by the provided screws
(Pic. 4).
- Dig a hole measuring 80x80 cm and approximately 1,20 m deep, where the Strabuc 918 or Strabuc 930 are to be installed: these measurements are adequate
for inserting and cementing the
cylindrical container
at ground level (Pic.5). Simultaneously, it is important to dig a hole in the ground to take a
corrugated
flexible pipe
(max ø 50 mm) to the
cylindrical container
, passing through the hole as provided in the container, in order to house the electric wires to be
connected to the
Elpro S40
electronic programmer (to be installed in a protected place).
- Before positioning the
cylindrical container
, arrange a 20 cm-deep layer of pebbles for rainwater drainage.
It is important that once the cylindrical container has been placed on the pebbles, the upper portion is flush with the ground level.
INSTALLATION OF THE CYLINDRICAL HOUSING TO BE CEMENTED INTO THE GROUND
PIC. 4
PIC. 5
Washer
Support plate
to be cemented
underground
M10x30
screws
Spirit level
Hole depth appr
o
ximat
ely 120-125 cm
30 cm
32 cm
ø 8 cm
15-20 cm
ø 40,5 cm
Concrete cast
80 x 80 cm
Support plates
to be cemented
Pipe, minimum ø 50, for housing electric wires
connected to the electric programmer
Strabuc housing
Loose pebble drainage layer
ø 405
ø 462
Spirit level
IMPORTANT: take care to avoid power or water pipes when digging. Arrange a water drainage layer beneath the dig.
IMPORTANT: once the housing has been positioned, before cementing, use a spirit level to ensure that it is absolutely level, to allow perfect
vertical movement of the traffic control post.
IMPORTANT: the flooring or tarmac must be level
with the container upper edge.