- 23 -
GB
Strabuc 918 and Strabuc 930
6)
7)
Strabuc 930
Heavy Armoured
Strabuc 930
Heavy Armoured
M10x30 hexagonal
head screws
Cover
Rubber edge
Drilled flange
for edge tightening
Eyebolt
Eyebolt
Corrugated
flexible tube
about 6 - 8 metres
Pebble drainage layer
Cylindrical
container
to becemented
into the ground
Eyebolt
Retractable
post
Manual release
cover security flap
PIC. 9
PIC. 10
ATTENTION: as Strabuc 918 or Strabuc 930 come complete with a series of electric cables, each one 10 metres long, during all these
traffic post installation operations, never tug at or charge electric wires for any reason. During Strabuc 918 or Strabuc 930 maintenance
or removal operations DO NOT CUT THE ELECTRIC WIRES, remove them from the pipes.
Align the traffic post cylinder holes
with those in the cylindrical container
cemented into the ground.
Pull the electric cables to
the Elpro S40 programmer
without tugging
For distances greater than 10 metres, make extensions using seale
djunction boxes inside an accessible dividing box.
Below ground wiring housed inside
a corrugated pipe
Elpro S40
1 - Limit switches
Junction
boxes
Seal the junction boxes
using bands
2 - Power supply 230 V
3 - LED and buzzer power (optional)
4 - Solenoid valve (optional)
ATTENTION: measure the distance between the traffic post installed and the Elpro S40 programmer: once the Strabuc has been
positioned and fastened, all the electric cables must rest freely on the bottom of the cylindrical housing. If the distance is greater, the
wires should be extended using sealed joints (junction boxes) inside an accessible dividing box, according to good installation practice:
this will prevent malfunctions and will guarantee efficient operation over time.