16
ENGLISH
7.3
Safety valve (ref. 10)
The safety valve has been set for the highest permitted
pressure of the pressure vessel.
It is prohibited to adjust the safety valve. Actuate the
safety valve from time to time to ensure that it works when
required. Turn the nut until it is completely loose. Then
pull the nut with sufficient force until you can hear the
compressed air being released (Fig. 3). Then release the
nut, and screw it back on.
Always keep the safety valve and the surrounding area
clean and free of obstructions.
7.4 Storage
Warning!
Disconnect the plug from the socket, vent the
appliance and tools connected to it and empty the
condensate.
Switch off the compressor and make sure that it is
secured in such a way that it cannot be started up
again by any unauthorized person.
Warning!
Store the compressor only in a dry location which is
not accessible to unauthorized persons.
Always store upright, never tilted!
8. DISPOSAL AND RECYCLING
Pursuant to Directive 2012/19/EU on
waste electrical and electronic equipment (WEEE).
The symbol carrying a crossed-out refuse container
depicted on any equipment or the relative packaging
means that, at the end of its useful life, said product must
be disposed of separately from other waste.
The user must therefore take said equipment to the
centres specialising in differentiated refuse collection of
electric and electronic equipment or alternatively return
it to the reseller when purchasing a new similar piece of
equipment.
Thanks to differentiated refuse collection, discarded
equipment can be sent to be recycled, treated and disposed
of in an environmentally-friendly manner; this helps
avoiding possible negative effects on the environment
and on health and promotes the re-employment and/or
recycling of the equipment’s materials.
Any unauthorised disposal of the product by the user will
result in the application of the fines provided for by the
regulations in force.
9. POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES
Fault
Cause
Remedy
The compressor stops and restarts
automatically after a few minutes.
Tripping of the thermal cutout due to
overheating of the motor.
Allow the compressor to cool down.
Ventilate the work area.
After a few attempts to restart, the
compressor stops.
Tripping of the thermal cutout due to
overheating of the motor (removal
of the plug with the compressor
running, low power voltage).
Activate the
I/O
switch (On/Off).
Ventilate the work area. Wait a few
minutes. The compressor will restart
independently.
The compressor does not stop and
the safety valve is tripped.
Irregular compressor operation or
pressure switch malfunction.
Remove the plug and contact the
Service Center.
Any other type of operation must be carried out by authorized Service Centers, requesting original
parts. Tampering with the machine may impair its safety and in any case make the warranty null
and void.
Содержание FCXCMS156RE
Страница 1: ...779 1000R Final page size A5 148mm x 210mm WWW FACOM COM FCXCMS156RE ...
Страница 7: ...7 3 2 1 9 7 12 5 6 8 10 11 4 1 Open 3 Closed 2 3 10 ...
Страница 21: ...21 ...
Страница 22: ...22 ...