II

for the safety, reliability and performance issues and
any monitoring abnormality, human injury and
equipment damage due to users' negligence of the
operation instructions. The manufacturer

s warranty

service does not cover such faults.

Owing to the forthcoming renovation, the specific
products you received may not be totally in
accordance with the description of this User Manual.
We would sincerely regret for that.

This product is medical device, which can be used
repeatedly.

WARNING:

Uncomfortable or painful feeling may appear
if using the device ceaselessly, especially for
the microcirculation barrier patients. It is
recommended that the sensor should not be
applied to the same finger for over 2 hours.

For the special patients, there should be a
more prudent inspecting in the placing
process. The device can not be clipped on the
edema and tender tissue.

III

The light (the infrared is invisible) emitted
from the device is harmful to the eyes, so the
user and the maintenance man should not
stare at the light.

Testee can not use enamel or other makeup.

Testee

s fingernail can not be too long.

Please refer to the correlative literature about
the clinical restrictions and caution.

This device is not intended for treatment.

The User Manual is published by our company. All
rights reserved.

Содержание CMS-50D Plus

Страница 1: ......

Страница 2: ...the Pulse Oximeter s features and requirements main structure functions specifications correct methods for transportation installation usage operation repair maintenance and storage etc as well as th...

Страница 3: ...evice ceaselessly especially for the microcirculation barrier patients It is recommended that the sensor should not be applied to the same finger for over 2 hours For the special patients there should...

Страница 4: ...s Check the main unit and all accessories periodically to make sure that there is no visible damage that may affect patient s safety and monitoring performance about cables and transducers It is recom...

Страница 5: ...r is not permitted Refer to User Manual in the relative chapter 7 1 for 3 instructions of cleaning and disinfection Do not have the oximeter immerged in liquid When it needs cleaning please wipe its s...

Страница 6: ...able It is only necessary for patients to put one of his fingers into a probe for diagnosis and a display screen will directly show the measured value of pulse oxygen saturation with the high veracity...

Страница 7: ...sitive element information acquired through which will be shown on screen through treatment in electronic circuits and microprocessor Figure 1 7 4 Technical specifications 4 1 Main performance A SpO2...

Страница 8: ...nm 6 75mW 5 Installation 5 1 View of the front panel Figure 2 front view 5 2 Battery installation A Refer to Figure 3 and insert the two AAA size batteries properly in the right direction 9 B Replace...

Страница 9: ...tion The icon of SpO2 is a program for receiving real time data which is shown as figure 5 the icon of SpO2 Review is a program for receiving stored data which is shown as figure 6 11 a Please connect...

Страница 10: ...nds and then the screen will be automatically shut down only a flashing yellow dot appear on screen If short press the button at this moment the sign Recording would appear on the screen and then the...

Страница 11: ...sensor should not be used at a location 15 or limb tied with arterial canal or blood pressure cuff or receiving intravenous injection E Do not fix the SpO2 sensor with adhesive or else it may result i...

Страница 12: ...n shows C Take out the battery if leave the equipment unused for long time D The device needs to be calibrated once a year or according to the calibrating program of hospital It also can be performed...

Страница 13: ...vice 1 Please change batteries 2 Please Install the battery again 3 Please contact the local service center The display is off suddenl y 1 The device s malfunction 2 The battery is drained away or alm...

Страница 14: ...ion Specification Information Display Mode The Pulse Oxygen Saturation SpO2 2 digit digital OLED display Pulse Rate PR 3 digit digital OLED display Pulse Intensity bar graph bar graph OLED display SpO...

Страница 15: ...Moving calculate the Average pulse rate every 4 cardio beat s cycle The deviation between average value and true value does not exceed 1 Safety Type Interior Battery Type 23 Pulse Intensity Range Con...

Страница 16: ...24 Dimensions 58 5 L 31 W 32 H mm Weight About 50g with the batteries...

Страница 17: ...File Ver 0 9 Release Date March 2009...

Отзывы: