UI Menu Description
2
-24
2
Z Offset
This menu allows you to correct the gap between the nozzle and the bed, and the height difference between the
nozzle 1 and the nozzle 2.
1
You can press the
[Start]
button to perform Z-offset auto-calibration. It automatically measures the gap between
the nozzle and the bed, and the height difference between the nozzle 1 and the nozzle 2, and saves the c
alibration values.
Important
- Clean the tip of the nozzle thoroughly before performing the automatic calibration.
Debris on the tip of the nozzle can interfere with the measurement and cause inaccurate height calibration.
Note
- The auto-calibration operation may take some time as it includes nozzle cleaning operation
and preheating operation.
- It is recommended to perform automatic calibration in the following situations.
When the printer is installed for the first time
If you replace the nozzle
If you have moved the printer far away
2
If you want to additionally calibrate the height of the nozzle, press the
[Additional Calibration]
button on the
upper right corner to move to the additional calibration screen. On this screen, you can print a calibration pattern,
and you can use the output to enter additional calibration values.
Содержание A530
Страница 8: ......
Страница 26: ......
Страница 27: ...Preparation for Use 1 type A530 ...
Страница 39: ...UI Menu Description 2 type A530 ...
Страница 71: ...Print 3 type A530 ...
Страница 76: ......
Страница 77: ...Output checking 4 type A530 ...
Страница 83: ...Maintenance 5 type A530 ...
Страница 104: ...Maintenance 5 22 5 4 Close the top door ...
Страница 110: ...5 28 Maintenance 5 3 Loosen the two nozzle fixing screws on the front by turning counterclockwise Nozzle Fixing Screws ...
Страница 111: ...5 29 Maintenance 5 4 Pull the nozzle core forward and lift it up to remove it ...
Страница 116: ......
Страница 117: ...Appendix 6 type A530 ...