![Faber LEVANTE G LEVG24SS300 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/faber/levante-g-levg24ss300/levante-g-levg24ss300_installation-instructions-use-and-care-information_3673927005.webp)
5
ELECTRICAL REQUIREMENTS
A 120 volt, 60 Hz AC-only electrical supply is required on a separate 15 amp fused circuit.
A time-delay fuse or circuit breaker is recommended. The fuse must be sized per local
codes in accordance with the electrical rating of this unit as specified on the serial/rating
plate located inside the unit near the field wiring compartment.
ELECTRICAL INSTALLATION WITH WIRING BOX
THIS UNIT MUST BE CONNECTED WITH COPPER WIRE ONLY. Wire sizes must conform
to the requirements of the National Electrical Code, ANSI/NFPA 70 - latest edition, and all
local codes and ordinances. Wire size and connections must conform with the rating of
the appliance. Copies of the standard listed above may be obtained from:
National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
This appliance should be connected directly to the fused disconnect (or circuit breaker)
through flexible, armored or nonmetallic sheathed copper cable. Allow some slack in
the cable so the appliance can be moved if servicing is ever necessary. A UL Listed,
1/2" conduit connector must be provided at each end of the power supply cable (at
the appliance and at the junction box).
When making the electrical connection, cut a 1 1/4" hole in the wall. A hole cut through
wood must be sanded until smooth. A hole through metal must have a grommet.
• Electrical ground is required on this Range Hood.
• If cold water pipe is interrupted by plastic, nonmetallic gaskets or other
materials, DO NOT use for grounding.
• DO NOT ground to a gas pipe.
• DO NOT have a fuse in the neutral or grounding circuit. A fuse in the neutral
or grounding circuit could result in electrical shock.
• Check with a qualified electrician if you are in doubt as to whether the Range
Hood is properly grounded.
• Failure to follow electrical requirements may result in a fire.
WARNING
!
State of California Proposition 65 Warning (US only)
WARNING
This product contains chemicals known to the State of California to cause cancer
and birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov
Содержание LEVANTE G LEVG24SS300
Страница 6: ...6 RANGE HOOD DIMENSIONS 3 23 15 16 29 15 16 35 15 16 3 23 15 16 29 15 16 35 15 16 24 30 24 30...
Страница 7: ...7 MIN 24 OVER ELECTRIC MIN 30 OVER GAS INSTALLATION HEIGHT REQUIREMENTS Min 24 30...
Страница 39: ...39 DIMENSIONS DE LA HOTTE 3 23 15 16 29 15 16 35 15 16 3 23 15 16 29 15 16 35 15 16 24 po 30 po 24 po 30 po...
Страница 72: ...72 DIMENSIONES DE LA CAMPANA DE COCINA 3 23 15 16 29 15 16 35 15 16 3 23 15 16 29 15 16 35 15 16 24 30 24 30...
Страница 73: ...73 M N 24 SOBRE PLACA EL CTRICA M N 30 SOBRE PLACA DE GAS REQUISITOS DE ALTURA DE LA INSTALACI N M n 24 30...