The first time the appliance is switched on, Let the fire run on maximum setting for 

several hours so that the lacquer coating will have an opportunity to set and 

possible vapours released can be safely removed by ventilation. We advise you to 

be  outside the room as much as possible during this process! 

 

Please, note that: 

 

all transport packaging should be removed.  

 

children and pets should not be present in the room. 

 

3

 

Installation requirements 

3.1

 

The fire  

 

This appliance must be installed in a chlorine-free environment. 

 

The appliance must be built into an existing or a newly to be constructed false 

chimney breast. 

3.2

 

False chimney breast 

 

The false chimney breast must be constructed of a non-combustible material. 

 

Always ventilate the space above the appliance by means of the grills or a 

comparable alternative with a minimum air supply of 200 cm². 

 

Keep a free distance of min. 50mm on the back site of the fire (See fig. 1.1) 

 

For the finish, use special stucco (min. 100°C resistant) or glass fibre wallpaper to 

prevent discoloration or cracks etc. Recommended drying time: for plaster is a 

minimum of 24 hours per mm of coat applied. 

 

The false chimney breast and its construction may not rest on the appliance.  

3.3

 

 Requirements flue system and outlets 

 

You should always make use of the materials prescribed by Faber International Ltd. 

Only by using these materials can Faber International Ltd. guarantee a proper 

functioning. 

 

The outside of the concentric flue material can reach a temperature of  

Approx 150°C. Make sure of proper insulation and protection in case of transit 

through combustible wall or ceiling constructions. And observe sufficient distance. 

 

Make sure that the concentric flue materials are bracketed every 2m. when they 

have an extended length, so that the weight of the flue material is not resting on 

the appliance  itself. 

 

You may never start with a cut-down concentric pipe directly on to the appliance. 

Содержание Fyn 450 ENG

Страница 1: ...Installation manual Fyn 450 ENG 40010929 1840...

Страница 2: ...1 L 1 1 1 2 1 3 1 4 1 5 1 6 2 1 2 2 2 3...

Страница 3: ...2 L 3 1 3 2 4 0 4 1 4 2 4 3 4 4...

Страница 4: ...ome hotter than 100 C Do not use the remote control and or app outside the room where the fire is located So that you are always aware of the situation around the fireplace when it is being operated C...

Страница 5: ...p a free distance of min 50mm on the back site of the fire See fig 1 1 For the finish use special stucco min 100 C resistant or glass fibre wallpaper to prevent discoloration or cracks etc Recommended...

Страница 6: ...100mm should have a CE mark for temperatures up to 600 Celsius The chimney should comply with the following requirements The diameter of the flue system must be at least 150x150mm There should be no m...

Страница 7: ...rizontal parts must be installed at a 3 degree slope up away the appliance Build up the system from the appliance If this is not possible you should make use of an adjustable pipe For fitting the syst...

Страница 8: ...e appliance is used 6 Placing the decorative material It is not allowed to add different or more materials to the combustion chamber Always keep the pilot burner free from decorative material Do not t...

Страница 9: ...and easily 7 2 Checking for gas leakage Check all connections and joins for possible gas leaks by means of a gas leak detector or spray 7 3 Checking the burner pressure and the pre pressure Check whe...

Страница 10: ...leakage in case of blue flames Whether the correct flue restrictor has been mounted The outlet o Wall terminal is installed correctly o Roof terminal is fitted and sited correctly The flue system is c...

Страница 11: ...ed with a dry cloth Clean the glass with Faber glass polish Note prevent fingerprints on the glass these will be burned into it once the appliance is used and cannot be removed anymore Carry out the c...

Страница 12: ...HL Start length STL This is the first part that is placed on the fire and represents a certain value fig 12 1 12 2 and 12 3 A N and F This value is in the top row of the table see restrictor table 11...

Страница 13: ...gle of 30 or 45 fig 12 1 C Fill in only in combination with at least 2x 30 or 45 bends in the vertical part Restrictor table See the restrictor table at the right vertical TVH and horizontal length TH...

Страница 14: ...0 40 x x x x 10 65 1 65 65 60 60 50 40 x x x x 11 65 1 65 65 60 60 50 40 x x x x 12 65 1 65 65 60 60 50 40 x x x x 13 65 1 65 65 60 60 50 40 x x x x 14 65 1 65 65 60 60 50 40 x x x x 15 65 1 65 65 60...

Страница 15: ...14 L 12 Examples flue materials Fig 12 1 Fig 12 2 Fig 12 3...

Страница 16: ...Bend in horizontal direction x 1 flue pipes at an angle in meters x 0 7 meter Calculation Total rounded value Total Vertical Height TVH measured height meter Total Horizontal Length THL Value Starter...

Страница 17: ...er to 130 200 and 1 meter 130 200 after that reduce to 100 150 and everything 100 150 0 5 Restrictor size Value for the comma Extra information Value behind the comma Search in the table at TVH and TH...

Страница 18: ...er requirement for permanent pilot light if applicable Ppilot 0 11 0 11 0 11 kW Additional electricity consumption At nominal heat output elmax 0 0 0 kW At minimum heat output elmin 0 0 0 kW In standb...

Страница 19: ...ance mm D Under a gutter 500 E Under a roof edge 500 F Under a carport or balcony 500 G Vertical downpipe 300 H Inside and outside corners 500 J From wall surface to a wall outlet 1000 K Two gable out...

Страница 20: ...19 L 16Troubleshooting guide...

Страница 21: ...20 L...

Страница 22: ...21 L...

Страница 23: ...22 L 17Dimensional drawings 17 1 Fyn 450...

Страница 24: ...23 L 17 2 Ventilation grid...

Страница 25: ...24 L 17 3 Remote access door...

Страница 26: ...25 L...

Страница 27: ...26 L...

Страница 28: ......

Отзывы: