The appliance can only be installed by a competent person in accordance with the Gas 

Safety. We urgently advise you to read this installation manual properly. 

This appliance complies with the Gas Appliance Regulation (EU) 2016/426.  

Harmonized standards applied EN 613 2000/A1 2003. 

 

2

 

Safety instructions 

 

Please note:                                                                                                                                                                                                                                                                                  

It is advisable to always install a screen for the fireplace if children, elderly or disabled 

people are present in the same room as the fireplace. If regularly vulnerable persons can 

be present in the room without supervision, sufficient protection must always be placed 

around the fireplace.The appliance should be placed, connected and annually checked in 

accordance with these installation instructions and valid national and local Gas Safety 

(Installation and Use) Regulations. 

 

The appliance is designed for atmospheric and heating purposes, meaning that all 

visible surfaces, including the glass, can become hotter than 100 ° C. 

 

Do not use the remote control and / or app outside the room where the fire is 

located. So that you are always aware of the situation around the fireplace when it 

is being operated. 

 

Check whether the data on the registration plate are in agreement with the local 

type of domestic gas and pressure.  

 

The fitter is not permitted to change these adjustments or the construction of the 

appliance! 

 

Do not place any additional imitation logs or glowing coals on the burner or in the 

combustion chamber. 

 

Do not use the remote control and / or app outside the room where the fireplace is 

located. So you are always aware of possible attendees and the situation around 

the fireplace when it is ignited. 

 

Do not  place any inflammable materials within a of  0,5m. of the radiation of the 

appliance and ventilation grills.  

 

Due to natural air circulation of the appliance, moisture and volatile components 

from paint, building materials, floor coverings etc. that haven’t yet set, can be 

drawn through the convection system and can be deposited on cold surfaces as 

soot. That is why you should not use the appliance shortly after a renovation.   

Содержание Fyn 450 ENG

Страница 1: ...Installation manual Fyn 450 ENG 40010929 1840...

Страница 2: ...1 L 1 1 1 2 1 3 1 4 1 5 1 6 2 1 2 2 2 3...

Страница 3: ...2 L 3 1 3 2 4 0 4 1 4 2 4 3 4 4...

Страница 4: ...ome hotter than 100 C Do not use the remote control and or app outside the room where the fire is located So that you are always aware of the situation around the fireplace when it is being operated C...

Страница 5: ...p a free distance of min 50mm on the back site of the fire See fig 1 1 For the finish use special stucco min 100 C resistant or glass fibre wallpaper to prevent discoloration or cracks etc Recommended...

Страница 6: ...100mm should have a CE mark for temperatures up to 600 Celsius The chimney should comply with the following requirements The diameter of the flue system must be at least 150x150mm There should be no m...

Страница 7: ...rizontal parts must be installed at a 3 degree slope up away the appliance Build up the system from the appliance If this is not possible you should make use of an adjustable pipe For fitting the syst...

Страница 8: ...e appliance is used 6 Placing the decorative material It is not allowed to add different or more materials to the combustion chamber Always keep the pilot burner free from decorative material Do not t...

Страница 9: ...and easily 7 2 Checking for gas leakage Check all connections and joins for possible gas leaks by means of a gas leak detector or spray 7 3 Checking the burner pressure and the pre pressure Check whe...

Страница 10: ...leakage in case of blue flames Whether the correct flue restrictor has been mounted The outlet o Wall terminal is installed correctly o Roof terminal is fitted and sited correctly The flue system is c...

Страница 11: ...ed with a dry cloth Clean the glass with Faber glass polish Note prevent fingerprints on the glass these will be burned into it once the appliance is used and cannot be removed anymore Carry out the c...

Страница 12: ...HL Start length STL This is the first part that is placed on the fire and represents a certain value fig 12 1 12 2 and 12 3 A N and F This value is in the top row of the table see restrictor table 11...

Страница 13: ...gle of 30 or 45 fig 12 1 C Fill in only in combination with at least 2x 30 or 45 bends in the vertical part Restrictor table See the restrictor table at the right vertical TVH and horizontal length TH...

Страница 14: ...0 40 x x x x 10 65 1 65 65 60 60 50 40 x x x x 11 65 1 65 65 60 60 50 40 x x x x 12 65 1 65 65 60 60 50 40 x x x x 13 65 1 65 65 60 60 50 40 x x x x 14 65 1 65 65 60 60 50 40 x x x x 15 65 1 65 65 60...

Страница 15: ...14 L 12 Examples flue materials Fig 12 1 Fig 12 2 Fig 12 3...

Страница 16: ...Bend in horizontal direction x 1 flue pipes at an angle in meters x 0 7 meter Calculation Total rounded value Total Vertical Height TVH measured height meter Total Horizontal Length THL Value Starter...

Страница 17: ...er to 130 200 and 1 meter 130 200 after that reduce to 100 150 and everything 100 150 0 5 Restrictor size Value for the comma Extra information Value behind the comma Search in the table at TVH and TH...

Страница 18: ...er requirement for permanent pilot light if applicable Ppilot 0 11 0 11 0 11 kW Additional electricity consumption At nominal heat output elmax 0 0 0 kW At minimum heat output elmin 0 0 0 kW In standb...

Страница 19: ...ance mm D Under a gutter 500 E Under a roof edge 500 F Under a carport or balcony 500 G Vertical downpipe 300 H Inside and outside corners 500 J From wall surface to a wall outlet 1000 K Two gable out...

Страница 20: ...19 L 16Troubleshooting guide...

Страница 21: ...20 L...

Страница 22: ...21 L...

Страница 23: ...22 L 17Dimensional drawings 17 1 Fyn 450...

Страница 24: ...23 L 17 2 Ventilation grid...

Страница 25: ...24 L 17 3 Remote access door...

Страница 26: ...25 L...

Страница 27: ...26 L...

Страница 28: ......

Отзывы: