18 <
<
<
<
L
15
Terminal position
Please note: These rules apply only for the proper functioning of the unit, for
ventilation and environmental protection you need to comply with the applicable
rules as defined in the building regulations.
Location
Position outlet
Distance mm
D
Under a gutter
500
E
Under a roof edge
500
F
Under a carport or balcony
500
G
Vertical downpipe
300
H
Inside and outside corners
500
J
From wall surface to a wall outlet
1000
K
Two gable outlets against over each other
1000
L
Distance between two roof outlets
450
M
Two roof outlets above each other on a pitched roof
1000
N
Two gable outlets next to each other
1000
Short roof terminal.
Only for existing
Chimney connection
Extension pipe over roof