Power Supply
24 Vdc
Nominal Power
35 W
Absorbed Current
1.5 A
Maximum Thrust Force
404 lbf (180 daN)
Stroke
13.8 in (350 mm) *
Cycles per day at 68 °F (approx)
80
Class of operation
Residential
Rod speed
0.7 in/sec (1.8 cm/sec)
Ambient Operating Temperature 4°F +131°F (-20 °C +55°C)
Operator Weight
13.2 lb (6 Kg)
Protection Class
IP54
* If the mechanical stops on opening and closing are not used
the operator stroke increases to 15.3 in (390 mm)
Dimensions in Inches
2.2 Installation Dimensions
Select the assembly position of the operator on the gate,
referring to Figure 4 and the relative table. Choose whether
or not to use the built in mechanical positive stops; eliminat-
ing the mechanical stops increases the working stroke of the
operator and values
A
and
B
must be changed.
2.1 Preliminary Checks
The structure of the gate directly influences the reliability
and safety of the automated system. To ensure correct
operation, the structure of the gate must have the following
characteristics:
• The length of leaf must conform to what is shown in the
technical specifications.
• The structure of the leaves must be sturdy and rigid, suitable
for an automated system.
• There must be regular and uniform movement of the leaves,
with no friction or sticking along their entire movement.
• Hinges must be solid and in good condition.
• Gate must swing level.
The installer is responsible for providing the main power bre-
aker switch, and for making sure that the entire gate system
meets all applicable local electrical codes.
Make sure to locate all controls that operate the gate system
at least 6 ft away from any moving parts.
Part
Description
Cables
1
Operators
2 x AWG 14 (max 30’)
AWG 12 (max 50’)
AWG 10 (max 100’)
2
Control Unit
3 x AWG 14 (AC Power)
3
TX Photocells
4 x AWG 20
4
RX Photocells
2 x AWG 20
5
Key Switch
2 x AWG 20 (1 contact)
115 Vac
60 Hz
1.2 Technical Specifications
1.3 Electrical Setup
2. INSTALLATION
α
A
B
C 1 D 2 Z 3 L E 3
With both stops
90°
6½ 6½
13
3½
3
27
4⅛
6⅞ 6⅞
13¾ 3½
3⅛
27
4⅛
110°
6
6
13⅜ 3⅛
2¾ 27
4⅛
With open stop
90°
6⅞
6½
13⅜
4
3
28
4⅛
7
7
14⅛
4
3⅛
28
4⅛
110° 6¼ 6¼
14⅛
3½ 2¾ 28
4⅛
With no stops
90°
7
7
14⅛
4
2¾ 28
4⅛
110°
6⅝ 6⅝
15
4
2¾ 28
4⅛
Fig. 3
Fig. 4
1 Working stroke of the operator.
2 Maximum value.
3 Minimum value.
Gate Length
Gate Weight
10 ft (3.0 m)
up to 720 lb (326 Kg)
12 ft (3.7 m)
up to 500 lb (227 Kg)
14 ft (4.3 m)
up to 370 lb (168 Kg)
16 ft (4.9 m)
up to 280 lb (127 Kg)