A B STP CL OP
OPEN FSW
24 VDC
Maglock
Encoder
Fig. A2
MOT
DL1
DL2
1
ON
ON
2
ON
OFF
PIN
LABEL
FUNCTION
2 EASY
2 EASY
2easy BUS input for encoders (S800H and S450H only), XIB and loop detector boards
1
OPEN A
N.O. Contact for total opening command
2
OPEN B /
CLOSE
OPEN B: N.O. Contact for opening of leaf 1 only
(with only one leaf the opening stops at 50% of traveling)
CLOSE (LOGIC B-C): N.O. Contact for closing command
3
STOP
N.C. Contact for stop command
4
FSW CL
N.C. Contact for closing safety
5
FSW OP
N.C. Contact for opening safety
6
GND (-)
24 Vdc negative
7
GND (-)
24 Vdc negative
8
+ 24
24 Vdc positive
9
OUT (-)
24 Vdc negative for safety TX photocell (monitored)
10
FCA 1
Open limit switch Motor 1
11
GND (-)
24 Vdc negative
12
FCC 1
Close limit switch Motor 1
13
FCA 2
Open limit switch Motor 2
14
GND (-)
24 Vdc negative
15
FCC2
Close limit switch Motor 2
LAMP
LAMP
Audio Alarm output
LOCK
LOCK
Output for electrical lock, max 5A pulse (DS2 - SW 4=OFF) 12 Vac / 24Vdc
Always ON (maglock): max 1 A (DS2 - SW 4=ON) 24 Vdc
MOT1
MOT 1
Motor 1 output ( first moving motor )
MOT2
MOT 2
Motor 2 output ( second moving motor )
USB A
USB
Firmware upgrade input
2. INPUTS / OUTPUTS DESCRIPTION
14