BOARD SETUP
DS 1: SW 4 to SW 12
OPENING DELAY
SW 4
The opening of leaf 2 is delayed after the opening of leaf 1. This is to avoid
the gate leafs interfering with each other during the initial part of the move-
ment. In case there is only one leaf it has no effect.
0 sec (default)
OFF
2 sec
ON
REVERSE AND LAST STROKE
SW 5
If active, before opening, while the gate is closed, the motors thrust to clo-
se for 2 s to facilitate the release of the electric lock. At closing the motors
are activated for a final stroke after slowdown to facilitate locking of the
electric lock.
inactive (default)
OFF
active
ON
MAX THRUST AT STARTUP
SW 6
With this fuction active the motors work at maximum force at startup (re-
gardless of the force setting) during the initial phase of the movement. Useful
for heavy leaves
inactive (default)
OFF
active for 3 sec
ON
AUTOMATIC OPENING IN CASE OF
POWER FAILURE
SW 7
If active and with the optional backup battery installed, the board will open
the gate after one minute from the power failure and keep it open.
Within the minute wait it’s always possible to open and close the gate with
a command. If the logic used has a pause time the board will close the
gate when the power comes back.
inactive (default)
OFF
active
ON
CLOSING SAFETY LOGIC
SW 8
With this function you can choose the behavior of the closing safety. With SW8
OFF the gate movement will be reversed as soon as the safety is active, with
SW8 ON the gate will stop when the safety is active and it will reverse only when
the safety is deactivated.
immediate reverse (default)
OFF
reverse when cleared
ON
SHADOW LOOP CONFIGURATION
SW 9
Selects the behavior of the shadow loop function of the Shadow Loop or
Loop Detectors Interface accessories.
OFF: The shadow loop input is active only before a closing command,
ignored in any other conditions
ON: The shadow loop input is active before a closing and before an opening
command. If an open command is given and the shadow loop input is
engaged the open command will be ignored even after the shadow loop
input goes inactive.
NOTE: On the first power up of the board an open command will be always
executed (even if the shadow loop is engaged), but at reduced speed.
active only on closing (default)
OFF
active on closing and opening
ON
LOCK OUTPUT CONFIGURATION
SW 10
Selects the behavior of the LOCK output:
OFF: The lock output can drive a maglock or a strike lock (see DS2)
ON: The lock output indicates the gate status or drives a warning light (see
DS2)
the output drives a regular lock
OFF
gate status or warning lamp
ON
24V ACCESSORY VOLTAGE
SW 11
Selects the behavior of the 24V accessory voltage during battery mode:
OFF: The accessory voltage and BUS input are turned off in battery
backup mode
ON: The accessory voltage and BUS input are always active even in bat-
tery backup mode
24V OFF in Battery Mode
OFF
24V ON in Battery Mode
ON
FAIL SAFE MODE
SW 12
Selects the behavior of the Fail Safe (monitoring) mode:
OFF: Fail Safe is active on the closing safety photocell input (FSW CL) only
ON: Fail Safe is active on both closing safety photocell input (FSW CL) and
opening safety photocell input (FSW OP)
NOTE: if using the XIB interface the opening safety on it is also monitored.
Refers to the XIB manual for further details.
Closing Safety
OFF
Closing and Opening Safety
ON
DIP SWITCH DS1 SETTINGS FOR BOARD SETUP
19