LOGIC “EP”
PULSES
SYSTEM STATUS
OPEN A
OPEN B
STOP
FSW OP
FSW CL
FSW CL/OP
CLOSED
opens the leaves
opens leaf 1
no effect
(OPEN disabled)
no effect
(OPEN disabled)
no effect
no effect
(OPEN disabled)
OPENING
stops operation (1) stops operation stops operation
immediately
reverses at closure
no effect
stops and opens at release
(OPEN stops -
saves CLOSE)
OPEN
recloses leaves
immediately (1)
recloses leaves
immediately
no effect
(OPEN/CLOSE
disabled)
no effect
no effect
(CLOSE disabled)
no effect
(OPEN/CLOSE disabled)
CLOSING
stops operation
stops operation stops operation
no effect
reverses at opening
stops and opens at release
(OPEN stops -
saves CLOSE)
BLOCKED
restarts moving in
opposite direction.
Always closes after
STOP
restarts moving in
opposite direction.
Always closes after
STOP
no effect
(OPEN/CLOSE
disabled)
no effect
(OPEN disabled)
no effect
(CLOSE disabled)
no effect
(OPEN stops -
saves CLOSE)
LOGIC “AP”
PULSES
SYSTEM STATUS
OPEN A
OPEN B
STOP
FSW OP
FSW CL
FSW CL/OP
CLOSED
opens and closes
after pause time
opens leaf 1
and closes after
pause time
no effect
(OPEN disabled)
no effect
(OPEN disabled)
no effect
no effect
(OPEN disabled)
OPENING
stops operation
(1)
stops operation
stops operation
reverses at
closing (saves
OPEN)
no effect
stops and opens at release
(OPEN stops -
saves CLOSE)
OPEN IN PAUSE
stops operation
(1)
stops operation
stops operation
no effect
recharges
pause time
(CLOSE disabled)
recharges
pause time
(CLOSE disabled)
CLOSING
reopens leaves
immediately
reopens leaves
immediately
stops operation
no effect
reverses at opening
(see DS1-SW8)
stops and opens at release
(OPEN stops -
saves CLOSE)
BLOCKED
closes leaves
closes leaves
no effect
(OPEN/CLOSE
disabled)
no effect
(OPEN disabled)
no effect
(CLOSE disabled)
no effect
(OPEN/CLOSE disabled)
(1) if the cycle began with OPEN-B (leaf 1), both leaves are activated at opening
(1) if the cycle began with OPEN-B (leaf 1), both leaves are activated at opening
LOGIC “SP”
PULSES
SYSTEM STATUS
OPEN A
OPEN B
STOP
FSW OP
FSW CL
FSW CL/OP
CLOSED
opens and clo-
ses after pause
time
opens leaf 1 and
closes after pause
time
no effect
(OPEN disabled)
no effect
(OPEN disabled)
no effect
no effect
(OPEN disabled)
OPENING
stops operation
(1)
stops operation
stops operation reverses at closure
continues to open
and recloses
immediately
stops and opens after release and
closes immediately at end (OPEN
stops - saves CLOSE)
OPEN IN PAUSE
recloses leaves
immediately (1)
recloses leaves
immediately
stops operation
no effect
stops and, at relea-
se, closes
stops and, at release, closes
CLOSING
stops operation stops operation
stops operation
no effect
reverses at opening
stops and opens at release
(saves CLOSE)
BLOCKED
restarts moving
in opposite
direction. Always
closes after STOP
restarts moving in
opposite direction.
Always closes after
STOP
no effect
(OPEN/CLOSE
disabled)
no effect
(OPEN disabled)
no effect
(CLOSE disabled)
no effect
(OPEN/CLOSE disabled)
(1) if the cycle began with OPEN-B (leaf 1), both leaves are activated at opening
27