ND1
26
732558 - Rev. D
X 1
X 1
PRESS THE OPENING OR CLOSING BUTTON AND BRING THE SHUTTER TO THE OPEN POSITION
1) Press and hold the opening or closing button until the shutter reaches the open position and then release the button.
2) Press the stop button for 2 seconds, release it, and hold it down again until the engine performs a brief movement in both directions
to verify that the opening limit switch is set correctly.
3) Press and hold the opening or closing button until the shutter reaches the closed position and then release the button.
4) Press the stop button until the engine performs a brief movement in both directions.
5) Verify that the positions of the limit switches are correct. If the limit switches have not been set correctly, perform a reset switch
(chap. 12) and repeat the set-up procedure.
NOTE: If this procedure is performed, the automation is set to shutter 3 mode. For further details, refer to the instructions that can be
downloaded from the FAAC website.
PRESS THE STOP BUTTON FOR 2 SECONDS, RELEASE IT FOR 1 SECOND AND PRESS IT AGAIN UNTIL THE END OF THE INDICATED MOVE-
MENTS TO CONFIRM THE OPENING LIMIT SWITCH HAS BEEN STORED.
2 seconds
1 second
Fig. 40
Fig. 41
OR
WITHIN 3 SECONDS
11.6.2 MANUAL learning of the opening and closing limit switch points (SET-UP) mod. N1D SENSO KIT