ND1
23
732558 - Rev. D
N L
M
M
230Vac
50-60Hz
230Vac
50-60Hz
L
N
N
L
11 COMMISSIONING
Ear
th
Blue or gr
ey
Br
o
w
n
Connect the yellow green cable to earth.
Connect the cables to the mains power supply as shown in the
fi gure.
Do not connect N1D KIT or N1D AUTO KIT in parallel.
Check that the button is wired correctly based on the
installation made. Pressing the opening key should open the shut-
ters. If not, swap the two engine phases (brown and black wires).
The N1D model is controlled by a button and operates with the dead
man logic (the engine moves in the selected direction as long as the
button is pressed).
The N1D AUTO model is controlled by a switch and stops motion
automatically as soon as it encounters an obstacle or the mechanical
stop when opening or closing.
11.1 Electric wiring mod. N1D KIT- N1D AUTO KIT
11.2 OPEN/CLOSE selector for mod. N1D KIT and N1D AUTO KIT
The fi gure displays the dimensions and electrical connections of the OPEN/CLOSE selector of mod. N1D and N1D AUTO.
Do not connect N1D KIT or N1D AUTO KIT in parallel.
Fig. 34
Fig. 35
230 Vac
50-60Hz
Black
Brown
Black
Blue
Yellow/Green
Yellow/Green
Black
Brown
Blue
fi xed switch
or dead man
switch