24
Access Input:
Allows external Access Control Devices to activate the gate.
1. If Close Time Delay is ON, the gate will open and remain
open until the access device relay is released. Then the gate
will time out and close.
2. If Close Time Delay is OFF and the gate is in closed or open
position, the gate will travel in the opposite direction.
3. If Close Time Delay is OFF and the gate is in mid cycle, the
gate will stop. The direction will not be changed until another
valid input is made.
NOTE: Only connect devices that are in line of sight to this input.
If the access device is not in line of sight, connect it to the radio
input.
Access Control Connection
Access Control Devices such as Telephone Entry Systems, Digital Locks and Card Readers may be connected to the Access Input
to control the gate operator. When an Access Device is active, the Access LED will light.
Fire
Access
Reset
GND
GND
Stop
Close
Open
TELEPHONE ENTRY
DIGITAL LOCK
CARD READER
Fire Lock Connection
Fire Lock Controls such as Knox Locks and Fire Boxes may be connected to the Fire Input to control the gate operator. When a
Fire Lock Control is active, the Fire LED will light.
Fire Input:
Allows Fire Lock Controls to activate the gate.
1. If Close Time Delay is ON, gate will open and remain open
until the fire control relay is released. Then the gate will time
out and close.
2. If Close Time Delay is OFF and the gate is in closed position,
gate will open and remain open until an external input of any
sort closes the gate.
3. If Close Time Delay is OFF and gate is in open position,
gate will remain open until an external input is made. This
prevents the Fire Input from closing the gate if in the open
position.
Fire
Access
Reset
GND
GND
Stop
Close
Open
FIRE
NOTE: Consult your local Fire Department for proper
building codes and Fire Lock requirements.