25
Radio Receiver Connections
Radio Controls may be connected to the Radio Inputs to control the gate operator. When a Radio Control is active, the Radio LED
will light.
Radio Input:
Allows Radio Controls to activate the gate and provides 24VDC
Connecting Generic Radio Receivers:
Connect Radio Relay to RADIO N.O. and RADIO COMMON.
If the Radio Receiver uses 24VDC, connect Radio Power positive to
RADIO PWR +24VDC and Radio Power positive to RADIO PWR
-24VDC.
N.O.
+
Receiver
Radio Pwr
-24V DC
GND
N.O.
Radio Pwr
+24V DC
MagLock & Solenoid Inputs:
Allows Maglocks and Solenoid Locks to be connected to the gate
operator with a 2 second delay to open.
Maglocks use a NC relay contact. Solenoid Locks use a NO con-
tact. Power must be applied externally.
Connecting Solenoid & Maglocks:
1. Set Master and Slave DIP Switch 10 to ON.
2. Connect Solenoids to the external power supply and Solenoid
Com and N.C. outputs following the schematic on the right
3. Connect Maglocks to the external power supply and Maglock
Com and N.C. outputs following the schematic on the right
MagLock & Solenoid Lock Connections
Magnetic and Solenoid Locks may be connected to the controller and utilize a 2 second delay on open to help dissipate magnetic
current or solenoid power for smoother openings.
Light Com
Light N.O.
GND
TX Photo -
Maglock Com
Maglock N.C.
Solenoid Com
Solenoid N.O.
SOLENOID
MAGLOCK
Monitor Photo / Edge
Anti-Tailgate
Master / Slave
Close Timer
Power Fail Open / Cycle
Open Left / Right
Quick Close
Stop (NC / NO)
Low Battery Cycle / Open
Mag / Solenoid Delay
Monitor Close / Op-Cl
Soft Start / Hard Start
Off On
DIP SWITCH 10