A1400 AIR
103
532129 04 - Rev.B
Tr
ansla
tion of the original instruc
tions
ENGLISH
Defines the opening percentage in PARTIAL OPENING mode. The
default and interval of settings is:
-
PARTIAL OPENING 20-100
3 Board Display
Enables/disables programming from the board. The options with
relevant default are as follows:
-
Not blocked
-
Blocked
4 Safety Opening Function
Defines the safety in opening function
-
STOP
-
LOW ENERGY (Slow speed movement)
5 Intrusion
Defines door behaviour in case of attempt to open manually. The
options with relative defaults are as follows:
-
DISABLED does not actuate the motor
-
KEEP CLOSED actuates the closing motor
-
PULL & GO actuates the opening motor
(
NOT active with battery operation)
6 Partial Chemist’s Shop
It defines the opening percentage with the pharmacy control (only
active in NIGHT-TIME Mode). The default and interval of settings is:
-
PARTIAL PHARMACY
20
% (1-95)
7 SDK EVO key
Defines the operation of the key switch connected to the SDK EVO
(OPTIONAL accessory):
-
BLOCK:
The SDK EVO operates normally with the NO (Normally Open)
key switch. A password is required.
With the key switch NC (Normally Closed) the SDK EVO is locked.
-
WITHOUT USER PSW:
With the key switch NO (Normally Open), the SDK EVO works
without having to enter a password.
With the key switch NC (Normally Closed), the SDK EVO works
normally. A password is required.
8 Consecutive obstacles
Defines the number of consecutive obstacles after which the door
is blocked in error. Choose and modify the parameter:
-
CLOSING
from
no to 10
-
OPENING
from
no to 10
No stands for infinity
9 Test Error
Enables/disables movement at slower speed in the event of TEST
ERROR on safety devices.
-
ENABLED
-
DISABLED
10 Display backlighting
Enables the backlighting of the display.
-
ALWAYS
(backlighting is always enabled)
-
DISABLED
(backlighting is disabled after 30sec of
SDKEVO key inactivity).
W
ith battery operation it is always disabled.
11 ELASTIC KIT
-
ENABLED
-
DISABLED
Default CF1 CF2 CF2 CF4 CF5
Default Configuration NO
Partial opening 50%
Board Display Not
locked
Opening Safety Function
STOP
Intrusion
Dis. Dis. Dis. Dis. Dis.
Partial Pharmacy
20%
SDK EVO key
Lock
Consecutive obstacles
0
Test Error Disabled
Display backlighting ALWAYS
3ELASTIC KIT Disabled
■
10 LOG
OK
OK
LOG
2
PROGRAMMING
MENU NOT AVAILABLE
MENU 3 ERRORS
OK
OK
OK
OK
01 BOARD FAULT
3
ERRORS
02.....................39
99 Data deletion in
progress
The display shows current errors:
-
1 Board failure
-
4 VACC fault
-
5 Microcontroller error
-
6 VMOT fault
-
7 Motor MOT1 failure
-
9 VMAIN low
-
10 Battery
discharged
-
11 S1 test failed
-
12 S2 test failed
-
15 Data in setup memory missing or corrupted
-
16 Encoder
failure
-
18 FW not compatible
-
19 High mechanical friction
-
20 Test of inputs I1-I4 configured as safeties failed
-
22 Corrupted
data
-
23 VMAIN high
-
24 Consecutive obstacles when closing
-
26 Motor block failure
-
27 Motor rotation error
-
29 AUX board fault
-
31 Consecutive obstacles during opening
-
32 Motor time out
-
33 Battery failure
-
38 Configuration error
-
39
Data in Setup memory missing or corrupted
-
99 Data deletion in progress