10. KP-CONTROLLER PROGRAMMING UNIT
KP-Controller is used for selecting operational functions, as well
as adjusting and programming the 950 Series automatic doors.
It is divided into two parts: a fixed part used for signalling of
operational functions by means of pushbuttons and relevant
signalling LEDs (Fig. 23 ref.A), and a removable part with LCD
display and selection buttons to access complete
programming (Fig. 23 ref.B).
The KP-Controller display can be used as a temporary
programming unit if the parameter "Keep settings" in the
ADVANCED MENU is set to ON: after all programming and
adjustments have been carried out, KP-Controller can be fully
removed because the settings remain stored on the 950MPS
control board.
If KP-Controller is installed without display, a cover is provided
(Fig. 23 ref.C).
KP-Controller can be disabled by a combination of keys (see
the special LOCK function) or by internally fitting a jumper by
means of a switch (Fig. 24 ref. LOCK).
10.1. MOUNTING
Refer to Fig. 24 for an exploded view of mounting; two knockout
areas marked A and B are provided for entry of connection
cable.
10.2 . CONNECTIONS
Connect KP-Controller to the 950 I/O control board by a
2x0.5mm² max 50m cable (Fig. 24).
If the two LOCK terminals are connected to each other as
shown in Fig.24, all keys on the programmer are disabled.
10.3 . DIAGNOSTICS
KP-Controller (also without display) has a diagnostic function
which, in case of an alarm, interrupts normal display of the
function every 2 seconds in order to show the fault status for 1
second by a combination of flashing LEDs.
Consult Fig. 25 and table 8 to identify the type of alarm
according to the flashing LEDs
In the event of several simultaneous faults, the code of fault
detected first is displayed.
2x0.5 mm
2
max 50m
Fig. 24
)
*
Fig. 23
)
*
+
Table 8 DIAGNOSTICS
Led =on = off
DESCRIPTION
MEANING
3 FORCED OPEN
Door forced opening in progress
7 EMERG. ON
Emergency input active
9 OBST. IN CLOS.
Closing obstacle detected 3 successive times; Reset necessary to restore operation
10
Lock locked in closed position
12
Incorrect power supply to accessories (24Vdc absent)
15
Setup not possibile
18
Initialisation process not possible on motor: leaf stroke too long
20
Initialisation process not possible on motor: insufficient leaf stroke
22
Leaf too heavy
24
Motor failure
26
950 MPS control board failure
27
No power supply
28
Setup cycle required
29
Encoder failure
30
Driver motor failure
31
EEPROM failure
32
Master/Slave communication error
Fig. 25