5.2. SETTING THE ADJUSTING TRIMMERS

The programming unit features trimmers (fig.8) which regulate the
following parameters:

Trimmer TR1

 to set the opening speed.

Setting from 4 to 10 seconds.

Trimmer TR2 

to set the closing speed.

Setting from 4 to 10 seconds.

Trimmer TR3 

to set the pause time (AUTOMATIC logic).

Setting from 0 to 30 seconds.

5.3. SIGNALLING LEDs

LD1 Led = 

Green LED - electric motor power supply.

LD2 Led = 

Red LED - indicates SET-UP/Alarm.

LD3 Led = 

Green LED - 5V power supply.

5.4.2. MICROSWITCH No. 2 - SET-UP PROCESS

When mounting the “sliding” arm or for opening angles greater
than 90°, this microswitch has to be enabled.

OFF = Function DISABLED
ON = Function ENABLED

5.4.3. MICROSWITCH No. 3 - SELECTOR FUNCTION (“ 2 ” POSITION)

This function allows the operating function to be selected with the
selector switch in the “2” position.

OFF = MANUAL Function
ON = NIGHT Function

 5.4.4. MICROSWITCH No. 4 - PUSH AND GO

When activated, this function enables the opening command to
be given by pushing the closed door manually. It is sufficient to
give the door an initial push/pull in the opening direction.

OFF = Function DISABLED
ON = Function ENABLED

WARNING

: It is advisable not to enable this function if the door is

subject to strong wind, according to its structure and dimensions,
as this could activate the system's spontaneous opening or
motion reversing.

5.4.5 . MICROSWITCHES Nos. 5/6/8/9 - INACTIVE

5.4.6. MICROSWITCH No. 7 -  STOP SAFETY DEVICE

It makes it possible to detect activation of the STOP safety device
during the entire door travel (COMPLETE) or to disable detection
beyond 70° opening (REDUCED).

OFF = COMPLETE Function
ON = REDUCED Function

When the STOP safety control is ensured by an active sensor fitted
on the leaf, if you enable the REDUCED function, the detection
of any obstacle (e.g. side wall) is prevented  which would cause
interruption of the work cycle.

5.4.7 MICROSWITCH No. 10 -  RS232 PORT

It makes it possible to enable the RS232 port connection to PC for
software update. In normal use conditions, the dip switch is in OFF
position.

OFF = Port DISABLED
ON = Port ENABLED

6. 950 I/O ELECTRONIC CONTROL UNIT

5.4. PROGRAMMING THE MICROSWITCHES (fig.9)

The programming unit has a series of microswitches which allow the
functions shown to be selected.
The system is supplied with all the microswitches in the 

OFF

 position.

5.4.1. MICROSWITCH No. 1 - CLOSING STROKE

This function enables the closed position force to be increased by
further loading the transmission system after the door has reached
the mechanical closure stop.
It is advisable to use this function to assist activation of the electric
lock.

OFF = Function DISABLED
ON = Function ENABLED

     MICROSWITCHES

 

 1   2   3   4    5   6   7   8   9   10

OFF

ON

Fig. 9

Fig. 10

6.1 LAYOUT AND DESCRIPTION

Содержание 950 BM

Страница 1: ...950BM 950BM para la naturaleza 100 papel reciclado ist umweltfreundlich 100 Altpapier pour la nature papier recycl 100 for nature recycled paper 100 carta riciclata 100 per la natura...

Страница 2: ...Fig 2a Fig 2b Fig 3 1 1 2 2 3 3 1 2 4 5 Fig 4 Fig 4b Fig 4a 6...

Страница 3: ...Fig 5 Fig 6...

Страница 4: ...onter plus de 2 rallonges Cota con eje est ndar Si fuera necesario aumentar la distancia entre el actuador y el brazo utilizar las prolongaci nes modulares opcionales Cada prolungaci n aumenta la altu...

Страница 5: ...pas monter plus de 2 rallonges Cota con eje est ndar Si fuera necesario aumentar la distancia entre el actuador y el brazo utilizar las prolongaci nes modulares opcionales Cada prolungaci n aumenta la...

Страница 6: ...pas monter plus de 2 rallonges Cota con eje est ndar Si fuera necesario aumentar la distancia entre el actuador y el brazo utilizar las prolongaci nes modulares opcionales Cada prolungaci n aumenta l...

Страница 7: ...pas monter plus de 2 rallonges Cota con eje est ndar Si fuera necesario aumentar la distancia entre el actuador y el brazo utilizar las prolongaci nes modulares opcionales Cada prolungaci n aumenta l...

Страница 8: ...under the provisions of Directive 98 37 EC conforms to the essential safety requirements of the following EEC directives 73 23 EEC and subsequent amendment 93 68 EEC 89 336 EEC and subsequent amendme...

Страница 9: ...ol Board 950 MPS Power supply 230 Vac 6 10 50 60 Hz Accessories power supply 24 Vdc 500mA max Electric lock power supply N O N C 24 Vdc 500mA max Standard operating functions selector switch Open Auto...

Страница 10: ...lesarenotinacentral position see Mounting tables The holes are offset in order to ensurethattheoperatorismountedwiththecorrectdirectionof rotation of the mechanism The mounting tables are the followin...

Страница 11: ...in Table 7 N B The default status of the LEDs with the door closed at rest is shown in bold type Table 7 Operation of the status signalling LEDs for 950 I O board LED ON OFF LD1 Accessories power pre...

Страница 12: ...ostrongwind accordingtoitsstructureanddimensions as this could activate the system s spontaneous opening or motionreversing 5 4 5 MICROSWITCHES Nos 5 6 8 9 INACTIVE 5 4 6 MICROSWITCH No 7 STOP SAFETY...

Страница 13: ...llel 12 Emergency Command N C Contact Any pulse generator normally a pushbutton which by openingacontact commandsanemergencyclosureofthe system Alternatively this input can be used to command emergenc...

Страница 14: ...J5 TERMINAL BOARD Connection to relay Outputs figs 13 14 15 Description of the terminal board 1 Electric lock Common 2 Electric lock N O Contact max capacity 0 5 A 24 V fig 13 Ifnopowerissuppliedtheel...

Страница 15: ...able to the 950I O unit must be positioned as shown in figs 4a b The selector switch can be easily inspected by opening the protection door fig 4 ref 1 The selectable operating functions are shown in...

Страница 16: ...loading rotate the arm in closing direction until the next fixing position of the stop point screw fig 21 ref 5 is in line with the inspection slot and fix the screw again 5 Reinstall the arm correctl...

Страница 17: ...ntroller to the 950 I O control board by a 2x0 5mm max 50m cable Fig 24 If the two LOCK terminals are connected to each other as shown in Fig 24 all keys on the programmer are disabled 10 3 DIAGNOSTIC...

Страница 18: ...ctivated The internal and external radars are disabled The Key command causes opening and closing after the night pause time elapses standard 7 sec Adjusting range of night pause time from 0 to 30 sec...

Страница 19: ...eys or to select sub menu or parameter and confirm with the OK key An asterisk on the display indicates the currently active setting To exit programming select the exit function at each level Otherwis...

Страница 20: ...ENGLISH Diagram 3 Setup Diagram 4 Lock SETUP 80 7 SEC 2 SEC CLOSING STANDARD NO STANDARD OBSTACLE DETECTION NIGHT PAUSE TIME PARTIAL OPENING PAUSE TIME EXIT LOCK OFF ON ALWAYS ONE WAY NIGHT NIGHT KIT...

Страница 21: ...950 v DIAGNOSTICS NR CYCLE XXXX ALARM N alarm description PASSWORD 0000 PASSWORD 0000 PASSWORD 0000 PASSWORD 0000 KEEP SETTINGS OFF ON 8 8 EXIT ADVANCED MENU OPERATION PARAMETERS CLOSING SPEED OPENIN...

Страница 22: ...Out Setup PASSWORD 0000 PASSWORD 0000 PASSWORD 0000 PASSWORD 0000 IN OUT SETUP EMERG OPEN CLOSE OUT OP CL NO OUT ALARM NO NC USCITA NC NO NC ADVANCED MENU OPERATION PARAMETERS VARIOUS EXIT CHANGE PASS...

Страница 23: ...00 IN OUT SETUP STAND SETUP STANDARD NO STANDARD INTERLOCK MASTER SLAVE NO MEMORY WITH MEMORY EXIT NEW PASSWORD 0000 NEW PASSWORD 0000 NEW PASSWORD 0000 NEW PASSWORD 0000 MASTER SLAVE ON OFF ON OFF 2...

Страница 24: ...E BAND 4 FUN 0 00 00 TIME BAND 3 FUN 0 00 00 TIME BAND 1 FUN 0 00 00 TIME BAND 2 FUN 0 00 00 TIME BAND 5 FUN 0 00 00 TIME BAND 4 FUN 0 00 00 TIME BAND 3 FUN 0 00 00 TIME BAND 1 FUN 0 00 00 TIME BAND 2...

Страница 25: ...rocedure and if the cause of signalled malfunction was removed it restores normal operation 5 ADVANCED MENU PASSWORD To access the advanced menu insert the 4 digit password default 0000 1 OPERATION PA...

Страница 26: ...can create up to 5 different time bands for each day of the week by setting the band starting time and assign an operational function to each time band When the KP Controller s internal clock reaches...

Страница 27: ...or to close totally in order to activate the sensor of the second door 6 Door B opens Fig 28 Door A Door B 7 The person exits 8 Door B closes after the night pause time elapses The operation is identi...

Страница 28: ...s is immediately reversed The partial opening function enables control of total opening of the master only The operating functions must be set on the master automated system only or on the KP Controll...

Страница 29: ...sshouldbefollowed to prevent problems from arising accidentally Do not stand or allow children or adults to stand within range of the door especially during operation and do not leave objects near it...

Страница 30: ...tunas para el perfeccionamiento t cnico o para cualquier otro tipo de exigencia de car cter constructivo o comercial Timbro del Rivenditore Distributor s Stamp Timbre de l Agent Fachh ndlerstempel Sel...

Отзывы: