24
ENGLISH
ENGLISH
1.2 DOOR MAX OPENING ANGLE
According to the type of mounting and respecting the installation
dimensions shown in Tables A,B,C, or D, different door max.
opening angles can be obtained according to the lintel thickness.
Table 5 and 6 shows the maximum values of the opening angles
that can be obtained in the different configurations.
Tab.5: Door max opening angle with pushing articulated arm.
Type of installation
Jamb depth (mm)
Max opening angle
operator on lintel
0
100°
operator on lintel
125
110°
operator on lintel
250
125°
operator on door
0
100°
Tab.6: Door max opening angle with sliding arm.
Type of installation
Jamb depth (mm)
Max opening angle
operator on lintel
0
90°
arm L=430 mm
operator on lintel
160
105°
arm L=430 mm
operator on lintel
0
90°
arm L=330 mm
operator on lintel
160
90°
arm L=330 mm
2. ELECTRICAL SETUP (fig. 2a Standard system)
950 BM operator
Microwave radar / Passive infrared sensor
T20E outdoor key-operated selector switch
(KEY command)
Emergency Closing/Opening pushbutton
KP-CONTROLLER programming unit (optional)
KP-CONTROLLER inhibition switch (optional)
24 Vdc electric lock
Junction box
If the operator is installed on the door, make the electrical
connections using a junction box and suitable commercially
available pipes/unions (fig. 2b).
Notes
: 1) To lay electric cables, use suitable rigid and/or flexible
piping.
2) Always keep the low voltage accessory connection
cables separate from the 230 V power cables. To avoid
interference, use separate sheaths.
3. INSTALLATION
3.1. PRELIMINARY CHECKS
To ensure correct operation of the automated system the structure
of the existing door must meet the following requirements:
- length and weight as specified in Table 3 (paragraph 1.1.);
- max. jamb depth as specified in Table 4;
- robust and rigid structure of the leaf;
- good condition of the existing hinges;
- smooth, uniform movement of the leaf with no abnormal friction
during its entire travel;
- “neutral” position of the door during its entire travel. If the door
tends to close or open, check the alignment of the hinges.
- Presence of mechanical travel stops.
3.2. MOUNTING THE OPERATOR
1)
As regards the mounting position of the operator (on the lintel
or on the door) and the type of arm to use (pushing or sliding),
refer to the relevant mounting table and drill the holes
required to mount the operator and the pulling arm.
N.B.
: The two intermediate operator fixing holes are not in a central
position (see Mounting tables). The holes are offset in order to
ensure that the operator is mounted with the correct direction of
rotation of the mechanism.
The mounting tables are the following:
Table A: LINTEL MOUNTING (PUSHING ARTICULATED ARM):
Outward
opening.
Table B: DOOR MOUNTING (PUSHING ARTICULATED ARM):
Inward
opening.
Table C:LINTEL MOUNTING (SLIDING ARM LENGTH 330mm):
Inward
opening.
Table D: LINTEL MOUNTING (SLIDING ARM LENGTH 430mm):
Inward
opening.
2)
Mount the casing fixing brackets as shown in fig.3 according
to the type of mounting to be made. Tighten the screws (fig.3-
ref.1) and fit the screws (fig.3-ref2) without tightening them
completely.
3)
Mount the operator using the six M6 screws and washers
provided.
Warning:
- The structure of the lintel (or the door) at the operator mounting
position must not exhibit any significant deformation.
- The operator must be mounted parallel to the floor.
N.B.
: If the sliding arm is to be used, the driving arm must be
mounted before the operator is fixed on the lintel (see paragraph
3.3.2.).
3.3. MOUNTING THE DRIVING ARMS
3.3.1. MOUNTING THE PUSHING ARTICULATED ARM (fig.5)
1)
Close the door.
2)
Free arms (1) and (2) by loosening the fixing dowel (3) as shown
in fig.5.
3)
Fit arm (1) on the coupling of the operator transmission shaft
by means of the standard shaft (8) and the screw (4)
provided (fig.5). The arm must be mounted perpendicular to
the closed door.
Note:
If a greater distance between the operator and the arm is
required, use the shaft modular extensions, available as
accessories, until the required distance is reached. (see Table A/
B).
4)
Mount plate (5) of arm (2) on the door or the lintel using the
two M6 screws and the washers provided (fig. 5). The installation
dimensions are given in Table A/B.
5)
Slacken the fixing screw (6) and assemble the two arms by
tightening the dowel (3) (fig.5).
6)
Turn arm (1) until arm (2) is perpendicular to the closed door
or the lintel as shown in fig. 5 (a-b), sliding the spacer (7) along
arm (2).
7)
Tighten the fixing screw (6) between the two arms.
The length of arm (2) is given in the relevant mounting tables.
If necessary, cut off the section of the arm extending beyond
the articulation and then cover its end using the cap provided
(fig. 5).
8)
Check manually that the door is free to open and close fully
and that it comes to rest against the mechanical stops. If the
door does not close correctly, adjust the return spring as
described in paragraph 9.
Important
: The two driving arms must never touch.
Note
: it is advisable to always adjust the operator internal
mechanical stops (fig.1 -ref 4), open/closed, so that they can be
activated when the leaf mechanical stops are reached.
Содержание 950 BM
Страница 2: ...Fig 2a Fig 2b Fig 3 1 1 2 2 3 3 1 2 4 5 Fig 4 Fig 4b Fig 4a 6...
Страница 3: ...Fig 5 Fig 6...