equipment. Failure to meet this requirement could 
cause severe injury and/or death, for which the 
manufacturer cannot be held responsible. 

4.

 

The installer must provide a main power switch that 
meets all applicable safety regulations. 

5.

 

Clearly indicate on the gate with a minimum of 2 
warning signs (visible from either side of the gate) 
that indicate the following:  

 

The gate is automatic and could move at 
any time, posing a serious risk of 
entrapment.  

 

Children should not be allowed to operate 
the gate or play in the gate area. 

 

The gate should be operated only when it 
is visible to the operator and the when the 
area is free of people and obstructions. 

6.

 

It is extremely unsafe to compensate for a damaged 
gate by overtightening a clutch or increasing 
hydraulic pressure. 

7.

 

Devices such as reversing edges and photocells 
must be installed to provide better protection for 
personal property and pedestrians. Install reversing 
devices that are appropriate to the gate design and 
gate application. 

8.

 

Before applying electrical power, be sure that the 
voltage requirements of the equipment correspond 
to your supply voltage. Refer to the label on your 
operator system. 

Use 

1.

 

Use this equipment only in the capacity for which it 
was designed. Any use other than that stated should 
be considered improper and therefore dangerous. 

2.

 

When using any electrical equipment, observe 
some fundamental rules:  

 

Do not touch the equipment with damp or 
humid hands or feet. 

 

Do not install or operate the equipment 
with bare feet. 

 

Do not allow small children or incapable 
persons to use the equipment. 

3.

 

If a gate system component malfunctions, turn off 
the main power before making any attempt to repair 
it. 

4.

 

Do not attempt to impede the movement of the 
gate. You may injure yourself as a result. 

5.

 

This equipment may reach high temperatures 
during operation; therefore, use caution when 
touching the external housing of the operator. 

6.

 

Learn to use the manual release mechanism 
according to the procedures found in this in-
stallation manual. 

7.

 

Before carrying out any cleaning or maintenance 
operations, disconnect the equipment from the 
electrical supply.  

8.

 

To guarantee the efficiency of this equipment, the 
manufacturer recommends that qualified personnel 
periodically check and maintain the equipment. 

 

U.L. Class and FAAC Operator 

Model 

Duty Cycle 

Typical Use 

Class I: Residential Vehicular Gate Operator 

 402 

746 

 422 

750 

 412 

760 

 630 

Limited duty 

 

Home use 

 

Small apartment building, for example, up to 4 units 
in a building, with limited public access 

Class II: Commercial/General Access Vehicular Gate Operator 

 400 

640 

 620 

Continuous duty 

 

Apartment buildings 

 

Very public access 

Class III: Industrial/Limited Access Vehicular Gate Operator 

 400 

640 

 620 

Continuous duty 

 

No public access 

Class IV: Restricted Access Vehicular Gate Operator 

 620 

640 

Continuous 

duty 

 

Prison rated security 

 

Upswung.com

Содержание 844

Страница 1: ...s 9 Setting the Concrete Forms 9 Mounting the Operator 10 Chain Operator 10 Rack and Pinion Operator 10 Connecting the Control Panel to Power and an Activating Device 12 Setting Up the Limit Switches...

Страница 2: ...zard so it is im portant that you locate the gate far enough away from the road to eliminate the potential of traffic getting backed up This distance is affected by the size of the gate how often it i...

Страница 3: ...ng any electrical equipment observe some fundamental rules Do not touch the equipment with damp or humid hands or feet Do not install or operate the equipment with bare feet Do not allow small childre...

Страница 4: ...Z16 100 lb 45 kg 125 lb 57 kg Duty cycle motor run time at 72 F 24 C 50 1 Your standard 220 VAC power source meets the specification for 230 VAC 6 or 10 2 The maximum pulling force at start up assume...

Страница 5: ...1 8 3 1 2 in 54 89 mm 1 Heavier clutch spring for a gate leaf weighing 2200 lb 1000 kg or more 1 Grounding connector nut and washer 3 Covers for wiring access holes inside the operator If you have ord...

Страница 6: ...the gate stops exactly where and when required Two die cast flanges surround the pinion to prevent foreign objects from being inserted between the rack and pinion either accidentally or intentionally...

Страница 7: ...switch 6 If an open signal is sent while the gate is closing the gate reverses and immediately reopens S1 Security Mode Available only on the 844 MPS control panel the S1 mode of operation is similar...

Страница 8: ...n signal Leaf Status Activating Signal Stop Signal Reversing Device closed opens and then closes after pause time1 no effect no effect opening closes stops no effect opened closes immediately1 2 pause...

Страница 9: ...s the gate leaf by 12 in 46 by 30 cm Note Your soil conditions will also determine the size of the concrete footing Within the concrete forms you need to locate the electrical conduits one for high an...

Страница 10: ...operator you are installing Figure 5 Use the cover key to unlock the cover of the 844 Operator Figure 6 Lift and tilt the cover backward on the 844 Operator Chain Operator As shown in Figure 7 place t...

Страница 11: ...ually disengage the operator motor using the Manual Release see Figure 2 and open the gate by hand as far as possible Fit the spacers washers and bolts on the rack sections as shown in Figure 9 The bo...

Страница 12: ...Panel to Power and an Activating Device Note Be sure to ground the gate and operator system and protect the entire gate system with a main power breaker switch see Figure 10 Refer to your local electr...

Страница 13: ...nished with the operator activate the limit switch For the rack and pinion drive the limit switch plates are fixed on the top of the rack at each end of the gate leaf see Fig 11 In the case of the cha...

Страница 14: ...4 sec and the control panel makes a rapid clicking sound if the limit switch cable becomes disconnected or if both limit switches are triggered at the same time Correct the cabling and or cycle your m...

Страница 15: ...rn the potentiometer counterclockwise to decrease the braking force and clockwise to increase the braking force DL1 Power supply LED DL2 Open LED DL3 Close LED RL1 Closing relay RL2 Opening relay RL3...

Страница 16: ...5 F capacitor is connected 9 Terminal block J5 where the motor is connected 10 Terminal block J4 for right closing limit switch connection 11 Terminal block J3 for left closing limit switch connection...

Страница 17: ...perator The 844 B C Control Panel Connect other normally open N O opening devices in parallel to terminals 1 and 4 Connect N O closing devices in parallel to terminals 2 and 4 Devices to stop the gate...

Страница 18: ...u want the gate to pause between opening and closing The setting you make depends on the logic you have already set with DIP switches 1 and 2 If you have not yet set the logical operating mode do so b...

Страница 19: ...side the cover of the operator see Fig 1 to verify the oil covers the copper coil of the motor If more oil is needed add it through the oil filler cap Be sure to use only FAAC XD 220 or Shell Tellus 1...

Страница 20: ...e limit switch The distance between a plate and the switch should be 3 16 in 5 mm Check fuse F1 and replace it if necessary Problem The motor is running in the wrong direction Solutions Reverse the br...

Страница 21: ...ction see Figs 13 15 or 17 depending on your control panel Gate will not open or close OFF ON ON OFF OFF Check limit switch for open circuit To test control panel limit switch logic remove limit switc...

Страница 22: ...22 Upswung com...

Страница 23: ...gligence or accident or has not been operated in accordance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions more severe than or otherwise exceeding tho...

Отзывы: