Limited Warranty 

 

To the original purchaser only:

 FAAC International, Inc., warrants, for twenty-four (24) months from the date of 

invoice, the gate operator systems and other related systems and equipment manufactured by FAAC S.p.A. and distributed by 
FAAC International, Inc., to be free from defects in material and workmanship under normal use and service for which it was 
intended 

provided

 it has been properly installed and operated. FAAC International, Inc.'s obligations under this warranty shall be 

limited to the repair or exchange of any part of parts manufactured by FAAC S.p.A. and distributed by FAAC International, Inc. 
Defective products must be returned to FAAC International, Inc., freight prepaid by purchaser, within the warranty period. Items 
returned will be repaired or replaced, at FAAC International, Inc.'s option, upon an examination of the product by FAAC 
International, Inc., which discloses, to the satisfaction of FAAC International, Inc., that the item is defective. FAAC International, 
Inc. will return the warranted item freight prepaid. The products manufactured by FAAC S.p.A. and distributed by FAAC 
International, Inc., are not warranted to meet the specific requirements, if any, of safety codes of any particular state, municipality, 
or other jurisdiction, and neither FAAC S.p.A. or FAAC International, Inc., assume any risk or liability whatsoever resulting from 
the use thereof, whether used singly or in combination with other machines or apparatus. 
 

Any products and parts not manufactured by FAAC S.p.A. and distributed by FAAC International, Inc., will carry 

only the warranty, if any, of the manufacturer. This warranty shall not apply to any products or parts thereof which have been 
repaired or altered, without FAAC International, Inc.'s written consent, outside of FAAC International, Inc.'s workshop, or altered in 
any way so as, in the judgment of FAAC International, Inc., to affect adversely the stability or reliability of the product(s) or has 
been subject to misuse, negligence, or accident, or has not been operated in accordance with FAAC International, Inc.'s or FAAC 
S.p.A.'s instructions or has been operated under conditions more severe than, or otherwise exceeding, those set forth in the 
specifications for such product(s). Neither FAAC S.p.A. or FAAC International, Inc., shall be liable for any loss or damage 
whatsoever resulting, directly or indirectly, from the use or loss of use of the product(s). Without limiting the foregoing, this 
exclusion from liability embraces a purchaser's expenses for downtime or for making up downtime, damages for which the 
purchaser may be liable to other persons, damages to property, and injury to or death of any persons. Neither FAAC S.p.A. or 
FAAC International, Inc., assumes nor authorizes any person to assume for them any other liability in connection with the sale or 
use of the products of FAAC S.p.A. or FAAC International, Inc. The warranty hereinabove set forth shall not be deemed to cover 
maintenance parts, including, but not limited to, hydraulic oil, filters, or the like. No agreement to replace or repair shall constitute 
an admission by FAAC S.p.A. or FAAC International, Inc., of any legal responsibility to effect such replacement, to make such 
repair, or otherwise. This limited warranty extends only to wholesale customers who buy directly through FAAC International, 
Inc.'s normal distribution channels. FAAC International, Inc., does not warrant its products to end consumers. Consumers must 
inquire from their selling dealer as to the nature and extent of that dealer's warranty, if any. 

 

This warranty is expressly in lieu of all other warranties expressed or implied including the warranties of 

merchantability and fitness for use. This warranty shall not apply to products or any part thereof which have been subject 
to accident, negligence, alteration, abuse, or misuse or if damage was due to improper installation or use of improper power 
source, or if damage was caused by fire, flood, lightning, electrical power surge, explosion, wind storm, hail, aircraft or 
vehicles, vandalism, riot or civil commotion, or acts of God. 

 

 

FAAC International, Inc. 

303 Lexington Avenue 

Cheyenne, WY  82007 

 
 

844 IM, 6/98

 

Upswung.com

Содержание 844

Страница 1: ...s 9 Setting the Concrete Forms 9 Mounting the Operator 10 Chain Operator 10 Rack and Pinion Operator 10 Connecting the Control Panel to Power and an Activating Device 12 Setting Up the Limit Switches...

Страница 2: ...zard so it is im portant that you locate the gate far enough away from the road to eliminate the potential of traffic getting backed up This distance is affected by the size of the gate how often it i...

Страница 3: ...ng any electrical equipment observe some fundamental rules Do not touch the equipment with damp or humid hands or feet Do not install or operate the equipment with bare feet Do not allow small childre...

Страница 4: ...Z16 100 lb 45 kg 125 lb 57 kg Duty cycle motor run time at 72 F 24 C 50 1 Your standard 220 VAC power source meets the specification for 230 VAC 6 or 10 2 The maximum pulling force at start up assume...

Страница 5: ...1 8 3 1 2 in 54 89 mm 1 Heavier clutch spring for a gate leaf weighing 2200 lb 1000 kg or more 1 Grounding connector nut and washer 3 Covers for wiring access holes inside the operator If you have ord...

Страница 6: ...the gate stops exactly where and when required Two die cast flanges surround the pinion to prevent foreign objects from being inserted between the rack and pinion either accidentally or intentionally...

Страница 7: ...switch 6 If an open signal is sent while the gate is closing the gate reverses and immediately reopens S1 Security Mode Available only on the 844 MPS control panel the S1 mode of operation is similar...

Страница 8: ...n signal Leaf Status Activating Signal Stop Signal Reversing Device closed opens and then closes after pause time1 no effect no effect opening closes stops no effect opened closes immediately1 2 pause...

Страница 9: ...s the gate leaf by 12 in 46 by 30 cm Note Your soil conditions will also determine the size of the concrete footing Within the concrete forms you need to locate the electrical conduits one for high an...

Страница 10: ...operator you are installing Figure 5 Use the cover key to unlock the cover of the 844 Operator Figure 6 Lift and tilt the cover backward on the 844 Operator Chain Operator As shown in Figure 7 place t...

Страница 11: ...ually disengage the operator motor using the Manual Release see Figure 2 and open the gate by hand as far as possible Fit the spacers washers and bolts on the rack sections as shown in Figure 9 The bo...

Страница 12: ...Panel to Power and an Activating Device Note Be sure to ground the gate and operator system and protect the entire gate system with a main power breaker switch see Figure 10 Refer to your local electr...

Страница 13: ...nished with the operator activate the limit switch For the rack and pinion drive the limit switch plates are fixed on the top of the rack at each end of the gate leaf see Fig 11 In the case of the cha...

Страница 14: ...4 sec and the control panel makes a rapid clicking sound if the limit switch cable becomes disconnected or if both limit switches are triggered at the same time Correct the cabling and or cycle your m...

Страница 15: ...rn the potentiometer counterclockwise to decrease the braking force and clockwise to increase the braking force DL1 Power supply LED DL2 Open LED DL3 Close LED RL1 Closing relay RL2 Opening relay RL3...

Страница 16: ...5 F capacitor is connected 9 Terminal block J5 where the motor is connected 10 Terminal block J4 for right closing limit switch connection 11 Terminal block J3 for left closing limit switch connection...

Страница 17: ...perator The 844 B C Control Panel Connect other normally open N O opening devices in parallel to terminals 1 and 4 Connect N O closing devices in parallel to terminals 2 and 4 Devices to stop the gate...

Страница 18: ...u want the gate to pause between opening and closing The setting you make depends on the logic you have already set with DIP switches 1 and 2 If you have not yet set the logical operating mode do so b...

Страница 19: ...side the cover of the operator see Fig 1 to verify the oil covers the copper coil of the motor If more oil is needed add it through the oil filler cap Be sure to use only FAAC XD 220 or Shell Tellus 1...

Страница 20: ...e limit switch The distance between a plate and the switch should be 3 16 in 5 mm Check fuse F1 and replace it if necessary Problem The motor is running in the wrong direction Solutions Reverse the br...

Страница 21: ...ction see Figs 13 15 or 17 depending on your control panel Gate will not open or close OFF ON ON OFF OFF Check limit switch for open circuit To test control panel limit switch logic remove limit switc...

Страница 22: ...22 Upswung com...

Страница 23: ...gligence or accident or has not been operated in accordance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions more severe than or otherwise exceeding tho...

Отзывы: