manualshive.com logo in svg
background image

WARNING

It is vital for the safety of persons to follow all 

instructions. Failure to comply with the installation

instructions and the safety warnings may result in

serious personal injury and/or property and remote

control opener damage. 

Please save these instructions for future reference.

GDO-9V1 SecuraLift

®

Overhead Garage Door Opener

IIn

nsstta

alllla

attiio

on

n  IIn

nssttrru

uccttiio

on

nss

O

OW

WN

NE

ER

RS

S  C

CO

OP

PY

Y

P/N 13210

Содержание GDO-9V1 SecuraLift

Страница 1: ... and the safety warnings may result in serious personal injury and or property and remote control opener damage Please save these instructions for future reference GDO 9V1 SecuraLift Overhead Garage Door Opener I In ns st ta al ll la at ti io on n I In ns st tr ru uc ct ti io on ns s O OW WN NE ER RS S C CO OP PY Y P N 13210 ...

Страница 2: ...23 Transmitter Wall Bracket 23 Re Initialising 23 Parameter 24 Door Status Indicators 24 Quick Reference Guide 24 System Specification 25 Factory Default Settings 25 Trouble Shooting Guide 26 Maintenance Record 26 Parts List 27 Warranty 28 Automatic Technology Australia Pty Ltd to the extent that such may be lawfully excluded hereby expressly disclaims all conditions or warranties statutory or oth...

Страница 3: ...ildren or infirm persons without adequate supervision Children should be supervised to ensure that they do not play with the remote transmitters or the opener Keep hands and loose clothing CLEAR of the door and door opener at all times The unit should be installed so that it is protected from the elements It should not be exposed to water or rain It is not to be immersed in water or sprayed direct...

Страница 4: ...ourtesy light illumi nates automatically whenever the door is activated The light can also be switched on and off without operating the door This is done by pressing the button on any transmit ter which has been coded to operate the light The light will stay on for approximately three minutes then switch off This time is also adjustable BATTERY BACK UP OPTIONAL The opener has provision to include ...

Страница 5: ... opening and remains steady on when the open limit position has been reached 12 AUTO CLOSE TIME button is used to adjust the auto close time While holding in the auto close but ton and then pressing the open but ton the time is increased Each press will increase the time by 5 seconds Pressing the close button will decrease the time 13 CLOSE LIMIT LED red the led is very helpful during installation...

Страница 6: ...R CONNECTOR 9 COURTESY LIGHT MODULE 10 FORCE MARGIN BUTTON 11 OPEN LIMIT LED 12 AUTO CLOSE TIME BUTTON 13 CLOSE LIMIT LED 14 MINUS RED BUTTON 15 STATUS LED 16 DOOR CODE BLUE BUTTON 17 CODE SET LED 18 LIGHT CODE BUTTON 19 EASY ACCESS TRANSMITTER 20 SET ORANGE BUTTON 21 PE O S C CONNECTOR 20 16 14 15 19 17 13 12 18 2 3 4 5 6 7 8 9 10 11 1 OPERATING CONTROLS 6 FIG 1 21 ...

Страница 7: ...T INCLUDED IN SOME MODELS 1 KEY RING TRANSMITTER PTX 4 PACK 1 pack includes two keyring transmitters two batteries and one wall mount bracket for ptx4 transmitter C RAIL PACK 1 DOOR ATTACHMENT ARMS 2 ACCESSORY PACK 1 INSTALLATION MANUAL 1 KIT CONTENTS GDO 9V1 AUTO OPENER CH P N 00090 FIG 2 ...

Страница 8: ... PACK 1 pack includes two keyring transmitters two batteries and one wall mount bracket for ptx4 transmitter DOOR ATTACHMENT ARMS 2 ACCESSORY PACK 1 ITEMS QTY C Rail knock down assembly 1 FIG 3 FIG 4 FIG 5 See fig 4 See fig 5 8 Note chain in one piece rail has been tensioned by the factory Do not adjust the tension of the chain IMPORTANT NOTE If modification to the track length required adjustment...

Страница 9: ...9 Step 1 Unpack and assemble the C rail as shown above in fig 6 C RAIL ASSEMBLY FIG 6 ...

Страница 10: ...L ASSEMBLY Step 2 Locate and insert the shaft of drive unit into sprocket as shown in fig 7 Step 3 Fix the two track brackets as shown in fig 8 fix with four screws supplied in accessory pack FIG 7 FIG 8 10 ...

Страница 11: ...ectional panel door on tracks Fig 9 proceed with the installation from Step 5 l For a one piece door on tracks Fig 10 proceed with the installation from Step 5 l For a one piece door without tracks on springs Fig 11 proceed with the installation from Step 9 page 13 11 one piece door without track FIG 11 FIG 10 FIG 9 ...

Страница 12: ...mbly to wall bracket with 90mm long clevis pin and secure with supplied snap pin Fig 14 leaving drive unit in its packing box for protection during installation STEP 8 Raise the drive unit from the packing box and support it in a horizontal position with a step ladder then open the garage door Rest the opener on the open door and use a scrap piece of wood to bring it to horizontal level Line up th...

Страница 13: ... of drive unit mounting holes Fig 15 Do not lock screws at this stage STEP 11 Close the door slowly The opener c rail will be elevated by the top edge of the door as it moves Stop the door when it is at its highest point of travel Fig 18 Allow 25mm additional height for clearance between the door and the track Support c rail in this position and then close the door Fig 18 This will be the height t...

Страница 14: ...ses 4 mounting holes for extra strength This is used on sectional doors See Fig 20 Mount the door bracket to the centre line of the door Fig 20 using M6 or equivalent screws not supplied Alternatively it can be welded on steel doors Note As various types of doors exist if in doubt about the strength of the door reinforcement may need to be added to the frame of the door panel where necessary Damag...

Страница 15: ...n metallic object e g pen to remove the battery Gently lever the battery out of the holder taking care to not damage the circuit board Fig 24 WARNING Metallic objects used to remove the battery may damage the circuit board or the battery REPLACING THE BATTERY Make sure that positive side is facing up Place one side of the battery into the holder Fig 25 then press the battery in and down firmly unt...

Страница 16: ...r desired open limit position IMPORTANT WARNING Please be aware that the garage door will start closing automatically once step 4 is performed The door will also automatically re open after fully closing with a small pause between the cycles 4 Press the Set button This action will store into memory the door limit position The door will now automatically close to its limit position then fully open ...

Страница 17: ...s action will store into memory the closed limit position 4 Press button 1 the door will start opening Release the button once you are 1 to 2 cm from your desired open limit position inch the door to your desired open position by Pressing button 1 IMPORTANT WARNING Please be aware that the garage door will start closing automatically once step 5 is performed The door will also automatically re ope...

Страница 18: ... is usually not necessary to adjust the Safety Obstruction Force The only time the force may need to be increased is due to environmental conditions for example windy or dusty areas and areas with extreme temperature changes 17 3 TO INCREASE FORCE PRESSURE 1 Press and hold the Force Margin Set button Fig 32 2 While holding down the Force Margin button press the Plus button Each press increases the...

Страница 19: ... Press and hold Door Code button and the button Fig 35 2 Press the button on the transmitter you would like to use to control pedestrian mode for two seconds pause for two seconds Press the same button again on the transmitter for two seconds 3 Release all buttons to store the transmitter in memory 4 Press the transmitter button to test if it operates the pedestrian mode To change the default pet ...

Страница 20: ...ds the button should now be recorded 5 Wait for 10 seconds and then press the recorded transmitter button to see if it operates the door STEP 20 DELETING PROGRAMMED CODES 20 1 DELETING A STORED TRANSMITTER CODE 1 Select the transmitter you want to delete 2 Press and hold the Door Code button Fig 38 3 Press the transmitter button you would like to delete for two seconds Pause for two seconds Press ...

Страница 21: ... BEFORE USING THE AUTO CLOSE MODE The Auto Close timer will only start after the Photo Electric Beams P E path is broken and the auto close time has been set If the P E path is not broken the door will remain open till the path is broken If the Door Opener incurs an obstruction not from the P E while closing the door will re open and not auto close until the part of the P E beam is broken again SE...

Страница 22: ...and 10 4 Mount the Charger Board SBY 3 on three hex spacers pre mounted on base and secure with three 3 M4 x 8 screws 5 Feed 2 Wire battery Harness through the grummet on the base plate and connect to sby 3 6 Feed charger harness from sby 3 to control board and plug 4 pin connector marked sby 3 on the control board Warning After Step 7 the opener may become active even when power is off This is a ...

Страница 23: ... Close LEDs will flash rapidly 2 Press the Plus or Minus button Fig 44 to move the door to your required new pet open door position 3 Press the Set button Fig 44 to record the new position The Pet mode is activated from a transmitter button coded to that function When activated the door drives to the preset position from either above or below If the Pet button is pressed while the door is moving t...

Страница 24: ... then Minus Each press of the open button decreases the light time by 10 secs Force Margin Set Auto Close Time then Set Reloads the factory set default light time Minus for 6 secs Clears the door limits set positions Limits then need to be reset Set Close for 2 secs Enters pet pedestrian position mode Set the power on and hold until all LEDs are off Deletes control parameters excluding transmitter...

Страница 25: ...TYPE Code Hopping NUMBER OF CODE COMBINATIONS Over 4 29 Billion Random Codes CODE GENERATION Non linear Encryption Algorithm PTX 4 TRANSMITTER BATTERY A23 Alkaline 12 Volts EAT 1 TRANSMITTER BATTERY CR1220 Lithium 3 Volts COURTESY LIGHT LED Light emitting diodes CONTROLLER FUSE 10A Slow Blow DEFAULT SETTINGS AND SPECIFICATIONS 25 Note Intermittent operations may occur in areas which experience ver...

Страница 26: ...ng door to stiffen and become tight in the tracks Possible obstruction in the doorway Increase force margin setting See Step 17 3 on page 18 Remove obstruction Door operates from drive unit oprate button but not from transmitter See note Transmitter code not stored in memory Flat Battery Code transmitter in to openers memory Refer Step 18 on page 19 Replace battery A23 Alkaline 12V Door will not c...

Страница 27: ...SPARE PARTS LIST MANUAL RELEASE WHEN ORDERING SPARE PARTS PLEASE QUOTE THE ORDER CODE NUMBER TO YOUR INSTALLER DEALER page 27 ...

Страница 28: ...pment in a proper working order as per clauses d through i l installation adjustment or use which is not in accordance with the instructions set out in installation instruction manual m attempted or complete modification or repairs to the product carried out by a person who is not authorised or has not been trained by ATA to carry out such modification or repairs n faulty or unsuitable wiring of s...

Отзывы: