manualshive.com logo in svg
background image

Page 21 

November, 2003 

400 Operator And  
455 D Control Panel Installation Manual  

ADVANCED PROGRAMMING 

 

Display Function 

Default 

 

M

AXIMUM

  T

ORQUE

 

AT

  I

NITIAL

  T

HRUST

:  

The motors operate at maximum 

torque (ignoring the torque setting) 

at  start  of  movement.    Useful  for 

heavy leaves. 

4 = Enable 

No = Disabled 

 

 

L

AST

 S

TROKE

 

AT

 C

LOSING

The motors are activated at full 

speed for 1s to facilitate locking of 

the electric lock. 

4 = Enable 

No = Disabled 

 

 

R

EVERSING

 S

TROKE

Before opening, while the gate is 

closed, the motors thrust to close 

for 2 s thus facilitating release of the 

electric lock. 

4 = Enable 

No = Disabled

 

 

 

L

EAF

 2 O

PENING

 D

ELAY

 (2

S

): 

Enables delayed start (at opening) of 

leaf 2, avoiding interference between 

leaves. 

4 = Enable 

No = Disabled

 

 

 

F

AIL

 S

AFE

If this function is activated, it en-

ables a function test of the photo-

cells before any gate movement.  If 

the test fails (photocells not service-

able), the gate does not start the 

movement. 

 

4 = Enable 

No = Disabled

 

 

 

P

RE

 F

LASHING

 (5

S

): 

Activates the flashing lamp for 5s 

before start of movement. 

 

4 = Enable 

No = Disabled

 

 

 

E

LECTRIC

 L

OCK

 

ON

 L

EAF

 2:   

For using the electric lock on leaf 2 

instead of on leaf 1.  

 

4 = Enable 

No = Disabled

 

 

F

+

Display 

Function Default 

 

I

NDICATOR

-L

ICHT

If 0 is selected, the output functions 

as a standard indicator-light (lighted 

at opening and pause, flashing at 

closing, and off when gate closed).  

Different figures correspond to timed 

activation of the output, which can be 

used (via a relay) to power a courtesy 

lamp.    Time  can  be  adjusted  from  0 

to 59s in 1s increments, and from 1.0 

to 4.1 min. in 10s steps. 

 

0 = Standard Indicator-Light 

From 1 to 4.1 = Timed Output 

 

 

 

C

LOSING

 P

HOTOCELLS

 

REVERSE

 

AT

 

RELEASE

Enable this function if you want the 

closing photocells to stop the gate 

movement and reverse it after the 

beam is cleared. Default setting is 

immediate reverse. 

 

4 = Enable 

No = Disabled

 

 

 

A.D.M.A.P. F

UNCTION

If this function is enabled, the safety 

devices operate in compliance with 

French standard NFP 25/362. 

 

4 = Enable 

No = Disabled

 

 

 

A

SSISTANCE

 R

EQUEST

 (

COMBINED

 

WITH

 

NEXT

 

FUNCTION

): 

If activated, at the end of countdown 

(settable with the next function, i.e. 

“Cycle programming”) it effects 8s of 

pre-flashing at every Open pulse (job 

request).  Can be useful for setting 

scheduled maintenance jobs. 

 

4 = Enable 

No = Disabled

 

 

 

C

YCLE

 P

ROGRAMMING

For setting count down of system 

operation cycles.  Settable (in thou-

sands) from 0 to 99 thousand cycles.  

The displayed value is updated as 

cycles proceed.  This function can be 

used to check use of the board or to 

exploit the “Assistance Request” func-

tion.

 

 

 

E

XIT

 P

ROGRAMMING

Exit from programming and return to 

display of inputs status. 

 

T

HE

 455 D C

ON
T

R

OL

 P

AN
EL

 I

N

ST

A

LLAT

ION

 I

NST

R

UC
T

IO

N

S

 

Содержание 455 D

Страница 1: ...455 D Control Panel General Description 14 Installing the 455 D Control Panel 14 Connect the Main Power Supply 14 Connect the Operator to the Control Panel 15 Check the Motor s Direction of Rotation 1...

Страница 2: ...ons before the automatic operator is installed 4 An automatic operator should be installed on the inside of the property fence line Do not install the operator on the public side of the property fence...

Страница 3: ...mproper and therefore dangerous 2 When using any electrical equipment observe some fundamental rules Do not touch the equipment with damp or humid hands or feet Do not install or operate the equipment...

Страница 4: ...ened and or closed Operator dimensions l w h in cm 40 X 3 5 16 X 3 5 16 102 X 8 5 X 8 5 47 1 2 X 3 5 16 X 3 5 16 121 X 3 X 8 5 Operator weight lb kg 19 8 6 Power voltage required VAC7 115 VAC 10 60 Hz...

Страница 5: ...luded see Figure 1 If you have ordered a kit a pair of operators you will have twice the quantity of parts listed below except where noted and you will also have a radio receiver and two transmitters...

Страница 6: ...h the 400 Operator The Manual Release mechanism is a key operated device that disengages or engages the hydraulic system of the 400 Operator When the hydraulic system is disengaged you can open and cl...

Страница 7: ...g steps 1 Attach the rear mounting bracket 2 Attach the mounting hardware 3 Attach the front mounting bracket 4 Attach the operator to the gate 5 Adjust the operator pressure ATTACH THE REAR MOUNTING...

Страница 8: ...ately 6mm Note Be sure that the operator is level and that the gate is against the close positive stop Hold the front mounting bracket flush against the gate Mark the location of the front mounting br...

Страница 9: ...RNING The piston should not bottom out in either direction Doing so will seriously damage the operator Be sure that the gate reaches the positive stop before the piston bottoms out Adjust the swivel j...

Страница 10: ...ate the control panel in the most convenient position possible considering the movement of the gate Figure 7 shows a basic layout for a two leaf gate with the 400 Operator Installing the control panel...

Страница 11: ...the 400 operator should bleed itself Running the operator should remove any air from the system If the operator runs smooth throughout the swing no attempt to further bleed the unit is necessary If t...

Страница 12: ...Page 12 November 2003 400 Operator And 455 D Control Panel Installation Manual EXPLODED VIEW 400 CBAC...

Страница 13: ...2 36 7039025 Washer Swivel 1 37 702201 Swivel Jam Nut 10mm 1 38 7073025 Swivel Joint 1 39 N A Star Washer 5mm 2 POS PART NO DESCRIPTION QTY 40 7119405 Protective Cover End Cap Plug 2 41 7019195 Tie Ro...

Страница 14: ...cal codes The installer should refer to the installation manual for a given operator for more information NOTE An installation is U L compliant only when you install the FAAC operators according to th...

Страница 15: ...eaf gate design be sure to connect its operator to Motor 1 In order to wire motor 2 in a bi parting system connect the white wire to terminal 4 on the J4 terminal strip the black wire to 5 the red wir...

Страница 16: ...ain power and send an activating signal to the operator The gate leaf or leaves should open If a gate leaf closes then you need to turn off the main power and reverse the connection of the red and bla...

Страница 17: ...he respective terminals OP_A and OP_B Partial Opening should illuminate only when an activating signal is sent for 2 and 1 gate leaves respectively STOP should be illuminated except when the stop butt...

Страница 18: ...he delayed leaf closes at the end of the closing time Page 18 November 2003 400 Operator And 455 D Control Panel Installation Manual opening and closing respectively are triggered Use the LEDs and the...

Страница 19: ...17 Additional Reversing Devices TX RX 1 2 1 2 3 4 5 19 17 12 19 17 Additional Reversing Devices TX RX 1 2 19 12 17 15 Additional Reversing Devices 8 7 Saf ety Loop Detector f or closing 1 2 3 4 5 RX 1...

Страница 20: ...the value that can be modified with keys and When you reach the last function press the F key to exit the program and the display resumes showing the status of the inputs The table on page 9 shows the...

Страница 21: ...ns as a standard indicator light lighted at opening and pause flashing at closing and off when gate closed Different figures correspond to timed activation of the output which can be used via a relay...

Страница 22: ...leaves begin the opening movement The movement stops automatically when the opening positive stop is reached and the display stops flashing LEARNING OF OPERATING TIMES WARNING During the learning pro...

Страница 23: ...e gate operator reaches its positive stop the operator will automatically shut off An open command must be given to start closing gate operator 2 When gate operator 2 reaches the position that you wan...

Страница 24: ...g Reversing Device s Warning Light Closed Opens both leaves and closes them after pause time Opens single leaf connected to Motor 1 and closes it after pause time No effect No effect No effect Off Ope...

Страница 25: ...ens single leaf connected to Motor 1 No effect opening is in hibited No effect opening is inhibited No effect opening is inhibited Off Opening Stops Stops Stops Stops gate closes when reversing device...

Страница 26: ...tential of traffic getting backed up This distance is affected by the size of the gate how often it is used and how fast the gate operates The operator you choose to install on your gate must be desig...

Страница 27: ...your reversing devices If no reversing devices are installed make sure a circuit is installed between appropriate terminals PROBLEM THE GATE DOES NOT FULLY OPEN OR CLOSE SOLUTION Increase the bypass...

Страница 28: ...or has been subject to misuse negligence or accident or has not been operated in accordance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions more sever...

Отзывы: