The FAAC recommended maintenance schedule varies 

according to the frequency of use of the operators, 

whether lightly used operators (once or twice an hour) 

or heavily used operators (many cycles per hour). 

Operators used in a humid/ salt air climate should 

follow the heavy duty use schedule. 

 

 Check the oil. 

 

To check the oil level correctly, remove the locking cap 

from the operator. The operator should be at least half 

full. 

 

  

Note: You will not be able to see the oil level. 

Use something flexible (i.e. A piece of stranded 

wire) to act as a dipstick. 

 

 If the operator is too full, it will bleed oil out the vent 

hole. 

 

  

Light duty use: check once per year 

 

Heavy duty use: check every 6 mo 

 

Change the oil. 

 

Changing the oil requires removing the operator from its 

installed position. Remove the locking cap and drain the 

oil out of the hole under the cap. Refill the operator with 

the proper new oil (see page 4). 

 

  

Light duty use: change every 4 yr 

 

Heavy duty use: change every 2 yr 

 

 Check the pressure settings. 

 

  

Light duty use: check once per year 

 

Heavy duty use: check every 6 mo 

 

 

T

HE

 455 D C

ONTROL

 P

ANEL

 

 
Keep the control panel free from spider webs, insects, etc. 

Otherwise, the control panel requires no maintenance. 

S

AFETY

 

IN

 G

ATE

 D

ESIGN

 

• 

A gate is a potential traffic hazard, so it is important 
that you locate the gate far enough away from the 

road to eliminate the potential of traffic getting 

backed up. This distance is affected by the size of 

the gate, how often it is used, and how fast the gate 

operates. 

 

• 

The operator you choose to install on your gate 
must be designed for the type and size of your gate 

and for the frequency with which you use the 

operator. 

 

• 

Your gate must be properly installed and must work 
freely in both directions 

before 

the automatic 

operator is installed. 

 

• 

An automatic operator should be installed on the 
inside of the property/fence line. Do not install the 

operator on the public side of the property/fence 

line. 

 

• 

Outward swinging gates with automatic operators 
should not open into a public area. 

 

• 

Pedestrians should not use a vehicular gate system. 
Prevent such inappropriate use by installing 

separate gates for pedestrians. 

 

• 

The operating controls for an automatic gate must 
be secured to prevent the unauthorized use of those 

controls. 

 

• 

The controls for an automatic gate should be 
located far enough from the gate so that a user 

cannot accidentally touch the gate when operating 

the controls. 

 

• 

Exposed, reachable pinch points on a gate are 
potentially hazardous and must be eliminated or 

guarded. 

 

• 

It is extremely unsafe to compensate for a damaged 
gate by over tightening a clutch or increasing 

hydraulic pressure. 

 

• 

An automatic gate operator should not be installed 
on a gate if people can reach or extend their arms 

or legs through the gate. Such gates should be 

guarded or screened to prevent such access. 

M

AINTENANCE

  

Page 26 

November, 2003 

400 Operator And  

455 D Control Panel Installation Manual  

Содержание 455 D

Страница 1: ...455 D Control Panel General Description 14 Installing the 455 D Control Panel 14 Connect the Main Power Supply 14 Connect the Operator to the Control Panel 15 Check the Motor s Direction of Rotation 1...

Страница 2: ...ons before the automatic operator is installed 4 An automatic operator should be installed on the inside of the property fence line Do not install the operator on the public side of the property fence...

Страница 3: ...mproper and therefore dangerous 2 When using any electrical equipment observe some fundamental rules Do not touch the equipment with damp or humid hands or feet Do not install or operate the equipment...

Страница 4: ...ened and or closed Operator dimensions l w h in cm 40 X 3 5 16 X 3 5 16 102 X 8 5 X 8 5 47 1 2 X 3 5 16 X 3 5 16 121 X 3 X 8 5 Operator weight lb kg 19 8 6 Power voltage required VAC7 115 VAC 10 60 Hz...

Страница 5: ...luded see Figure 1 If you have ordered a kit a pair of operators you will have twice the quantity of parts listed below except where noted and you will also have a radio receiver and two transmitters...

Страница 6: ...h the 400 Operator The Manual Release mechanism is a key operated device that disengages or engages the hydraulic system of the 400 Operator When the hydraulic system is disengaged you can open and cl...

Страница 7: ...g steps 1 Attach the rear mounting bracket 2 Attach the mounting hardware 3 Attach the front mounting bracket 4 Attach the operator to the gate 5 Adjust the operator pressure ATTACH THE REAR MOUNTING...

Страница 8: ...ately 6mm Note Be sure that the operator is level and that the gate is against the close positive stop Hold the front mounting bracket flush against the gate Mark the location of the front mounting br...

Страница 9: ...RNING The piston should not bottom out in either direction Doing so will seriously damage the operator Be sure that the gate reaches the positive stop before the piston bottoms out Adjust the swivel j...

Страница 10: ...ate the control panel in the most convenient position possible considering the movement of the gate Figure 7 shows a basic layout for a two leaf gate with the 400 Operator Installing the control panel...

Страница 11: ...the 400 operator should bleed itself Running the operator should remove any air from the system If the operator runs smooth throughout the swing no attempt to further bleed the unit is necessary If t...

Страница 12: ...Page 12 November 2003 400 Operator And 455 D Control Panel Installation Manual EXPLODED VIEW 400 CBAC...

Страница 13: ...2 36 7039025 Washer Swivel 1 37 702201 Swivel Jam Nut 10mm 1 38 7073025 Swivel Joint 1 39 N A Star Washer 5mm 2 POS PART NO DESCRIPTION QTY 40 7119405 Protective Cover End Cap Plug 2 41 7019195 Tie Ro...

Страница 14: ...cal codes The installer should refer to the installation manual for a given operator for more information NOTE An installation is U L compliant only when you install the FAAC operators according to th...

Страница 15: ...eaf gate design be sure to connect its operator to Motor 1 In order to wire motor 2 in a bi parting system connect the white wire to terminal 4 on the J4 terminal strip the black wire to 5 the red wir...

Страница 16: ...ain power and send an activating signal to the operator The gate leaf or leaves should open If a gate leaf closes then you need to turn off the main power and reverse the connection of the red and bla...

Страница 17: ...he respective terminals OP_A and OP_B Partial Opening should illuminate only when an activating signal is sent for 2 and 1 gate leaves respectively STOP should be illuminated except when the stop butt...

Страница 18: ...he delayed leaf closes at the end of the closing time Page 18 November 2003 400 Operator And 455 D Control Panel Installation Manual opening and closing respectively are triggered Use the LEDs and the...

Страница 19: ...17 Additional Reversing Devices TX RX 1 2 1 2 3 4 5 19 17 12 19 17 Additional Reversing Devices TX RX 1 2 19 12 17 15 Additional Reversing Devices 8 7 Saf ety Loop Detector f or closing 1 2 3 4 5 RX 1...

Страница 20: ...the value that can be modified with keys and When you reach the last function press the F key to exit the program and the display resumes showing the status of the inputs The table on page 9 shows the...

Страница 21: ...ns as a standard indicator light lighted at opening and pause flashing at closing and off when gate closed Different figures correspond to timed activation of the output which can be used via a relay...

Страница 22: ...leaves begin the opening movement The movement stops automatically when the opening positive stop is reached and the display stops flashing LEARNING OF OPERATING TIMES WARNING During the learning pro...

Страница 23: ...e gate operator reaches its positive stop the operator will automatically shut off An open command must be given to start closing gate operator 2 When gate operator 2 reaches the position that you wan...

Страница 24: ...g Reversing Device s Warning Light Closed Opens both leaves and closes them after pause time Opens single leaf connected to Motor 1 and closes it after pause time No effect No effect No effect Off Ope...

Страница 25: ...ens single leaf connected to Motor 1 No effect opening is in hibited No effect opening is inhibited No effect opening is inhibited Off Opening Stops Stops Stops Stops gate closes when reversing device...

Страница 26: ...tential of traffic getting backed up This distance is affected by the size of the gate how often it is used and how fast the gate operates The operator you choose to install on your gate must be desig...

Страница 27: ...your reversing devices If no reversing devices are installed make sure a circuit is installed between appropriate terminals PROBLEM THE GATE DOES NOT FULLY OPEN OR CLOSE SOLUTION Increase the bypass...

Страница 28: ...or has been subject to misuse negligence or accident or has not been operated in accordance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions more sever...

Отзывы: