Working with AC Power Supplies
Platform Guide: 1600, 3600, and 3900
6 - 3
Replacing a power supply
We recommend that you perform the power supply replacement on a
standby unit in a redundant system after halting it and powering the system
off. After you install the power supply in the standby system, force the
active system to fail over and install the power supply replacement in the
other unit of the redundant system.
Important
If the power supply is inserted with the power switch turned on, the power
supply cannot function, for safety reasons. If the power supply you have is in
this condition, turn off the power switch, remove the power supply, reinsert
it, and then turn the power switch on.
To replace a power supply
1. Make sure that the power switch on the power supply is turned off.
2. Disconnect the AC power cord from the power supply before
removing it from the unit.
3. The power supplies are held on the chassis by a screw. Loosen the
screw using a Phillips screwdriver.
4. Pull the old power supply out of the system.
5. Slide the new power supply into the power supply slot.
6. Tighten the screw into place using a Phillips screwdriver.
The power supply is connected to the system when you tighten the
screw completely.
7. Attach the power cord to the new power supply.
8. Turn the power switch on.
If the power supply was accidentally inserted while the power switch was
on, the power supply may not function properly. To correct this condition,
you must turn off the power switch, remove the power supply, reinsert it,
and then turn the power switch on before the power supply can function
properly.
Содержание BIG-IP 1600
Страница 1: ...Platform Guide 1600 3600 and 3900 MAN 0270 01 ...
Страница 2: ......
Страница 5: ...Table of Contents ...
Страница 6: ......
Страница 10: ...Table of Contents viii ...
Страница 12: ......
Страница 24: ...Chapter 1 1 12 ...
Страница 25: ...2 Installing the 1600 3600 3900 Platform Installing and connecting the hardware ...
Страница 26: ......
Страница 35: ...3 Operating the LCD Panel Introducing the LCD panel Using the LCD panel Navigating through the LCD menus ...
Страница 36: ......
Страница 44: ......
Страница 53: ...5 Using Always On Management Introducing Always On Management Accessing the AOM Command Menu ...
Страница 54: ......
Страница 59: ...6 Working with AC Power Supplies Reviewing maintenance options and operations ...
Страница 60: ......
Страница 64: ...Chapter 6 6 4 ...
Страница 65: ...7 Working with DC Power Supplies Reviewing maintenance options and operations ...
Страница 66: ......
Страница 70: ...Chapter 7 7 4 ...
Страница 71: ...8 Changing the Fan Tray Reviewing maintenance options and operations ...
Страница 72: ......
Страница 75: ...9 Working with Environmental Guidelines for the 1600 3600 and 3900 Platforms Environmental requirements ...
Страница 76: ......
Страница 79: ...10 Understanding Platform Airflow Platform airflow information ...
Страница 80: ......
Страница 82: ...Chapter 10 10 2 ...
Страница 84: ......
Страница 93: ...A Platform Specific Hazardous Substance Levels for China 1600 platform 3600 platform 3900 platform ...
Страница 94: ......
Страница 98: ...Appendix A A 4 ...
Страница 99: ...Glossary ...
Страница 100: ......
Страница 103: ...Index ...
Страница 104: ......