XN3 Installation and Operating Manual
13
3.3
Cable Entries
3.3.1
Typical Cable Entries and Connections
A typical XN3 enclosure is supplied with entries and connectors as shown in Figure
3.
•
Connections A-D are INTRINSICALLY SAFE outputs providing galvanically
isolated RF signals (see Section 3.10
for details), carried on conventional 50Ω
impedance N-type female connections. The N-type connections are the front
part of the bulkhead which transit through the enclosure and are approved as
part of the XN3 ATEX/IECEx certification.
•
Apply suitably assessed glands to cable entries (marked E and F) as appropriate
o
Thread maximum size is M25x1.5 or 3/4
” NPT depending
on customer
specification.
•
The position and configuration of cable entries and connections can vary
depending on the XN3 ordered. Mark off connections inside the junction box.
o
Remove cover plate and keep bolts for reassembly
o
When refitting cover plate, only use supplied bolts and tighten to torque
3.5Nm. Check seal position and condition.
o
Check with Extronics for more information if required.
Figures 3: XN3 entries and connectors