XN3 Installation and Operating Manual         

 

 

21 

4

 

Intended Purpose Usage 

 

The XN3 is built using modern components and is extremely reliable in operation. 
It  must  only  be  used  for  its  intended  purpose.  Please  note  that  the  intended 

purpose also includes compliance with the instructions issued by the manufacturer 
for installation, setting up and service.   

 
Any  other  use  is  regarded  as  conflicting  with  the  intended  purpose.  The 

manufacturer  is  not  liable  for  any  subsequent  damage  resulting  from  such 

inadmissible use. The user bears the sole risk in such cases. 
 

4.1

 

Transportation and Storage 

All XN3 devices must be so transported and stored that they are not subjected to 

any excessive mechanical stresses. 

 

4.2

 

Authorized Persons 

Only persons trained for the purpose are authorized to handle the XN3; they must 
be  familiar  with  the  unit  and  must  be  aware  of  the  regulation  and  provisions 

required  for  explosion  protection  as  well  as  the  relevant  accident  prevention 
regulations.  

 

4.3

 

Cleaning and Maintenance 

The XN3 and all its components require no maintenance. All work on the XN3 by 

personnel  who  are  not  expressly  qualified  for  such  activities  will  cause  the  Ex 
approval and the guarantee to become void. 

 

4.4

 

Cleaning and Maintenance Intervals 

The cleaning intervals depend on the environment where the system is installed.  

 

4.5

 

Aggressive substances and environments 

The  XN3  is  not  designed  to  encounter  aggressive  substances  or  environments, 
please be aware that additional protection may be required. 

 

4.6

 

Exposure to external stresses 

The XN3 is not designed to be subjected to excessive stresses e.g. vibration, heat 

or  impact.  Additional  protection  is  required  to  protect  against  these  external 
stresses. 

 

The XN3 will require additional protection if it is installed in a location where it may 
be subjected to damage. 

 
 

 

 
 

 
 

 
 

 

Содержание iWAP XN3

Страница 1: ...INSTALLATION AND OPERATING MANUAL...

Страница 2: ...3 and X124186 The Photograph on the front page shows the XN3 Aluminium Enclosure version For warranty information refer to Terms and Conditions at http www extronics com 2021 Extronics Limited This do...

Страница 3: ...Connector 16 3 7 Fuse Rating 16 3 8 External Overcurrent Protection 16 3 9 Data Connections 17 3 9 1 Copper Ethernet 17 3 9 2 Power Over Ethernet POE 17 3 9 3 Optical Fibre 17 3 9 4 Console Port 18 3...

Страница 4: ...NT2xx range of high quality rugged outdoor antennas Any antennas not listed in the Extronics range must be assessed by the user to ensure they meet the requirements for installation of non electrical...

Страница 5: ...losure shall only be with a damp cloth L quipement ne doit pas tre mont dans une zone l atmosph re haut d bit d air charg de poussi re En outre le nettoyage du bo tier ne doit tre effectu qu avec un c...

Страница 6: ...nstructed personnel in accordance with national legislation Warning The XN3 contains INTRINSICALLY SAFE circuits Warning The XN3 Intrinsically Safe RF output ports are located in the positions shown i...

Страница 7: ...N3 enclosure must be secured only with the bolts supplied and these must be tightened to the correct torque value See Section 3 2 2 for details Contact Extronics for replacement bolts Avertissements L...

Страница 8: ...or N type RF connectors Good manual handling practice should be followed Warning User access Normal user access to the enclosure is through the cover plate and junction box Avertissements Acc s utili...

Страница 9: ...rformed in accordance with IEC 60079 17 Important Before setting the units to work read the technical documentation carefully Important The latest version of the technical documentation or the corresp...

Страница 10: ...XN3 Installation and Operating Manual 10 3 Installation 3 1 Mounting Mount the XN3 enclosure to a suitable structure using the mounting points shown...

Страница 11: ...XN3 Installation and Operating Manual 11 Figure 1 Aluminium Enclosure Mounting Dimensions...

Страница 12: ...rise the cover apart as it may damage the sealing gasket 3 2 2 Closing the Enclosure Inspect the gasket to ensure its sealing integrity If the front cover gasket is damaged it must be replaced Check a...

Страница 13: ...rough the enclosure and are approved as part of the XN3 ATEX IECEx certification Apply suitably assessed glands to cable entries marked E and F as appropriate o Thread maximum size is M25x1 5 or 3 4 N...

Страница 14: ...g point situated within the junction box Figure 4 Removal of the front cover plate is required to access the area Before putting in service Perform applicable electrical safety checks Visually check i...

Страница 15: ...Installation and Operating Manual 15 3 5 Electrical Installation View inside junction box See Figure 6 and Table1 Figure 6 XN3 Internal Connections Showing All Options Interface Plate G F D E1 1 B E2...

Страница 16: ...e 1 XN3 Internal Connection Features 3 6 Power Supply Input Connector The mains power connection is a phoenix socket on the PCB The plug part is Phoenix contact 1795789 It requires a minimum tightenin...

Страница 17: ...plug as follows EIA 568B standard 3 9 2 Power Over Ethernet POE If Power Over Ethernet POE is used the format will depend on the access point installed in the XN3 Ensure that the correct Power Sourci...

Страница 18: ...ay use different formats 3 9 4 2 Mini USB 3 10 Intrinsically Safe RF Outputs Refer to Figure 8 for location of Intrinsically Safe RF outputs 3 10 1 Example of RF threshold power calculation The follow...

Страница 19: ...trinsically safe outputs Minimum IP54 connection Coaxial cable Notes Marking of iWAP XN3 must be observed when locating antenna in hazardous location Maintain 500Vrms isolation between conductive part...

Страница 20: ...via a length of coaxial cable If antennas are sited remotely from the XN3 flameproof enclosure any metallic parts of the antennas must be isolated from earth by 500Vr m s to prevent hazardous earth c...

Страница 21: ...familiar with the unit and must be aware of the regulation and provisions required for explosion protection as well as the relevant accident prevention regulations 4 3 Cleaning and Maintenance The XN3...

Страница 22: ...g nut 3 and repeat the process 5 Repeat for the other side and the other rail 6 This is how the assembly looks when completed 7 Place the iWAPX3 on a protective surface as shown 3 8 Align both rails o...

Страница 23: ...XN3 Installation and Operating Manual 23 6 Technical Data...

Страница 24: ...ambient temperature ranges may be specified depending on the service temperature of installed equipment Alternative coding when Extronics iSOLATE501 is installed for DC isolation AII 3 1 G Ex ec ia Ga...

Страница 25: ...temperature of installed equipment Alternative coding when Extronics iSOLATE501 is installed for DC isolation o Class I Zone 2 AEx ec iaGa nR IIC T6 Gc o Class II Zone 22 AEx iaDa tc IIIB T85o C Dc Al...

Страница 26: ...079 7 5th Ed Standard for Explosive Atmospheres Part 7 Equipment Protection by Increased Safety e 2017 02 24 UL 60079 11 Ed 6 Explosive Atmospheres Part 11 Equipment Protection by Intrinsic Safety i 2...

Страница 27: ...XN3 Installation and Operating Manual 27 9 EU Declaration of Conformity...

Страница 28: ...XN3 Installation and Operating Manual 28...

Отзывы: