VNR 100 • Configuration and Hardware Setup
13
3.
Click
Login
. The VNR 100 Recorder Settings page opens:
Network settings [eth0]
Recorder settings
User settings
Data disk
IP Address
Subnet Mask
Gateway
Serial
Controller IP
Controller port
MTU
New password
Confirm New password
192.168.254.254
255.255.255.0
192.168.254.253
192.168.254.254
5432
1500
1111999
mounted to /home/matrix_rec/Recording_Files
Disk free space: 19GB->98% used
formated to ext3
status:
Umount
Format
Apply Changes
Cancel Changes
Logout
VNMatrix recorder settings
Figure 11.
VNR 100 Web Page
IP Address and Subnet mask
— are assigned to the ETH0 NIC on the VNR100.
Gateway
— is the IP address of the gateway that is assigned to the ETH0 NIC on
the VNR100. If no gateway exists, the IP address should be the same as the system
contoller.
Controller IP Address
— is the IP address of the Enterprise Controller used to control
the VNR100.
Controller Port
— is the port number is used by all VN_Matrix devices to communicate
with the Enterprise Controller. The value should only be changed if the Enterprise
Controller has been configured to accept communications on a different port number.
Under normal circumstances the setting should remain at the default setting (5432).
Maximum Transmission Unit (MTU)
— is used to set the packet size, in bytes, that
is used to transmit data over the network. The default is 1500 bytes. This setting is
for advanced use only. Under normal circumstance do not change this value from the
default value. If the MTU value is incorrectly set, the MATRIX system may malfunction.
New password
— Change the default password for the config account if required. The
User account name cannot be changed.
Data (media) disk
—This area provides information about the media drive on the
VNR 100. For full instructions on replacing the media drive, please see the
VNR 100
Media Drive Replacement Kit Installation Guide
, at
www.extron.com
.
4.
Enter the
IP Address
,
Subnet Mask
, and
Gateway
address of the recorder in the
corresponding fields.
5.
Enter the
Controller IP
address,
Controller port
number and maximum
transmission unit (
MTU
) setting of the controller in the corresponding fields.
6.
Enter a
New password
and
Confirm New password
in the corresponding fields.
7.
Click
Apply Changes
to save the settings (or click
Cancel Changes
to exit without
saving the information).
NOTE:
There is no indication whether you have successfully connected to the
Enterprise Controller. To verify that the recorder has linked to the controller, you
must log on to the controller and ensure that the recorder is in the device list.