SMX System MultiMatrix Switcher • SIS Programming Guide
19
SIS Programming
Guide
The SMX uses SIS commands for operation and configuration. These
commands can be run from a PC connected to either of the SMX serial
ports or the Ethernet port. See
b
and
d
, and
f
on
for connection information.
NOTE:
The tables that begin on page 22 are a partial list of
(see the
SMX User Guide
for a complete list).
This section describes selected SIS Commands and includes:
•
•
SIS Overview
Network (Ethernet) Connections
1.
Open a TCP socket to port 23 using the SMX IP address
NOTE:
The factory default IP address is 192.168.254.254.
The SMX responds with a copyright message including the date,
the name of the product, firmware version, part number, and the
current date and time.
2.
If the SMX is not password-protected, the device is now ready to
accept SIS commands.
If the SMX is password-protected, enter the appropriate password.
If accepted, the SMX responds with
Login User
or
Login
Administrator
. If the password is not accepted, the
Password
prompt reappears.
Connection time-outs
The Ethernet link disconnects after a designated period of no
communications. By default, this time-out value is set to 5 minutes
but the value can be changed.
NOTE:
Extron recommends leaving the default time-out at 5
minutes and periodically issuing the
Query
(
Q
) command
to keep the connection active or disconnecting the socket
and reopening the connection when necessary.
Содержание MultiMatrix SMX System
Страница 1: ...Setup Guide 68 1452 50 Rev B 10 11 SMX System MultiMatrix Switcher Matrix Switcher ...
Страница 6: ...vi SMX System MultiMatrix Switcher Contents ...
Страница 45: ...39 SMX System MultiMatrix Switcher Reference Material Notes ...
Страница 46: ...40 SMX System MultiMatrix Switcher Reference Material ...