Communication and Control, cont’d
IPL T S Series • Communication and Control
4-14
Command
ASCII (T
elnet)
(host to unit)
URL Encoded (W
eb)
(host to unit)
Response
(unit to host)
Additional description
V
iew br
oadcast port
and MAC
E
PB
}
WPB
|
{port}*
X1*]
N
{port#} = UDP outgoing port,
X7!
*
X7@
= MAC addr
ess for UDP unicast transmissions.
N
Changes to the PB command become effective in kernel versions 1.53 or higher
.
Passwor
d and securit
y
settings
Set administrator
passwor
d
24
E
X3#
CA
}
W
X3#
CA
|
Ipa•
X4!]
Set the administrator access passwor
d
(
X3#
, 4 to 12 alphanumeric characters).
The passwor
d is case sensitive. Special
characters (spaces, symbols) ar
e not
allowed.
X4!
=
Passwor
d to display on
scr
een (r
esponse to passwor
d query).
When the IPL
T S unit connects to a host
device
via
RS-232,
the
passwor
d
(
X3#
),
itself,
is the r
esponse. When the connection is via
IP
,
X4!
is 4 asterisks (****) if a passwor
d has
been assigned, or it is an empty field (
)
if a passwor
d hasn’t been assigned.
Clear administrator
passwor
d
24
E
•CA
}
W%20CA
]
Ipa•
]
Clear/r
emove all passwor
ds (administrator
and user).
N
A
user password cannot be assigned if an administrator password does not exist. Also, if the administrator password is clear
ed, the user password is also clear
ed.
V
iew administrator
passwor
d
E
CA
}
WCA
|
X4!]
Set user passwor
d
14, 24
E
X3#
CU
}
W
X3#
CU
|
Ipu•
X4!]
Set the user passwor
d (
X3#
is 4 to 12
alphanumeric characters). The passwor
d is
case sensitive. Special characters (spaces,
symbols) ar
e not allowed.
X4!
=
Passwor
d
to display on scr
een.
N
A
user password cannot be assigned if an administrator password does not exist. Also, if the administrator password is clear
ed, the user password is also clear
ed.
Clear user passwor
d
24
E
•CU
}
W%20CU
|
Ipu•
]
This clears the user passwor
d only
.
V
iew user passwor
d
E
CU
}
WCU
|
X4!]
Query session’s
security level
E
CK
}
WCK
|
X5@
]
or
Pvl
X5@
]
For
X5@
11 = user
12 = administrator
Содержание Extron IPL T S4
Страница 1: ...IPL T S Series IP Link Ethernet Control Interfaces 68 1218 01 Rev D 12 08 ...
Страница 4: ...IPL T S Series ii ...
Страница 6: ...IPL T S Series Quick Start QS 2 Quick Start IPL T S Series cont d ...
Страница 24: ...Installation and Operation cont d IPL T S Series Installation and Operation 2 12 ...
Страница 70: ...Communication and Control cont d IPL T S Series Communication and Control 4 30 ...
Страница 75: ...IPL T S Series B Appendix B Glossary Glossary ...