Installation and Operation, cont’d

IPL T S Series • Installation

2-8

Factory default protocol for the control interface is: 

  •  RS-232
  •  9600 baud
  •  no parity
  •  8 data bits
  •  1 stop bit
  •  pacing = 0 ms
  •  handshaking = off

Communication to an attached device can be done through the IPL T S Series 

device’s default Web pages or by using Extron’s Simple Instruction Set (SIS

commands.  

The rear panel 9-pin D connector COM ports have the following pin assignments:

Pin

Function

RS-232

RS-422

RS-485

2

Receive Data/Receive Data -

RX

RX-

Data - 

(pins 2 + 3 tied)

3

Transmit Data/ Transmit Data -

TX

TX-

5

Signal Ground

GND

GND

GND

7

Request to Sent/Transmit Data +

RTS

TX+

Data + 

 

(pins 7 + 8 tied)

8

Clear to Send/Receive Data +

CTS

TX-

N

  The IPL T S1 uses RS-232 only. 

 

When using RS-485 with the connections indicated above, Data + can connect 
to either pin 7 or pin 8, and Data - can connect to either pin 2 or pin 3. 

 

For RS-232 communication, pins 7 and 8 (RTS and CTS) are optional.

 

9-Pin D Connector 

Pin Locations, Female

5

1

9

6

COM5

TX RX

TX RX

COM6

COM3

TX RX

TX RX

COM4

Tr

ansmit

Receiv

e

Ground 

Tr

ansmit

Receiv

e

Tr

ansmit

Receiv

e

Ground 

Tr

ansmit

Receiv

e

Tr

ansmit

Receiv

e

Ground 

Tr

ansmit

Receiv

e

COM1

TX RX

TX RX

COM2

IPL T S2

Connectors

IPL T S6

Connectors

Heat
Shrink

1/8”

(3 mm)

7/8”

(22 mm)

3/16”

(5 mm) Max.

5-pole Captive Screw

Connector

Figure 2-10 — 5-pin captive screw assignments

Содержание Extron IPL T S4

Страница 1: ...IPL T S Series IP Link Ethernet Control Interfaces 68 1218 01 Rev D 12 08 ...

Страница 2: ...enden sollten Sie alle Sicherheits und Bedienungsanleitungen genau durchlesen und verstehen Aufbewahren der Anleitungen Die Hinweise zur elektrischen Sicherheit des Produktes sollten Sie aufbewahren damit Sie im Bedarfsfall darauf zurückgreifen können Befolgen der Warnhinweise Befolgen Sie alle Warnhinweise und Anleitungen auf dem Gerät oder in der Benutzerdokumentation Keine Zusatzgeräte Verwende...

Страница 3: ...able protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which c...

Страница 4: ...IPL T S Series ii ...

Страница 5: ...eries unit COM1 LAN 00 05 A6 00 30 06 POWER 12V 5A MAX COM5 TX RX TX RX COM6 COM3 TX RX TX RX COM4 COM2 IPL T S6 Ethernet Control Interface Step 4 Connect RS 232 cables from the IPL T S Series unit to the audio video A V devices Step 5 Connect power cords and apply power in the following order output devices projectors monitors speakers IPL T S Series device PC or serial controller input devices D...

Страница 6: ...IPL T S Series Quick Start QS 2 Quick Start IPL T S Series cont d ...

Страница 7: ...Panel Features and Cabling 2 5 Power 2 6 Ethernet LAN 2 7 Serial Communication 2 7 Identification 2 9 Operation 2 9 Front panel indicators 2 9 Resetting the unit 2 10 Chapter Three Connection and Configuration 3 1 Connecting the Hardware 3 2 Ethernet connection 3 2 Serial connection 3 2 Setting the Internet Protocol IP Address 3 3 Setting the IP address using Global Configurator 3 4 Setting the IP...

Страница 8: ...mmand descriptions on the following pages 4 5 Customization 4 19 Custom Web pages 4 19 Server Side Includes SSI 4 19 Query string 4 20 Code examples 4 21 Example 1 4 21 Example 2 4 22 URL encoding 4 23 Reserved characters 4 23 Unsafe characters 4 24 Advanced Serial Port Control 4 24 Serial pass through redirect mode 4 24 Direct port access ports 2001 through 2006 4 25 Serial Bridging 4 26 Hardware...

Страница 9: ...IPL T S Series 1 Chapter One Introduction About This Manual About the IPL T S Series Interface Features ...

Страница 10: ...rolled devices IPL T S1 control interface PN 60 801 81 One bidrectional RS 232 serial port 7 25 MB of available flash memory Low profile form factor 1 0 H x 4 3 W x 3 0 D 2 5 cm x 10 9 cm x 7 6 cm IPL T S2 control interface PN 60 544 81 Two bidrectional RS 232 RS 422 or RS 485 serial ports 7 25 MB of available flash memory 1 7 H x 4 3 W x 3 0 D 4 3 cm x 10 9 cm x 7 6 cm IPL T S4 control interface ...

Страница 11: ...ter client communications protocol CO M 1 LA N UI D 09 30 12 05 2 PO WER 12 V 5A MA X CO M5 TX RX TX RX CO M2 CO M3 TX RX TX RX CO M4 CO M 2 TCP IP Network Lighting Control Ethernet VCR Remote User Control Administrator Monitoring Projector Extron IPL T S6 Ethernet Control Interface with GlobalViewer Software Projector RS 232 Codec Document Camera RS 232 DVD Laptop Figure 1 1 A typical IPL T S Ser...

Страница 12: ...limited entry to only pre designated functions while administrator access level permits full access to advanced settings Configuration utility Global Configurator software a free easy to use Windows based configuration utility makes product setup simple and intuitive no programming knowledge is required Extensive library of device drivers Device drivers allow Extron products to control various dis...

Страница 13: ...IPL T S Series 2 Chapter Two Installation and Operation Installation Overview Mounting the IPL T S Interface Rear Panel Features and Cabling Operation ...

Страница 14: ...t onto a rack 1 Elevated operating ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient Therefore consider installing the equipment in an environment compatible with the maximum ambient temperature specified by the manufacturer Tma 32 to 122 F 0 to 50 C 2 Reduced air flow Installation of the equipmen...

Страница 15: ...he rubber feet from the bottom of the IPL T S unit 2 Secure the underside of the unit on the rack shelf with two 4 40 x 3 16 screws in opposite diagonal corners 3 Install additional unit s or blank panel s on the rack shelf as desired 4 Insert the shelf into the rack at the desired location 5 Secure the shelf to the rack using the supplied mounting screws 2 4 40 x 3 16 Screws Use 2 mounting holes ...

Страница 16: ...ure mounting brackets to the unit with the supplied screws 3 Hold the unit with the attached brackets against the underside of the furniture Mark the hole locations of the bracket on the mounting surface 4 Drill 3 32 2 mm diameter pilot holes 1 4 6 3 mm deep in the underside of the mounting surface at the marked hole locations 5 Insert 8 wood screws into the four pilot holes Tighten each screw unt...

Страница 17: ... figures 2 4 2 5 2 6 2 7 for details on each model 12V 0 5 A LAN COM1 00 05 A6 00 00 01 1 3 2 4 6 10 Figure 2 4 IPL T S1 interface back panel COM1 LAN 00 05 A6 00 00 02 POWER 12V 5A MAX COM1 TX RX TX RX COM2 COM2 10 6 1 7 5 3 2 4 Figure 2 5 IPL T S2 interface back panel N The IPL T S2 allows for use of either the 9 pin D connector or the captive screw connector on COM1 or COM2 The 9 pin D connecto...

Страница 18: ... damage the power supply and the interface Identify the power cord negative lead by the ridges on the side of the cord SECTION A A Ridges Smooth Power Supply Output Cord A A 3 16 5 mm Max Ground 12 VDC External Power Supply 12 VDC 1 A AC Power Cord Orange Captive Screw Connector Power Supply Output Cord Figure 2 8 Power connector wiring N Do not tin the stripped power supply leads before installin...

Страница 19: ...range 1 white green 2 orange 2 green 3 white green 3 white orange 4 blue 4 blue 5 white blue 5 white blue 6 green 6 orange 7 white brown 7 white brown 8 brown 8 brown Figure 2 9 RJ 45 connector wiring d Link LED A lit green LED indicates a good LAN connection Serial Communication e Captive screw connector Plug a 3 5 mm 5 pole captive screw connector into this socket for serial ports 1 and 2 IPL T ...

Страница 20: ...X 5 Signal Ground GND GND GND 7 Request to Sent Transmit Data RTS TX Data pins 7 8 tied 8 Clear to Send Receive Data CTS TX N The IPL T S1 uses RS 232 only When using RS 485 with the connections indicated above Data can connect to either pin 7 or pin 8 and Data can connect to either pin 2 or pin 3 For RS 232 communication pins 7 and 8 RTS and CTS are optional 9 Pin D Connector Pin Locations Female...

Страница 21: ...ork equipment Check indicator LEDs on the PC laptop on the interface and on the network hub router etc to ensure that all the devices are plugged in and communicating The IPL T S interface is not ready to be configured see chapter 3 Connection and Configuration If connection or communication problems occur see Troubleshooting in chapter 4 If the troubleshooting tips do not help check with your loc...

Страница 22: ...g serial port is ready to send data f CTS LEDs A green LED indicates that the device controlled by the corresponding serial port is ready to accept data g ACT Activity LED A yellow LED indicates that data is being sent received h LINK LED A green LED indicates that the unit is connected to an active network i 100 LED A green LED indicates that the connection speed is 100 Mbps If the LED is not lit...

Страница 23: ...p volume power up down delay auto power down and misc options This does not affect an optional MLS switcher however Clears driver port associations and port configurations IR RS 232 Removes button configurations Resets all IP options Removes scheduling settings Removes clears all files from switcher The Reset LED flashes 4 times in quick succession during the reset Reset Mode Comparison Summary Mo...

Страница 24: ...Installation and Operation cont d IPL T S Series Installation and Operation 2 12 ...

Страница 25: ... Chapter Three Connection and Configuration Connecting the Hardware Setting the Internet Protocol IP Address Configuration using Global Configurator Configuration using Embedded Web Pages Configuration using DataViewer ...

Страница 26: ...ne end of a CAT 5 straight through Ethernet cable into the rear panel Ethernet connector on the IPL T S unit Refer to figure 2 9 in chapter 2 for RJ 45 connector wiring information 2 Plug the other end of the Ethernet cable into a network switch or hub connected to an Ethernet LAN or to the Internet 3 From your PC launch a Web browser and type in the IP address previously set up on the IPL T S if ...

Страница 27: ... default IP address of 192 168 254 254 This IP address must be changed to an address that will operate on your local network There are three ways to change the IP address setting Add Device Auto Config IP option in Global Configurator IPL T S unit s embedded Web pages Address Resolution Protocol ARP command Before you begin 1 Obtain a valid IP address for your IPL T S Series device from your A V s...

Страница 28: ... project file and provides an illustrated version of the procedure below The IPL T S unit must be physically connected to the network at its factory default IP address To set an IP address with a GC project file open 1 From the Edit menu select Add Device The Add Device dialog box opens see figure 3 4 2 Select the appropriate device type ex IPL T S4 in the IP Link Device drop down list 3 Enter the...

Страница 29: ...Ethernet crossover cable between the device and a local PC 2 On the PC locate the TCP IP Properties dialog box On Windows XP the TCP IP Properties dialog box is found at Start My Network Places right click to Properties Local Area Connection right click to Properties Internet Protocol TCP IP Properties 3 Record the current IP address subnet mask default gateway and DHCP settings You will need this...

Страница 30: ... field and press the Enter key The IPL T S unit s embedded Web page is displayed 8 Click the Configuration tab 9 Change the IP Address and Subnet Mask fields to the desired IP address and subnet mask 10 Click the Submit button The new IP address and subnet mask are assigned to the device and the Web browser connection is immediately lost The device with its new IP address and subnet mask is now re...

Страница 31: ... address using the ARP command An IPL T S unit s IP address can be set using the DOS Address Resolution Protocol ARP command The IPL T S unit must be physically connected to the network at its factory default IP address To set an IP address using the ARP command 1 Open a command prompt window on a local PC On Windows XP a command prompt window can be found at Start All Programs Accessories Command...

Страница 32: ...ning A V control and monitoring system functionality from an easy to use graphical user interface It s simple enough to be used for configuring a single room controller yet powerful enough to facilitate building a Web based asset management and remote monitoring system for hundreds of A V devices in multiple locations Serial ports on the IPL T S Series devices can be configured using GC Global Con...

Страница 33: ...eries serial control ports See the Global Configurator help file for instructions on how to Download device drivers Start Global Configurator Create a GC project file Add and configure IPL T S Series and A V devices Configuration using Embedded Web Pages Each IPL T S unit contains an on board Web server with interactive pages that can be used to configure the device Web server pages are described ...

Страница 34: ...pages 1 Open a Web browser on a local PC 2 Enter the device s IP address in the browser s Address field and press the Enter key If the device is password protected you will be prompted for a password Figure 3 9 Web server Password dialog box 3 Enter the appropriate administrator or user password 4 Click OK The System Status page opens Figure 3 10 Web server System Status screen ...

Страница 35: ...IP Settings Unit Name DHCP setting IP Address Gateway IP Address Subnet Mask and MAC Address Serial Port Settings For each port Port number Port Type Baud Rate Data Bits Parity Stop Bits and Flow Control Figure 3 11 System Status screen Configuration page The Configuration page has five sub pages which are described below System Settings The System Settings page grants access to view and change th...

Страница 36: ...t number use a radio button to select the desired port Port type RS 232 default RS 422 4S 485 Baud rate 300 600 1200 1800 2400 3600 4800 7200 9600 default 14400 19200 28800 38400 57600 115200 Parity 7 8 default Stop bits 1 default 2 Flow control None default Hardware Software Serial Bridging On Off default Remote IP Address view the remote IP address Remote TCP Port view the remote TCP port Figure...

Страница 37: ...he embedded Web pages only allow you to make edits to existing e mail alert settings The Email Alerts page allows you to Edit your network s mail server connection information Edit e mail addresses of those you wish to receive e mail alerts Select the desired e mail delivery files Fields include Mail IP Address the network s mail server IP address Domain Name the network s mail server domain name ...

Страница 38: ...irmware level and provides the capability to browse to and upload a new firmware file Figure 3 16 Firmware Upgrade screen File Management page The File Management page allows you to create directories as well as upload use and delete custom Web pages Use the Add Dir Browse Upload Files and Delete buttons to upload and manage your custom Web pages Figure 3 17 File Management screen ...

Страница 39: ... configurations and formats With the DataViewer Control Toolbar and Shift Toolbar you can customize up to 20 shortcut keys Shortcut keys can be used to automate repetitive communications tasks DataViewer is ideal for troubleshooting device protocols and determining device timing DataViewer is available free from www extron com To download DataViewer 1 Open an Internet browser and advance to www ex...

Страница 40: ...e s IP address in the Hostname IP Address field 4 Click OK Figure 3 19 Communication Setup dialog box The DataViewer application opens see figure 3 16 See the DataViewer help file for information on sending commands to the IPL T S Series device and viewing the responses in the DataViewer user interface ...

Страница 41: ...IPL T S Series 4 Chapter Four Communication and Control Programmer s Guide for Telnet and Web Browsers Customization Advanced Serial Port Control Troubleshooting ...

Страница 42: ...ncoded When these commands are used through a Web browser the URL reference is used below to shorten the examples This would in practice be the full URL of the control interface and Web page reference including all path information For example http 192 168 100 10 myform htm To send any of the commands using a Web browser you need to prefix them with the full URL followed by cmd See URL Encoding la...

Страница 43: ... xx xx xx xx X1 Subnet mask xxx xxx xxx xxx Leading zeros in each of four fields are optional in setting values and are suppressed in returned values X2 Time in tens of milliseconds to wait between characters coming into a serial port before terminating default 2 20 ms max 32767 X2 Parameter to set either Length of message to receive or Delimiter value If length delimited use xxL where xx is the l...

Страница 44: ... event data can be inserted into the transmit buffer X5 ASCII digit s representing numeric value of data element read from event buffer Leading zeros are suppressed X6 Time in seconds to keep sending the broadcast message 0 255 default 10 X6 The number of seconds before timeout on IP connections min 1 max 65000 default 30 300 seconds If no data is received during the timeout period the Ethernet co...

Страница 45: ...e to the host E12 Invalid port number E13 Invalid parameter E14 Not valid for this configuration E17 System timed out E22 Busy E24 Privilege violation E25 Device not present E26 Maximum number of connections exceeded E27 Invalid event number E28 Bad filename file not found References to errors at command descriptions on the following pages 13 Commands that give an E13 invalid parameter error 24 Co...

Страница 46: ...ital L The response includes leading zeros L Length of the message to be received D Delimiter value byte count for L or a single ASCII character expressed in decimal form for D Byte count can be from 0 to 32767 default 0 The ASCII decimal delimiter value can be from 0 to 00255 default the byte count Examples A 3 byte length 3L A delimiter of ASCII 0A 10D N X1 X2 X2 is optional X1 is optional only ...

Страница 47: ... X2 X2 X2 X2 Configure mode 24 E X X2 CY W X 2A X2 CY Cpn X Cty X2 View mode E X CY W X CY X2 Configure flow control E X X3 X3 CF W X 2A X3 2C X3 CF Cpn X Cfl X3 X3 View flow control E X CF W X CF X3 X3 Configure receive timeout 24 E X X1 X2 X2 X2 CE W X 2A X1 2A X2 2A X2 2A X2 CE Cpn X Cce X1 X2 X2 X2 Set the time to wait X1 waiting time in tens of ms until receipt of the first response character...

Страница 48: ...nected via Ethernet If the IPL T S device is connected via RS 232 protocol only the global timeout commands apply and any commands involving X6 return the E13 error response View current connection port timeout E 0TC W0TC X6 Set global IP port timeout E 1 X6 TC W1 2A X6 TC Pti1 X6 The global port timeout is the default timeout period for all Telnet sessions X6 IP connection timeout period in secon...

Страница 49: ...ponss from 2Q 3Q 4Q Show the bootstrap factory installed and updated firmware versions See 2Q 3Q and 4Q below Example 0Q 0Q 1 03 1 00 1 18 IPL Series Thu 20 Jan 2005 09 41 47 GMT 1 01 1 31 IPL Series Tue 14 Jun 2005 00 54 58 GMT Query bootstrap firmware version 2Q 2Q X1 or Ver02 X1 The bootstrap firmware is not user replaceable but you may need this information during troubleshooting Example 2Q 2Q...

Страница 50: ...ions Query user memory usage 4I 4I bytes used out of of kbytes or Inf04 bytes used out of of kbytes Show amount of user memory used and total available user memory Example 4I 4I 217856 Bytes Used out of 7232 KBytes E mail Configure e mail events mailbox 24 E X4 X4 X4 CR W X4 2C X4 2C X4 CR Ipr X4 X4 X4 X4 e mail event number 1 64 X4 e mail recipient s address e g JDoe extron com for the person to ...

Страница 51: ...ommand N If file X4 eml is not found when the SM command is executed the MLC sends a default e mail message Set e mail server IP address and user domain name 24 E X1 X1 X7 X7 CM W X1 2C X1 2C X7 2C X7 2C CM Ipm X1 X1 X7 X7 X1 IP address xxx xxx xxx xxx Leading zeros are optional in setting values Leading zeros are suppressed in returned values X1 E mail domain name e g extron com X7 An e mail acco...

Страница 52: ... Set DHCP off 24 E 0 DH W0DH Idh0 N Changing DHCP from on to off also resets the IP address to the factory default 192 168 254 254 View DHCP mode E DH WDH X X 0 off or 1 on Set IP address 24 E X1 CI W X1 CI Ipi X1 X1 IP address xxx xxx xxx xxx Leading zeros in each of the four fields are optional in setting values View IP address E CI W CI X1 Leading zeros in each of the four fields are suppressed...

Страница 53: ...e Verbose mode creates more network traffic than usual which can slow down network performance Verbose mode is usually enabled for troubleshooting and disabled for daily use For a direct RS 232 connection the controller is set for verbose mode by default When the IPL T S device is connected via Ethernet verbose mode is disabled by default in order to reduce the amount of communication traffic on t...

Страница 54: ...ction is via IP X4 is 4 asterisks if a password has been assigned or it is an empty field if a password hasn t been assigned Clear administrator password 24 E CA W 20CA Ipa Clear remove all passwords administrator and user N A user password cannot be assigned if an administrator password does not exist Also if the administrator password is cleared the user password is also cleared View administrat...

Страница 55: ...isable the port by setting it to 0 Set Telnet port map 24 E port MT W port MT Pmt port Select a number for the port that will not conflict with any other ports Reset Telnet port map 24 E 23MT W23MT Pmt00023 This resets the Telnet port to port 23 Disable Telnet port 24 E 0MT W0MT Pmt00000 Setting the port number to 0 disables the port View Telnet port map E MT WMT port Set Web port map 24 E port MH...

Страница 56: ...irectories created in the IPL T S device may have the same names Example E majordirectory subdirectory next level CJ Wmajordirectory 2F subdirectory 2F next level 2F CJ Dir majordirectory subdirectory next level In this case the path is majordirectory subdirectory The directory that was just created or changed to is called next level Example E custompages HTMLfiles CJ Wcustompages 2F HTMLfiles 2FC...

Страница 57: ...Use a POST command on port 80 by the delimited data to be written to the flash file memory Retrieve file from user flash memory Send a page GET on port 80 followed by WSF responds with raw unprocessed data in file Example http 192 168 254 254 mypage html cmd WSF data from the file mypage html Reset zap erase commands Erase all files from flash memory 24 E ZFFF W ZFFF pf Zpf Reset all device settin...

Страница 58: ...factory default however the firmware version remains the same This includes all settings adjustments PINs the IP address and subnet mask Files in flash memory are also erased by this command The IP address is reset to 192 168 254 254 the subnet mask is reset to 255 255 0 0 This command is identical to reset mode 5 discussed in Resetting the Unit in chapter 2 N Unlike various PC operating systems a...

Страница 59: ... Web server to dynamically generate data for a Web page whenever requested SSIs typically use Extron s Simple Instruction Set SIS to communicate commands to the products or to attached control devices Using SSIs you can design and display custom pages with the IPL T S information provided by the SIS commands The basic format for an Extron SSI command is echo var x Where x is the SIS command to be ...

Страница 60: ...server to tell it which Web page to return to the browser The portion of the URL after the question mark is the query string which contains the SIS command that the IPL T S interface removes and executes As with SSI formatted commands query strings can use any valid SIS command either host or remote The query string in the figure below turns off DHCP on the IP Link device a href index html Starts ...

Страница 61: ...e document showing Server Side Includes The host SSI commands in the figure above request the product name product description and product part number of an IPL T S interface The remote SSI commands request the part number connection information and firmware version of an attached serial device html head title Example 1 title head h2 b HTML Example 1 h2 b body The following lines demonstrate how t...

Страница 62: ...ring can be used to build a Web page that can control a device html head title Example 2 title head h2 b HTML Example 2 b h2 body The following lines demonstrate how to send commands to RS 232 Comm Port 1 of an IPLink Product p a href index html cmd W01RS 1 Select Input 1 a br a href index html cmd W01RS 2 Select Input 2 a p body html Figure 4 7a HTML source code showing multiple hyperlinks using ...

Страница 63: ... to ensure compatibility and functionality with most Internet browsers As a general rule use the URL hexadecimal encoding method shown on the following page when these characters appear in your URLs The following types of characters do not require encoding in a URL Alphanumerics Special characters Reserved characters 0 9 a z A Z _ _ When used for their reserved purposes these characters do not req...

Страница 64: ...ymbol Greater than symbol Left curly brace Right curly brace Vertical bar pipe Backslash Caret Tilde Left square bracket Right square bracket Grave accent 20 23 22 3C 3E 25 7B 7D 7C 5C 5E 7E 5B 5D 60 Hex 32 35 123 125 124 92 94 126 91 93 96 34 60 62 37 Dec Advanced Serial Port Control If serial setup configurations are required the following options provide advanced methods for communicating seria...

Страница 65: ...et SIS commands earlier in this chapter for detailed command descriptions Direct port access ports 2001 through 2006 Direct port access allows a direct one to one connection to any of the serial ports using a TCP IP connection When a TCP session is initiated to port 2001 COM1 through port 2006 COM6 all data sent and received passes directly to and from that port without any processing Set serial p...

Страница 66: ...ng Serial bridging mode allows you to pass serial data between two COM ports through an Ethernet port creating a virtual serial connection over a LAN To use serial bridging two IPL T S devices one local and one remote must be enabled to communicate with each other providing PC or controller access to a remote A V device Hardware connection To set up the hardware for serial bridging 1 Verify that t...

Страница 67: ...configuration To allow both IPL T S units to communicate together you must configure unit 2 to communicate with unit 1 N If a driver was previously loaded onto your IPL T S device COM port s using Global Configurator serial bridging disables it To configure unit 2 to communicate with unit 1 1 Enter the IP address of unit 2 in the Internet browser s Address field at the top of the screen and press ...

Страница 68: ...rojectors the IPL T S interface and the control devices PC laptop etc If the output A V device cannot be remotely controlled check the following Power connections 1 Ensure that all devices are plugged in 2 Make sure that each device is receiving power The interface s front panel Power LED lights if the device is receiving power Data connections 1 Check the cabling connections and make adjustments ...

Страница 69: ...check with your system administrator b Make sure your PC does not have a software firewall program that might block the IP address of the unit 3 If contact is established with the unit but the unit s Web pages cannot be accessed by your Web browser verify in the Options or Preferences menu that your Web browser is configured for direct network connection and is not set up to use a proxy server If ...

Страница 70: ...Communication and Control cont d IPL T S Series Communication and Control 4 30 ...

Страница 71: ...IPL T S Series A Appendix A Specifications Part Numbers Accessories Specifications Part Numbers and Accessories ...

Страница 72: ... S1 1 9 pin male D IPL T S2 2 9 pin male D and 1 3 5 mm captive screw connector 5 pole IPL T S6 2 9 pin male D and 1 3 5 mm captive screw connector 10 pole IPL T S4 4 9 pin male D Baud rate and protocol 300 to 115200 baud Default settings adjustable 9600 baud 8 data bits 1 stop bit no parity Pin configurations Serial 9 pin D IPL T S1 RS 232 2 RX 3 TX 5 GND 7 RTS 8 CTS Serial 9 pin D IPL T S2 IPL T...

Страница 73: ...7 01 Enclosure type Metal Enclosure dimensions IPL T S1 1 0 H x 4 3 W x 3 0 D quarter rack wide 2 5 cm H x 10 9 cm W x 7 6 cm D Depth excludes connectors All other models 1 7 H x 4 3 W x 3 0 D 1U high quarter rack wide 4 3 cm H x 10 9 cm W x 7 6 cm D Depth excludes connectors Product weight 0 7 lbs 0 3 kg Shipping weight 2 lbs 1 kg Vibration ISTA 1A in carton International Safe Transit Association...

Страница 74: ...ubber feet 4 Velcro industrial strength strip Captive screw connector female 3 5 mm 5 pole 10 319 10 Captive screw connector female 3 5 mm 2 pole 10 319 05 Captive screw connector female 3 5 mm 2 pole orange 10 702 10LF Tweeker IPL T S Series Setup Guide Optional accessories Accessories Part number RSF 123 1U 3 5 VersaTools Rack Shelf Kit 60 190 20 RSU 129 11U 9 5 Universal Rack Shelf Kit 60 190 0...

Страница 75: ...IPL T S Series B Appendix B Glossary Glossary ...

Страница 76: ...such as Netscape Navigator version 6 0 or higher or Internet Explorer version 5 5 or higher can be used but if using Internet Explorer you must also have Microsoft Script version 5 6 or higher DHCP is the Dynamic Host Configuration Protocol DHCP which is a standardized communications protocol that enables network administrators to locally and automatically manage the assignment of IP addresses in ...

Страница 77: ...ng device router hub interface etc is connected to the Internet a table see ARP associates the device s IP address to its corresponding physical MAC address on the LAN Pass through allows control systems to work with the IPL T S interface and provides a link between two ports Ping is a utility that tests network connections It is used to determine if the host has an operating connection and is abl...

Страница 78: ... Dubai This Limited Warranty does not apply if the fault has been caused by misuse improper handling care electrical or mechanical abuse abnormal operating conditions or non Extron authorized modification to the product If it has been determined that the product is defective please call Extron and ask for an Applications Engineer at 714 491 1500 USA 31 33 453 4040 Europe 65 6383 4400 Asia or81 3 3...

Страница 79: ...7 FAX Extron Europe 800 3987 6673 Inside Europe Only 31 33 453 4040 31 33 453 4050 FAX Extron Asia 800 7339 8766 Inside Asia Only 65 6383 4400 65 6383 4664 FAX Extron Japan 81 3 3511 7655 81 3 3511 7656 FAX Extron China 400 883 1568 Inside China Only 86 21 3760 1568 86 21 3760 1566 FAX Extron Middle East 971 4 2991800 971 4 2991880 FAX 2008 Extron Electronics All rights reserved ...

Отзывы: