background image

This symbol is intended to alert the user of important operating and maintenance
(servicing) instructions in the literature provided with the equipment.

This symbol is intended to alert the user of the presence of uninsulated dangerous
voltage within the product's enclosure that may present a risk of electric shock.

Caution

Read

 

Instructions • 

Read and understand all safety and operating instructions before using the

equipment.

Retain Instructions • 

The safety instructions should be kept for future reference.

Follow Warnings • 

Follow all warnings and instructions marked on the equipment or in the user

information.

Avoid Attachments • 

Do not use tools or attachments that are not recommended by the equipment

manufacturer because they may be hazardous.

Warning

Power sources • 

This equipment should be operated only from the power source indicated on the

product. This equipment is intended to be used with a main power system with a grounded
(neutral) conductor. The third (grounding) pin is a safety feature, do not attempt to bypass or
disable it.

Power disconnection • 

To remove power from the equipment safely, remove all power cords from

the rear of the equipment, or the desktop power module (if detachable), or from the power
source receptacle (wall plug).

Power cord protection • 

Power cords should be routed so that they are not likely to be stepped on or

pinched by items placed upon or against them.

Servicing • 

Refer all servicing to qualified service personnel. There are no user-serviceable parts

inside. To prevent the risk of shock, do not attempt to service this equipment yourself because
opening or removing covers may expose you to dangerous voltage or other hazards.

Slots and openings • 

If the equipment has slots or holes in the enclosure, these are provided to

prevent overheating of sensitive components inside. These openings must never be blocked by
other objects.

Lithium battery • 

There is a danger of explosion if battery is incorrectly replaced. Replace it only

with the same or equivalent type recommended by the manufacturer. Dispose of used batteries
according to the manufacturer's instructions.

Ce symbole sert à avertir l’utilisateur que la documentation fournie avec le matériel
contient des instructions importantes concernant l’exploitation et la maintenance
(réparation).

Ce symbole sert à avertir l’utilisateur de la présence dans le boîtier de l’appareil de
 tensions dangereuses non isolées posant des risques d’électrocution.

Attention

Lire les instructions• 

Prendre connaissance de toutes les consignes de sécurité et d’exploitation avant

d’utiliser le matériel.

Conserver les instructions• 

Ranger les consignes de sécurité afin de pouvoir les consulter à l’avenir.

Respecter les avertissements • 

Observer tous les avertissements et consignes marqués sur le matériel ou

présentés dans la documentation utilisateur.

Eviter les pièces de fixation • 

Ne pas utiliser de pièces de fixation ni d’outils non recommandés par le

fabricant du matériel car cela risquerait de poser certains dangers.

Avertissement

Alimentations• 

Ne faire fonctionner ce matériel qu’avec la source d’alimentation indiquée sur

l’appareil. Ce matériel doit être utilisé avec une alimentation principale comportant un fil de
terre (neutre). Le troisième contact (de mise à la terre) constitue un dispositif de sécurité :
n’essayez pas de la contourner ni de la désactiver.

Déconnexion de l’alimentation• 

Pour mettre le matériel hors tension sans danger, déconnectez tous

les cordons d’alimentation de l’arrière de l’appareil ou du module d’alimentation de bureau (s’il
est amovible) ou encore de la prise secteur.

Protection du cordon d’alimentation • 

Acheminer les cordons d’alimentation de manière à ce que

personne ne risque de marcher dessus et à ce qu’ils ne soient pas écrasés ou pincés par des
objets.

Réparation-maintenance • 

Faire exécuter toutes les interventions de réparation-maintenance par un

technicien qualifié. Aucun des éléments internes ne peut être réparé par l’utilisateur. Afin
d’éviter tout danger d’électrocution, l’utilisateur ne doit pas essayer de procéder lui-même à ces
opérations car l’ouverture ou le retrait des couvercles risquent de l’exposer à de hautes tensions
et autres dangers.

Fentes et orifices • 

Si le boîtier de l’appareil comporte des fentes ou des orifices, ceux-ci servent à

empêcher les composants internes sensibles de surchauffer. Ces ouvertures ne doivent jamais
être bloquées par des objets.

Lithium Batterie • 

Il a danger d'explosion s'll y a remplacment incorrect de la batterie. Remplacer

uniquement avec une batterie du meme type ou d'un ype equivalent recommande par le
constructeur. Mettre au reut les batteries usagees conformement aux instructions du fabricant.

Safety Instructions • English

Consignes de Sécurité • Français

Sicherheitsanleitungen • Deutsch

Dieses Symbol soll dem Benutzer in der im Lieferumfang enthaltenen
Dokumentation besonders wichtige Hinweise zur Bedienung und Wartung
(Instandhaltung) geben.

Dieses Symbol soll den Benutzer darauf aufmerksam machen, daß im Inneren des
Gehäuses dieses Produktes gefährliche Spannungen, die nicht isoliert sind und
die einen elektrischen Schock verursachen können, herrschen.

Achtung

Lesen der Anleitungen 

• Bevor Sie das Gerät zum ersten Mal verwenden, sollten Sie alle Sicherheits-und

Bedienungsanleitungen genau durchlesen und verstehen.

Aufbewahren der Anleitungen 

• Die Hinweise zur elektrischen Sicherheit des Produktes sollten Sie

aufbewahren, damit Sie im Bedarfsfall darauf zurückgreifen können.

Befolgen der Warnhinweise 

• Befolgen Sie alle Warnhinweise und Anleitungen auf dem Gerät oder in

der Benutzerdokumentation.

Keine Zusatzgeräte 

• Verwenden Sie keine Werkzeuge oder Zusatzgeräte, die nicht ausdrücklich vom

Hersteller empfohlen wurden, da diese eine Gefahrenquelle darstellen können.

Vorsicht

Stromquellen

 • Dieses Gerät sollte nur über die auf dem Produkt angegebene Stromquelle betrieben

werden. Dieses Gerät wurde für eine Verwendung mit einer Hauptstromleitung mit einem
geerdeten (neutralen) Leiter konzipiert. Der dritte Kontakt ist für einen Erdanschluß, und stellt
eine Sicherheitsfunktion dar. Diese sollte nicht umgangen oder außer Betrieb gesetzt werden.

Stromunterbrechung 

• Um das Gerät auf sichere Weise vom Netz zu trennen, sollten Sie alle

Netzkabel aus der Rückseite des Gerätes, aus der externen Stomversorgung (falls dies möglich
ist) oder aus der Wandsteckdose ziehen.

Schutz des Netzkabels 

• Netzkabel sollten stets so verlegt werden, daß sie nicht im Weg liegen und

niemand darauf treten kann oder Objekte darauf- oder unmittelbar dagegengestellt werden
können.

Wartung 

• Alle Wartungsmaßnahmen sollten nur von qualifiziertem Servicepersonal durchgeführt

werden. Die internen Komponenten des Gerätes sind wartungsfrei. Zur Vermeidung eines
elektrischen Schocks versuchen Sie in keinem Fall, dieses Gerät selbst öffnen, da beim Entfernen
der Abdeckungen die Gefahr eines elektrischen Schlags und/oder andere Gefahren bestehen.

Schlitze und Öffnungen 

• Wenn das Gerät Schlitze oder Löcher im Gehäuse aufweist, dienen diese

zur Vermeidung einer Überhitzung der empfindlichen Teile im Inneren. Diese Öffnungen dürfen
niemals von anderen Objekten blockiert werden.

Litium-Batterie 

• Explosionsgefahr, falls die Batterie nicht richtig ersetzt wird. Ersetzen Sie

verbrauchte Batterien nur durch den gleichen oder einen vergleichbaren Batterietyp, der auch
vom Hersteller empfohlen wird. Entsorgen Sie verbrauchte Batterien bitte gemäß den
Herstelleranweisungen.

Este símbolo se utiliza para advertir al usuario sobre instrucciones importantes de
operación y mantenimiento (o cambio de partes) que se desean destacar en el
contenido de la documentación suministrada con los equipos.

Este símbolo se utiliza para advertir al usuario sobre la presencia de elementos con
voltaje peligroso sin protección aislante, que puedan encontrarse dentro de la caja
o alojamiento del producto, y que puedan representar riesgo de electrocución.

Precaucion

Leer las instrucciones • 

Leer y analizar todas las instrucciones de operación y seguridad, antes de usar

el equipo.

Conservar las instrucciones • 

Conservar las instrucciones de seguridad para futura consulta.

Obedecer las advertencias • 

Todas las advertencias e instrucciones marcadas en el equipo o en la

documentación del usuario, deben ser obedecidas.

Evitar el uso de accesorios • 

No usar herramientas o accesorios que no sean especificamente

recomendados por el fabricante, ya que podrian implicar riesgos.

Advertencia

Alimentación eléctrica • 

Este equipo debe conectarse únicamente a la fuente/tipo de alimentación

eléctrica indicada en el mismo. La alimentación eléctrica de este equipo debe provenir de un
sistema de distribución general con conductor neutro a tierra. La tercera pata (puesta a tierra) es
una medida de seguridad, no puentearia ni eliminaria.

Desconexión de alimentación eléctrica • 

Para desconectar con seguridad la acometida de

alimentación eléctrica al equipo, desenchufar todos los cables de alimentación en el panel trasero
del equipo, o desenchufar el módulo de alimentación (si fuera independiente), o desenchufar el
cable del receptáculo de la pared.

Protección del cables de alimentación • 

Los cables de alimentación eléctrica se deben instalar en

lugares donde no sean pisados ni apretados por objetos que se puedan apoyar sobre ellos.

Reparaciones/mantenimiento • 

Solicitar siempre los servicios técnicos de personal calificado. En el

interior no hay partes a las que el usuario deba acceder. Para evitar riesgo de electrocución, no
intentar personalmente la reparación/mantenimiento de este equipo, ya que al abrir o extraer las
tapas puede quedar expuesto a voltajes peligrosos u otros riesgos.

Ranuras y aberturas • 

Si el equipo posee ranuras o orificios en su caja/alojamiento, es para evitar el

sobrecalientamiento de componentes internos sensibles. Estas aberturas nunca se deben obstruir
con otros objetos.

Batería de litio • 

Existe riesgo de explosión si esta batería se coloca en la posición incorrecta. Cambiar

esta batería únicamente con el mismo tipo (o su equivalente) recomendado por el fabricante.
Desachar las baterías usadas siguiendo las instrucciones del fabricante.

Instrucciones de seguridad • Español

Precautions

im Vertrieb von

            CAMBOARD Electronics

www.camboard.de

Tel. 07131 911201
Fax 07131 911203

[email protected]

Содержание Ethernet Control Interface IPL T PCS4

Страница 1: ...IP Link Power Control Interface 68 738 07 Rev A 03 05 IPL T PCS4 and IPL T PCS4i im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard de...

Страница 2: ...iche Spannungen die nicht isoliert sind und die einen elektrischen Schock verursachen k nnen herrschen Achtung Lesen der Anleitungen Bevor Sie das Ger t zum ersten Mal verwenden sollten Sie alle Siche...

Страница 3: ...olds 3 5 Clearing thresholds 3 5 Grouping receptacles 3 6 Ungrouping receptacles 3 6 Front panel security lockout executive mode 3 6 Resetting the Unit 3 6 Chapter 4 Web Page Based Setup and Control 4...

Страница 4: ...nsafe characters 4 25 A V Device Power Control 4 26 Custom Web pages 4 26 Accessing and using Telnet port 23 4 26 Troubleshooting 4 27 Power connections 4 27 Network connections 4 27 Global Viewer Sof...

Страница 5: ...IPL T PCS4 1 Chapter One Introduction About This Manual About the IPL T PCS4 im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard de...

Страница 6: ...e associated with one or more actions such as activation of the alarm relay e mail notification etc When power exceeds or falls below a stored threshold the programmed action s are performed Power up...

Страница 7: ...mounted on a tabletop for which four feet are provided and can be attached Optional hardware for mounting the unit under a desktop or podium or on a rack shelf is not included but may be ordered separ...

Страница 8: ...ort little Rock Portland 261 7 00 310 7 30 402 9 00 410 8 30 301 4 30 222 6 00 261 7 00 310 7 30 402 9 00 410 8 30 301 4 30 222 6 00 Kansas City Lansing Oklahoma City St Lewis Tuscan Tulsa Connection...

Страница 9: ...ation and Rear Panel Installation Overview Mounting the IPL T PCS4 Interface Rear Panels and Cabling Connecting the Hardware im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 0...

Страница 10: ...PCS4 See chapter 4 Web Page Based Setup and Control or chapter 5 SIS Programming and Control 6 Plug the desired devices into the power receptacles on the PCS4 rear panel 7 Press the front panel button...

Страница 11: ...is shelf can be mounted in the front or in the rear of the rack Under desk mounting The PCS4 can also be mounted under furniture such as a table or podium surface using the optional under desk mountin...

Страница 12: ...ower cords from up to four devices to these three prong female Edison IPL T PCS4 or IEC IPL T PCS4i power output receptacles 3 Alarm relay Connect a relay controllable detection device to this single...

Страница 13: ...Wire Color 1 white orange 1 white green 2 orange 2 green 3 white green 3 white orange 4 blue 4 blue 5 white blue 5 white blue 6 green 6 orange 7 white brown 7 white brown 8 brown 8 brown RJ 45 connect...

Страница 14: ...se the supplied 14 AWG power cord for the PCS4 to function properly Remove this label before connecting the power cord to the unit 3 Plug the power cord of each device to be monitored into one of the...

Страница 15: ...Front Panel Features and Operation Front Panel Features Setting up the System Using the Front Panel Resetting the Unit im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131...

Страница 16: ...sed button to reset the unit in one of four Reset modes See Resetting the Unit later in this chapter for details on reset modes and on using this multiple function Reset button 3 Power control buttons...

Страница 17: ...of a connected device drops from Full to Standby or to None For each device you can use front panel controls to set the reference threshold Full or Standby at which a notification is triggered Until a...

Страница 18: ...eptacle number to which you connected it 1 4 2 Press the corresponding front panel button to activate the receptacle Check to ensure that the receptacle s red Power LED is lit To set the Full power th...

Страница 19: ...To indicate that the configuration has been saved both the yellow Standby LED and the green Full LED light and remain lit when those thresholds are selected None and Not Set thresholds When a Full an...

Страница 20: ...Press the receptacle button repeatedly until none of its LEDs are lit indicating no groups 3 Press the Standby or Full button to exit Configuration mode Front panel security lockout executive mode Whe...

Страница 21: ...en the unit is powered on in this mode Purpose and notes Use mode 1 to remove a version of firmware if incompatibility issues arise All user files and settings are maintained User Web pages may not wo...

Страница 22: ...Sets port mapping back to factory default Turns DHCP off Turns events off Purpose and notes Mode 4 enables you to set IP address information using ARP and the MAC address Mode 5 Activation Hold in th...

Страница 23: ...Control Configuring the Hardware Using the Embedded Web Pages Custom Web Pages A V Device Power Control Troubleshooting Global Viewer Software im Vertrieb von CAMBOARD Electronics www camboard de Tel...

Страница 24: ...e TCP IP protocol must be installed and properly configured Setting up and configuring the PC using ARP The Address Resolution Protocol ARP command provides a quick way to set up an IP address for the...

Страница 25: ...ions It is used to determine if the host has an operating connection and is able to exchange information with another host Example ping 10 13 170 15 The response should be the PCS4 s new IP address as...

Страница 26: ...an provide you with a unique IP address for the PCS4 or confirm whether you need to set up the PCS4 for DHCP Dynamic Host Configuration protocol to have an address assigned automatically when you sign...

Страница 27: ...TCP IP protocol 4 Write down your PC s current IP address and subnet mask below You will need to restore these settings to the PC later If Obtain an IP address automatically has been selected make a...

Страница 28: ...thernet port on the PC If you are using a network hub or switch between the PC and the PCS4 use a straight through Category 5 cable instead of a crossover cable 7 Set up the PCS4 s IP address See Conf...

Страница 29: ...the left of the screen A configuration System Settings Web page appears A typical settings screen is shown below Example of a default system settings page 4 IP gateway and subnet mask addresses follo...

Страница 30: ...nter the PCS4 s IP address If a password has been set the Enter Network Password dialog box opens If no password has been set the PCS4 Web page opens displaying the System Status tab Skip steps 3 and...

Страница 31: ...tem Status page displays information in the following categories System Description Includes product model a brief description part number and firmware version plus the current date and time IP Settin...

Страница 32: ...the settings submitted most recently 2 Enter your new information in the IP Settings section or select the date and time from the menus in the Date Time Settings section IP settings The following sett...

Страница 33: ...Date Select month day and or year from the pull down menus Time Select hours minutes and or AM or PM from the pull down menus Zone From the pull down menu select the time zone for the PCS4 s location...

Страница 34: ...ase sensitive 3 In the Re enter Admin Password field enter the same password again to confirm it 4 If you want to assign a User password enter it in the User Password field You cannot assign a User pa...

Страница 35: ...nter your mail server s IP address and your domain name in the appropriate fields This information is available from your network administrator 4 Click Save to save the information 5 Click the Edit bu...

Страница 36: ...ur server and double click it Firmware files must have the extension S19 The firmware file name and path are displayed in the Current Firmware Version field on the Firmware Upgrade screen 4 Click Uplo...

Страница 37: ...Grouping receptacles You may want to group two or more receptacles together to ensure that they are switched on or off at the same time You can create up to three groups To group receptacles follow t...

Страница 38: ...lay Settings section enter your selections described in the following sections 3 When you are finished making selections in one section click the Submit button at the bottom of the section to implemen...

Страница 39: ...ted for these settings to take effect Initial State Select Open or Closed from the pull down menu for the initial state of the alarm relay The default is Open Action From the pull down menu select the...

Страница 40: ...umber of the receptacle that you want to schedule and click On or Off in the Power column beside it A Set Schedule For field opens displaying the selected receptacle number the power selection On or O...

Страница 41: ...Schedule screen showing fields for daily receptacle scheduling 2 In either the Power ON or Power OFF section select the hours minutes and AM PM from the menus and select the check box es for the recep...

Страница 42: ...ering off on Tuesday Set Schedule For field to set powering off for a single receptacle 2 In the Set Schedule For field select the hour minute s and AM or PM from the pull down menus 3 Click Set to en...

Страница 43: ...te Files are listed separately under headings of their extensions Adding a directory To add a directory or folder to the IPL T PCS4 s file system follow these steps 1 Enter a name for the directory in...

Страница 44: ...cho var x where x is the SIS command to be executed When a Web page is requested the Web server removes the SSI and replaces it with the answer to the SIS command within quotes echo var SIS Command Se...

Страница 45: ...uct Name b echo var 1I b br IPLink Product Description b echo var 2I b br IPLink Product Part Number b echo var N b body html Web page HTML source code document showing SSIs The SSI commands in the pr...

Страница 46: ...imal encoding method shown below when these characters appear in your URLs The following types of characters do not require encoding in a URL alphanumerics special characters reserved characters 0 9 a...

Страница 47: ...various reasons these characters may possibly be misunderstood within a URL The following table lists unsafe characters Characters Miscellaneous characters Pound Space Percent Quotation marks Less Tha...

Страница 48: ...t port 23 Telnet short for Telecommunications Network provides a way for you to connect to a computer or server in this case the PCS4 interface on a network Once connected via Telnet you can send ASCI...

Страница 49: ...ights if the receptacle is powered on If necessary press the receptacle button to apply power 2 Ensure that all devices are plugged in properly to the rear panel of the PCS4 and switched on if applica...

Страница 50: ...al Viewer Software The Global Viewer Configurator GVC software is an alternative to using the Web pages to configure and monitor the PCS4 GVC is a free asset management software that enables flexible...

Страница 51: ...hapter Five SIS Programming and Control Host to interface Communications Using the Command Response Tables im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce inf...

Страница 52: ...ocal event such as a front panel selection or adjustment takes place the PCS4 responds by sending a message to the host No response is required from the host The following PCS4 initiated messages are...

Страница 53: ...umber response 28 cmmands that may give an E28 file not found response Using the Command Response Table The PCS4 can be controlled via either a Telnet port 23 connection or a Web browser port 80 conne...

Страница 54: ...rs must be represented as the hexadecimal equivalent xx where xx represents the two character hex byte For example a comma would be represented as 2C Characters such as and the space character must be...

Страница 55: ...rator X63 Pulse time in 20 ms per count If this parameter is missing or 0 then pulse length default 25 500 ms 35565 ms max pulse time Symbol definitions CR LF carriage return line feed hex 0D 0A Soft...

Страница 56: ...able X703 E mail to use 61 64 X704 Enable disable monitoring 0 disable monitoring 1 enable monitoring 2 enable with e mail X705 Alarm status 0 inactive 1 active 2 silenced X706 Clear value 0 condition...

Страница 57: ...1 X9 2 X9 3 X9 4 Set Executive mode on 1X 1X Exe1 Set Executive mode off 0X 0X Exe0 View Executive mode X X X5 Power receptacle monitoring and alarm functions Set alarm conditions Esc X1 X701 X702 X70...

Страница 58: ...re version that should be running however a mode 1 reset was executed and the factory default firmware version is currently loaded An exclamation point indicates corrupted firmware Request interface p...

Страница 59: ...f 24 Esc 0 DH W 0DH Idh 0 View DHCP mode Esc DH WDH X5 Set IP address 24 Esc X14 CI W X14 CI Ipi X14 View IP address Esc CI WCI X14 View hardware address MAC Esc CH WCH X18 Set subnet mask 24 Esc X19...

Страница 60: ...he same Entering duplicate port assignments results in an E13 Invalid parameter error message Set Telnet port map 24 Esc port MT W port MT Pmt port Reset Telnet port map 24 Esc 23MT W23MT Pmt 00023 Di...

Страница 61: ...te time length path directory filename x date time length path directory filename x date time length space_remaining Bytes Left Web responses HTML sample code var file new Array file 1 path directory...

Страница 62: ...data in file Example http 192 168 254 254 mypage html cmd WSF Stream files via Telnet Load file to user flash memory 24 28 Esc UF filesize filename raw unprocessed data in file up to file size Upl Ret...

Страница 63: ...PL T PCS4 A Appendix A Reference Material Specifications Part Numbers and Accessories Glossary im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard d...

Страница 64: ...T PCS4i 20 mA 4 watts at 220 VAC Maximum AC load aggregate IPL T PCS4 10 A 1000 watts at 120 VAC IPL T PCS4i 10 A 1000 watts at 220 VAC Maximum AC load individual IPL T PCS4 10 A 1000 watts at 120 VA...

Страница 65: ...each order for anIPL T PCS4 or IPL T PCS4 i interface Included parts Replacement part number IPL T PCS4 60 544 07 IPL T PCS4i 60 544 09 Rubber feet self adhesive 4 2 pin female captive screw terminal...

Страница 66: ...s so that they can be served from another Web server If you install Microsoft Internet Information Services IIS on your desktop you can serve any page on its hard disk The IPL T PCS4 functions like a...

Страница 67: ...Internet When your computer or networking device router hub interface etc is connected to a LAN or the Internet a table see ARP relates the device s IP address to its corresponding physical MAC addres...

Страница 68: ...ble delivery of data TCP IP Transmission Control Protocol Internet Protocol is the communication protocol language of the Internet Computers and devices with direct access to the Internet are provided...

Страница 69: ...lectronics Beeldschermweg 6C 1001 East Ball Road 3821 AH Amersfoort Anaheim CA 92805 USA The Netherlands Asia Japan Extron Electronics Asia Extron Electronics Japan 135 Joo Seng Road 04 01 Kyodo Build...