Connecting the Power Terminal Block
The DC power interface is a 6-pin terminal block with polarity signs on the top panel. The ISW can be
powered from two power supply (input range 12V – 58V). The DC power connector is a 6-pin terminal
block; there is alarm contact on the middle terminal block.
The switch can be powered from two power supplies (input range 12V – 58V). Insert the positive and
negative wires into V+ and V- contacts on the terminal block respectively and tighten the wire-clamp
screws to prevent the wires from being loosened.
Note
The DC power should be connected to a well-fused power supply.
Figure 8: Power Supplies
Power Connector (6P Terminal Block)
Input
DC 12-58V
PWR1 +/-
Power Input 1 +/-
PWR2 +/-
Power Input 2 +/-
ALM
Alarm relay output
Alarm Relay and Ground Connection
The alarm relay output contacts are in the middle of the DC terminal block connector as shown in
.
The alarm relay out is “Normal Open,” and it will be closed when detected any predefined failure such as
power failures or Ethernet link failures.
The relay output with current carrying capacity of 0.5A @ 24 VDC.
Installing Industrial Switches
Connecting the Power Terminal Block
ISW Series Managed Industrial Ethernet Switch Hardware Installation & User Guide
23