EPICenter Concepts and Solutions Guide
Getting Started with EPICenter
b
Click the
Look up...
button to display the
Select MIB Variable
dialog.
c
Expand the Extreme folder, select the
extremeRtStatsUtilization
variable, and click OK to
enter it into the
MIB Variable
field.
d
Type “1500” in the
Rising Threshold
field. Note that for this variable the value must be in
hundredths of a percent.
e
Type a smaller value, for example “1450” in the
Falling Threshold
field.
f
Leave the
Sample Type
as “Absolute” and the
Sample Interval
at the default value (15).
g
Select
Rising
for the
Startup Alarm
field.
2
Click the
Target
tab and do the following:
a
Select Port Group as the
Source Type
b
Select “CriticalPorts” from the
Port Groups
list
c
Click
Add
to add the Port Group to the
Selection
list
3
Click the
Apply
button to configure the rule on the device ports that are members of the
CriticalPorts port group.
A message window will appear with the device configuration results.
4
Verify that no switch configuration errors have been reported, and click
OK
to dismiss the window.
5
Click
Close
to dismiss the
New Configuration
dialog.
Configuring a CPU Utilization Rule
NOTE
CPU Utilization is only supported on switches running ExtremeWare 6.2 or later.
If you select CPU Utilization, only the Rising Threshold field allows input. The other fields and buttons
in this window are predefined.
• Rising Threshold—
A threshold value, in percent, that will trigger an event when the CPU
utilization rises past this value. This value is also used to compute a falling threshold, which is
defined as 80% of the rising threshold.
The other parameters that you can set when you configure an RMON event, are predefined in the
Extreme switch agent for a CPU Utilization event. These are:
• MIB Variable
: The MIB variable is predefined to be
extremeCpuUtilRisingThreshold.0
.
• Falling Threshold
: This is predefined as 80% of the rising threshold
• Sample Interval:
The sample interval for a CPU Utilization alarm is also predefined, and is set to 3
seconds
• Sample Type
: The sample value (a percentage) is always an absolute value
• Startup Alarm
: The Startup condition is predefined to be
Rising
NOTE
To define an alarm for a CPU Utilization threshold event, select SNMP Trap as the Event Type, then
select CPU Utilization Rising Threshold or CPU Utilization Falling Threshold as the Event Name.
Содержание EPICenter 5.0
Страница 12: ...12 EPICenter Concepts and Solutions Guide Preface...
Страница 76: ...76 EPICenter Concepts and Solutions Guide Managing your Network Assets...
Страница 92: ...92 EPICenter Concepts and Solutions Guide Managing VLANs...
Страница 116: ...116 EPICenter Concepts and Solutions Guide Managing Wireless Networks...
Страница 146: ...146 EPICenter Concepts and Solutions Guide VoIP and EPICenter Avaya Integrated Management...
Страница 163: ...Appendices...
Страница 164: ......
Страница 178: ...178 EPICenter Concepts and Solutions Guide Troubleshooting...