190
EPICenter Concepts and Solutions Guide
EPICenter Utilities
•
You can specify only one EPICenter server (database) in a command. If you want to display alarms
from multiple EPICenter databases, you must use a separate command for each server.
•
The options for specifying the relevant time period (
-h
,
-d
, and
-y
) are mutually exclusive and cannot
be combined.
•
You can specify filter options such as an alarm name or device (IP address) only once per command. If
you want to display information for a several values of a filter option, such as several alarm names,
devices, severity levels, etc., you must execute an AlarmMgr command for each value of the filter
option. For example, to display alarms for two different devices, you must execute two AlarmMgr
commands.
•
If you specify multiple filter options, they are combined in the manner of a logical AND. This means
that an alarm entry must meet all the specified criteria to be included in the command results.
•
The options for specifying the relevant time period are mutually exclusive and cannot be combined.
•
You should not combine the
-a
and
-u
options (for acknowledged and unacknowledged alarms). This
combination indicates you want to display alarms that are both acknowledged and unacknowledged.
However, there are no alarms that meet this criteria since an alarm cannot be both. To display both
alarms that are acknowledged and alarms that are unacknowledged, do not specify either option.
-c <category>
Display alarms that occur for a specific category.
Category specification is case insensitive. Must
be quoted if category name includes spaces or
other delimiters.
When these
options are
combined, an
alarm must meet
all criteria to be
included in the
results.
Each of these
options may be
specified only
once.
All
categorie
s
-s <severity>
Display alarms that occur for a specific severity.
Severity specification is case insensitive.
All
severity
levels
-dip <IP address>
Display alarms that occur for a specific device as
specified by IP address.
All
devices
-p <port>
Display alarms that occur for a specific port on
the device specified with the -dip option.
All ports
-an <alarm name>
Display alarms that occur for a specific alarm.
Alarm name specification is case insensitive.
Must be quoted if alarm name includes spaces
or other delimiters.
All
alarms
-a
Display all acknowledged alarms.
All
alarms
-u
Display all unacknowledged alarms.
-f <file specification>
Name of file to receive output. If you do not specify a path, the file is
placed in the current directory. If the file already exists, it is overwritten.
Comman
d window
(stdout).
-help
Displays syntax for this command
None
Table 9: AlarmMgr command options (continued)
Option
Value
Default
Содержание EPICenter 5.0
Страница 12: ...12 EPICenter Concepts and Solutions Guide Preface...
Страница 76: ...76 EPICenter Concepts and Solutions Guide Managing your Network Assets...
Страница 92: ...92 EPICenter Concepts and Solutions Guide Managing VLANs...
Страница 116: ...116 EPICenter Concepts and Solutions Guide Managing Wireless Networks...
Страница 146: ...146 EPICenter Concepts and Solutions Guide VoIP and EPICenter Avaya Integrated Management...
Страница 163: ...Appendices...
Страница 164: ......
Страница 178: ...178 EPICenter Concepts and Solutions Guide Troubleshooting...