background image

 

 
 
 
 
 
 
 
 

 

PELLET STOVES 

 

Instruction Manual 

 
 

INSERTO COMFORT MINI 

 

 

 
 
 
 
 

 
 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 

Содержание INSERTO COMFORT MINI

Страница 1: ...PELLET STOVES Instruction Manual INSERTO COMFORT MINI ...

Страница 2: ...Page 2 ...

Страница 3: ...any problems in using your new pellet stove AUTHORISED SPECIALIST Company___________________________________________________________________ Full name __________________________________________________________________ Address ______________________________________________ No _________________ Postal Code _________________ City _________________________________________ TEL _________________________...

Страница 4: ...ntakes 15 5 2 6 Insulation trims facings and safety precautions 15 5 2 7 National regional provincial and municipal laws 15 6 MINI COMFORT INSTALLATION 16 7 REMOTE CONTROL OPERATION 21 7 1 General description 21 7 2 Keypad 21 7 3 Display 22 8 USING THE INSERT 23 9 LIGHTING 23 10 INSERT OPERATION 24 10 1 Normal operation 24 10 2 Shutdown 24 11 USER MENUS 25 11 1 Set Temperature 25 11 2 Set Clock 25...

Страница 5: ...stove must only be used for the applications for which it was expressly designed The manufacturer declines any responsibility contractually or extra contractually for any damage caused to persons animals or property by errors in installation adjustment and maintenance or by improper use After removing the packaging check to make sure that the contents are intact and complete If this is not the cas...

Страница 6: ...et consumption per hour kg h 0 8 2 0 Absorbed electrical power W 25 100 Lighting power W 280 Power supply V Hz 230 50 Hopper capacity kg 32 Water in out pipe diameter All data are indicative and not binding The manufacturer reserves the right to make technical modifications for improving the product Minimum height The particular adjust pipe is pierced with 3 holes Ø 9 of a 90 100 distance for diff...

Страница 7: ...imum pellets also have technical advantages While the heating power of wood is 4 4 kW kg with 15 humidity after about 18 months seasoning the power of pellets is 5 3 kW kg The density of the pellet is 650kg m3 and the water content is 8 of its weight For this reason pellets do not need to be seasoned to obtain a sufficient heating yield Pellet diameters range from a minimum of 5 mm to a maximum of...

Страница 8: ...hat before lighting the stove you must be sure that the burn pot is free of dirt and debris 4 5 Temporary power failure The appliance will re light automatically after a brief power failure When the power goes off the stove may emit a minute quantity of smoke inside the house for a period of 3 to 5 minutes THIS DOES NOT POSE ANY SAFETY RISK 4 6 Electrical safety The stove is protected against viol...

Страница 9: ...produced directly or indirectly from biomass FLUE or CHIMNEY Vertical duct for collecting and expelling combustion products from a single appliance at a suitable height from the floor EXHAUST CHANNEL OR PIPE Duct or connecting element between the heat generating device and the chimney for extracting the combustion products INSULATION The series of measures taken and materials used to prevent heat ...

Страница 10: ...he appliance keeping in mind the following Installation prohibitions Legal clearances Limitations set forth by local administrative regulations or specific regulations of the authorities Common limitations deriving from building regulations and easement or contract regulations Admissible installations In the room in which the heat generator is to be installed any existing or installed appliances m...

Страница 11: ...l exhaust outlets have to be reached that are not coaxial in relation to the exhaust outlet from the appliance the direction changes must be made using open elbows no greater than 45 see figures below For heat generating devices equipped with an electric exhaust fan i e all products made by Extraflame it is necessary to observe the following instructions Horizontal sections must have a minimum slo...

Страница 12: ...cal stress as well as heat and the action of combustion products and any condensates have a predominantly vertical layout with deviations from the axis no greater than 45 be situated at a proper distance from combustible or flammable materials by means of an air gap or suitable insulation material REFERENCES Flammable objects Non flammable objects A 200 100 B 1500 750 C 200 100 preferably have a r...

Страница 13: ...on of solid materials and any condensates located below the mouth of the exhaust channel so that it is easy to open and inspect from the airtight hatch Maximum 3 m 3 5 Inspection Windproof chimney cap Flue Inspection External insulated duct Inspection Maximum 3 m 45 Inspection ...

Страница 14: ...of the chimney be constructed in such a way as to prevent the penetration of rain snow and foreign bodies into the chimney as well as to assure the discharge of the combustion products also in the presence of winds coming from any direction and at any angle be positioned in such a way as to assure proper dispersion and dilution of the combustion products and in any case outside the reflux area in ...

Страница 15: ...hrough permanent openings communicating with the outside The adjacent room must not be subject to depression with respect to the outside as a result of the opposing draught caused by the presence of another utility device or suction device in this room In the adjacent room the permanent openings must meet the requirements described above The adjacent room cannot be used as a garage storage area fo...

Страница 16: ...e Drill the holes for 8 mm steel screw anchors Drill a 60 mm hole in correspondence with the air intake N B The air intake must be made outside the fireplace because it must not draw in overheated air Provide a power outlet on the rear of the insert so that the plug can be reached easily once the installation is complete Fix the base using the attachment screws Make the connection to the exhaust o...

Страница 17: ... air intake as described in the previous section Then tilt the insert so that the wheels fit into the guide rails slide it until the exhaust auger coupling is completely inserted in the exhaust conveyor box Then use the socket wrench provided to turn the screw anticlockwise To check that the insert is correctly coupled with the base connect the plug to the power outlet the display should light up ...

Страница 18: ...wise 2 Using the pokers provided pull the insert towards you until it blocks automatically Fitting the frames Front frame Side frames Attach the front frame to the two side frames Fix the frames to the Comfort insert using self tapping screws N B Any wooden beams situated above the insert must be protected using fireproofing material Frame assembly is important as it allows correct air circulation...

Страница 19: ...ides of the fireplace Minimum measurement required 200 cm2 per side Air intake made on the front of the fireplace Minimum measurement required 400 cm2 per side For fresh air intake it is very important to make one or more holes on the lower or side part of the facing N B This ventilation system is completely independent from the combustion air intake These air circulation points must have a minimu...

Страница 20: ...es NB The exhaust outlet pipe must always be at a minimum distance of 5 cm from inflammable parts Warm convection air It is necessary provide an outlet for the heat accumulated in the facing to prevent excessive overheating of the insert Forced ventilation The blower conveys the heat produced in the insert into the room Air intake from the room To enable air circulation it is necessary to have an ...

Страница 21: ...ress buttons 4 and 5 together for three seconds until SCEGLI UNITA appears on the display 5 Use button 4 or 5 to select the desired coding from 0 to 3 6 Power up the stove 7 The stove will emit two acoustic signals between the first and the second press button 1 for 1 second At this point the display will show EXTRAFLAME General characteristics The visual interface is given on an LCD display with ...

Страница 22: ...nu 2 2 buttons These buttons are used for accessing and setting the user parameters 7 3 Display The display messgage changes in relation to the status of the stove or the menu being display In resting status the display shows the following TIME The current time is shown The time is set within the weekly programmer see SET CLOCK menu ROOM TEMPERATURE Shows the current room temperature HEATING POWER...

Страница 23: ...er outlet is connected f the switch on the back of the stove is in position 1 2 Press button 1 for three seconds display D1 will show the message START During this stage the stove carries out an automatic check on the efficiency of each single electrical component When this cycle is completed display D1 shows the message ACCENSIONE 15 the number of minutes for which the stove attempts the lighting...

Страница 24: ... of fuel ATTENTION 1 The cover of the pellet container must always be kept closed except when loading fuel 2 The sacks of pellets must be kept at least 1 5 metres away from the stove 3 The hopper should always be kept at least half full 4 Before refilling make sure that the appliance is switched off 10 2 Shutdown Press button 1 for three seconds When the three seconds have elapsed the stove automa...

Страница 25: ...ns enable the increase decrease of the room thermostat value from a minimum of 07 C the display shows MIN to a maximum of 40 C the display shows MAS This value is shown on the first line of the display the third and fourth lines show SET TEMP AMBIENTE When you have set the desired value confirm with button 1 11 2 Set Clock Menu This procedure is used for activating disactivating the weekly program...

Страница 26: ...bles for switch on off must be consecutive within the same day on a 24 hour basis from 0 to 24 and not straddling more than one day e g Switch on 07 00 switch off 18 00 OK Switch on 22 00 switch off 05 00 WRONG The programming procedure can be carried out with the stove on or off and involves the following steps 1 Press the menu 1 button the display will show SET TEMP AMBIENTE 2 Press the menu 1 b...

Страница 27: ... 7 DAY ON 2 Used for setting which days of the week to enable disenable the time period set The procedure is as follows c button 5 to scroll the days a button 4 to enable disenable ON OFF the first time period for that day To confirm and continue with programming press the menu 2 button To return to the previous parameter press the menu 1 button Parameter 8 START PROGRAM 3 Use buttons 4 and 5 to s...

Страница 28: ...the menu 2 button To return to the previous parameter press the menu 1 button Parameter b DAY START Use buttons 4 and 5 to set the day start night end To confirm and continue with programming press the menu 2 button To return to the previous parameter press the menu 1 button Parameter c DAY END Use buttons 4 and 5 to set the day end night start To confirm and continue with programming press the me...

Страница 29: ...king the air intake holes due to the excessive pellet load that is only partially burned N B If this problem occurs just a few months after installation check to make sure that the user is correctly carrying out the regular cleaning schedule described in the instruction manual The adjustment is made on a percentage basis and therefore any change of this parameter leads to a proportional variation ...

Страница 30: ... If the problem is reduced but not resolved decrease by a further 5 percent Repeat this process until the problem is resolved If the problem cannot be resolved contact the service centre 11 6 Language Menu You can choose among the following languages available ITALIAN ENGLISH FRENCH GERMAN To access this menu proceeds as follows 1 Press the menu 1 button the display will show SET TEMP AMBIENTE 2 P...

Страница 31: ...switched on off by means of a supplementary thermostat see Mechanical thermostat with energy saving To exclude this function simply raise the room temperature by pressing button 3 DOFF The stove is off due to the Day Night Temperature Function and on standby to be re started To stop the stove from starting again due to the Day Night Temperature Function press button 1 and hold for three seconds wh...

Страница 32: ... authorised technician MANCATA FIAMMA The pellet hopper is empty The spark plug is faulty or out of position Inadequate pellet feed setting Check the level in the pellet hopper Check the procedures described in Lighting Adjust the flow of pellets see Pellet Feed Adjustment Other restore operations must be carried out by an authorised technician MANCATA FIAMMA BLAC OUT No electricity during the lig...

Страница 33: ...nician Exhaust motor operation This LED is on off when the exhaust motor is running not running Pellet feed motor operation This LED is on off when the pellet feed motor is running not running During normal operation this LED lights up intermittently Blower operation This LED is on off when the blower is running not running Communication established between remote control and stove Each time you p...

Страница 34: ...d contact the stove switches on and operates at the power set and the display shows T ON Thermostat with open contact the stove goes to the minimum power even if the display shows the previously set value the display will then show MIN 12 4 Mechanical thermostat with energy saving Standby function Stby The Standby function is used to further reduce pellet consumption by switching off the stove whe...

Страница 35: ...Page 35 13 WIRING DIAGRAM ...

Страница 36: ... indicated by the arrows in Fig 3 should be emptied as needed using a vacuum cleaner Figure 3 4 CLEANING THE HEAT EXCHANGER monthly The heat exchanger chamber should be cleaned once a month as the soot deposited on the back of the cast iron firewall obstructs the normal flow of the fumes To access the heat exchangers you have to remove the central piece of the firewall as follows Remove the burn p...

Страница 37: ...e checked periodically and replaced immediately if worn or damaged These operations must be carried out by an authorized technician N B To ensure correct operation the stove should have general maintenance performed at least once a year by an authorized technician If the power cable is damaged it must only be replaced by the service centre or by a qualified technician in order to avoid any risks 1...

Страница 38: ...ini Comfort insert has a partition fixed to the burn pot by a screw which makes it possible to optimise the stove combustion processes WARNING Removing the burn pot partition can jeopardise stove safety and immediately voids the warranty ...

Страница 39: ...e even if such works have to be carried out following the replacement of malfunctioning parts EXTRAFLAME S p A guarantees that its products are manufactured with the best quality materials and with fabrication techniques that guarantee perfect efficiency If during normal use of the product any parts should show to be defective or malfunctioning these parts will be replaced free of charge by the ve...

Страница 40: ... dimensional differences in the majolica parts shall not constitute reasons for claims as they are natural characteristics of these materials Building works For thermo products the parts of the plumbing system not supplied by EXTRAFLAME S p A The warranty excludes any calibrations or adjustments of the product based on the type of fuel or the type of installation This warranty is valid only for th...

Страница 41: ...eated by our company in full respect for Italian Law 196 2003 for the entire duration of the contractual relationships established and also thereafter for the fulfilment of all legal obligations as well as to carry out effective management of the commercial relationships The data may be communicated to other external subjects only for the purpose of overseeing credit matters and for the protection...

Страница 42: ...Page 42 Notes ...

Страница 43: ...Page 43 Notes ...

Страница 44: ...LAME S p A Via Dell Artigianato 10 36030 MONTECCHIO PRECALCINO Vicenza ITALY Tel 0445 865911 Fax 0445 865912 http www extraflame com E mail info extraflame com 004275115 REV 003 21 03 2006 Manuale d uso e manutenzione I C Mini uk ...

Отзывы: