Page 34
ALARMS
Message
Display D1
Cause
Solution
Indicates the presence of an alarm
This indicator lights up when one of the alarms described
below is in progress and is accompanied by the
corresponding indication on display D1. To reset the alarm,
press button 1 and hold for three seconds when the stove
is completely cold.
If the light is flashing, it indicates that the depression
sensor is deactivated.
All resetting operations must be carried out by an
authorised technician
Fum Fail
The flue gas motor is blocked.
The speed control probe is faulty.
No power supply to the flue gas motor.
All resetting operations must be carried out by an
authorised technician
Fumi tc
The flue gas probe is broken.
The flue gas probe is disconnected from
the board.
All resetting operations must be carried out by an
authorised technician
High Temp
The cross-flow fan is faulty.
Excessive pellet feed.
No power supply to the cross-flow fan.
Adjust the flow of pellets (see
“Pellet Load Adjustment”
).
Other resetting operations must be carried out by an
authorised technician.
Depr Fail
The flue gas exhaust pipe is obstructed.
The combustion chamber is dirty.
The pressure sensor is faulty.
The ash drawer is not closed properly.
The door is not closed properly.
Check to make sure that the exhaust outlet and the
combustion chamber are clean.
Check to see if the drawer is sealed properly.
Check to see if the door is sealed properly.
Other resetting operations must be carried out by an
authorised technician.
No Acc
The pellet tank is empty.
The spark plug is faulty or out of position.
Inadequate pellet load setting.
Check the level in the pellet tank.
Check the procedures described in “
Ignition”
.
Adjust the flow of pellets (see
“Pellet Load Adjustment”
)
Other resetting operations must be carried out by an
authorised technician.
No Acc
Blac Out
No electricity during the lighting phase.
Press button 1 to switch off the stove and repeat the
procedure described in “
Ignition
”.
No pell
The pellet tank is empty.
Pellet feeding is insufficient.
The feed motor still has to settle in.
The geared motor is not loading pellets.
Check the level in the pellet tank.
Adjust the flow of pellets (see
“Pellet Load Adjustment”
).
Other resetting operations must be carried out by an
authorised technician.
Hight H2O
The circulation pump is blocked.
Insufficient system pressure.
Presence of air in the system.
Check the pressure of the water system.
Bleed the air from the system.
Other resetting operations must be carried out by an
authorised technician.
Atte + allarme
Attempt to release alarm with stove still
cooling
Every time the stove visualises one of the above-listed
alarms it will automatically switch off.
The stove will block any attempt to release the alarm
during this phase visualising the alarm itself and ATTE
alternately .
Release of the alarm using button 1 is only possible when
the appliance is switched off.
Nr. telefono
- - - - - - - - - -
Display
of
the
service
centre
telephone number.
When an alarm occurs, the type of alarm detected
and the telephone number of the service centre flash
on the display in alternation.
If the number has not been entered, the display
shows a series of dashes.