Page 23
12. USER PARAMETERS
USER PARAMETERS
WATER TEMPERATURE ADJUSTMENT
Display D1 Display D2
Function
70°C
Water temperature adjustment
WEEKLY PROGRAMMER
Display D1 Display D2
Function
off
0
Act./ Deact. Weekly programmer
00:00
1
1st ignition time
00:00
2
1st switch-off time
off 1
3
Consents for 1
st
ignition /switch-off for the various days
00
4
Installer parameter
00:00
5
2nd ignition time
00:00
6
2nd switch-off time
off 1
7
Consents for 2
nd
ignition/switch off for various days
00:00
8
3
rd
ignition time
00:00
9
3
rd
switch-off time
off 1
A
Consents for 3
rd
ignition /switch-off for the various days
DAY-NIGHT TEMPERATURE FUNCTION
Display D1 Display D2
Function
06:00
B
Start day period/ end night period
22:00
C
Start night period/ end day period
25
D
Day period max. temperature
20
E
Night period max. temperature
PELLET LOAD ADJUSTMENT
Display D1 Display D2
Function
00
F
% pellet load adjustment
12.1 Water temperature adjustment
This function allows the user to set the desired water temperature. Press and hold button
3
to
access this parameter
,
press button
5
and release the 2 keys at the same time.
In display D1 flashing
“H2O”
(water) and
“70°C”
will appear. This corresponds to the value that
can be modified while nothing appears on display D2.
Use keys
2
and
3
to adjust the desired temperature with a maximum range from 40 to 90°C. To
confirm use key
1
.
12.2 Weekly programmer
The weekly programmer functions allow the user to programme 3 phases within a day to use on
all days of the week. The ignition and switch off times must be included within the span of one
day, from 0 to 24, and not overlapping several days:
E.g.
ignition at 07:00 / switch-off at 18:00
OK
ignition at 22:00 / switch-off at 05:00
ERROR
Содержание EcoLogica Idro
Страница 6: ...Page 6 ...
Страница 31: ...Page 31 14 WIRING DIAGRAM Wiring diagram ...