Page 11
FLUE GAS VENTING SYSTEM
A system for flue gas exhaust venting that is independent from the appliance, composed of a pipe
or channel, chimney or single flue, and chimney cap.
FORCED DRAUGHT
Air circulation by means of a fan driven by an electric motor.
NATURAL DRAUGHT
Draught resulting in a chimney/flue due to the difference in the volume mass existing between the
(hot) fumes and the surrounding atmospheric air, without any mechanical suction aid installed
inside or on top of it.
RADIANCE AREA
Area immediately adjacent to the hearth in which the heat produced by combustion is diffused;
this area must not contain any objects made of combustible material.
REFLUX AREA
Area in which the combustion products come out from the appliance towards the room in which it
is installed.
5.2 Installation
Before carrying out installation, it is necessary to check the positioning of the chimneys, flues or
exhaust terminal ducts of the appliance, bearing in mind the following:
•
Installation prohibitions
•
Legal clearances
•
Limitations set out by local administrative regulations or specific regulations of the
authorities.
•
Common limitations deriving from building regulations, and easement or contract
regulations.
Admissible installations
In the room in which the heat generator is to be installed, any existing or installed appliances must
be airtight to the room and must not cause depression in the room with respect to the external
environment.
Appliances used for cooking foods and the related hoods without extractor can only be installed in
rooms used as kitchens.
Prohibited installations
The room in which the heat generator is to be installed must not contain any of the following
devices, either pre-existing or installed:
- Hoods with or without extractor;
- Ventilation ducts of the collective type.
Should these devices be located in adjacent rooms communicating with the installation room, it is
forbidden to use the heat generator simultaneously where there is the risk that one of the two
rooms may be subject to depression with respect to the other.
Содержание EcoLogica Idro
Страница 6: ...Page 6 ...