set boiler
The menu allows the user to set the boiler in the BiOmass mode, the boiler functions exclusively without controlling other auxiliary boilers
present in the system; BiOmass/aUx, where the boiler can also manage an auxiliary boiler or aUx where the pellet boiler is excluded from
functioning to leave just the auxiliary in operation.
CONTrOls prOCeDUre
press key 6 and
set power
will appear.
press key 2 several times until
settinGs
is displayed.
press key 6.
press key 2 until
set boiler
is shown and use key 6 to confirm.
press keys 4-5 to configure the setting.
press key 1 several times to confirm and exit the menu.
enable boiler timer
boiler CHrono
Cannot be aCtivateD
N.B.: Diadema aCS features an instantaneous heat exchanger for the production of domestic hot water and it is not possible to set the
Boiler timer
season
in sUmmer mode, the room thermostats relative to the heating system are satisfied. in addition to the areas, the request by a puffer is
inhibited: the boiler will only operate to satisfy the DHW request. in WiNTer mode, all requests are instead considered.
CONTrOls prOCeDUre
press key 6 and
set power
will appear.
press key 2 several times until
settinGs
is displayed.
press key 6.
press key 2 until
season
is shown and use key 6 to confirm.
set
summer or winter
with keys 4-5.
press key 1 several times to confirm and exit the menu.