![Extraflame DIADEMA ACS IDRO Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/extraflame/diadema-acs-idro/diadema-acs-idro_user-manual_2454245013.webp)
OFF
13
ENGLISH
Control panel
BUTTON
ON/OFF
Display OF variOUs
TexT messages
TO aCCess
THe meNU
seTTiNg
TemperaTUre
OperaTiON pOWer
aDJUsTmeNT
Display iCons key
indicates the receipt of the radio signal
On = during radio communication
Off = no radio communication
Flashing = serial port excluded
indicates the stove modulation
On = the stove is working at the set power
Flashing = the power at which the stove is working is different to
the power set, the stove is modulating (for various reasons)
indicates the presence of an alarm.
On: indicates the presence of an alarm
Off: indicates the absence of alarms
Flashing: indicates the deactivation of the depression sensor.
it indicates weekly programming functioning
indicator on = weekly programming active
indicator off = weekly programming disabled
indicates the water temperature status
Off = the T° read by the probe is above the set temperature
On = the T° read by the probe is below the set temperature
indicates the contact of the external additional thermostat
Contact closed: the contact of the external additional thermostat is
closed and the sTBy function is disabled.
Contact open: the contact of the external additional thermostat is
open and the sTBy function is disabled.
Flashing with contact closed: the contact of the external additional
thermostat is closed and the sTBy function is activated
Flashing with contact open: the contact of the external additional
thermostat is open and the sTBy function is activated
it indicates fumes motor operation.
Off = fumes motor disabled
On = fumes motor active
Flashing = breakdown (contact technical after-sales service)
it indicates the summer / winter function
Off: activates the winter function
On: activates the summer function
Not used
indicates the DHW request
Off: DHW satisfied, pump off
Flashing : the DHW request exists but the work conditions are not
satisfied, pump off
On : the DHW is in request mode and the work conditions are
satisfied, pump on
it indicates pellet feed motor operation
Off = pellet feed motor disabled
On = pellet feed motor active
indicates the heating request
Off : heating satisfied, pump off
Flashing : the heating request exists but the work conditions are
not satisfied, pump off
On : the heating is in request mode and the work conditions are
satisfied, pump on
it indicates pump operation
Off = pump deactivated
On = pump active
Flashing = the safety device is active (H2O temperature > 85°C)
indicates the puffer request, if active.
Off : puffer satisfied, pump off
Flashing : the puffer request exists but the work conditions are not
satisfied, pump off
On : the puffer is in request mode and the work conditions are
satisfied, pump on