Instruction Manual
ExTox IMC-8/-4
Page 22 of 24
BA_IMC-8_-4_e_2011-09-20.doc
7
Application
Here the application remarks in the Instruction Manual of the Control Units Series ET-8D and
ET-4D2 are valid.
8
Installation
The following figure shows the modular construction of the IMC.
Measured Gas Pump
Flame Arrestor,
automatic
condensate trap
Gas connection,
condensate outlet
Space for
Gas Transmitters
Flow Rate
Monitoring
Connection PCB for
transmitter and digital
inputs and relays
outputs
Cable glands
8.1
Mechanical Installation
The wall mounted housing should be installed at an easily accessible place to enable the read-
ing out of messages at every time and to ensure an easy maintenance.
Please pay attention to the indicated operation temperature for the IMC and build in transmit-
ters (
)
DB). The IMC should be installed protected against weather conditions and bigger cli-
matic fluctuations.
The dimensions for assembly and further installation dimensions can be taken from the Techni-
cal Data Sheet (
)
DB). The wall mounted housing can be opened by means of a usual two cam
lock key.
The IMC itself may not be installed in hazardous areas. The air change via ventilation of the
housing is that designed that in case of a leakage in the internal hosing the measured gas is
always that much diluted that a hazardous gas mixture cannot occur inside the housing. Due to
the rotary speed monitoring of the two fans the function of the so called "inner explosion pro-
tection" is ensured.