![ExTox 420106 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/extox/420106/420106_instruction-manual_2454121027.webp)
Integral Measuring Concept IMC-8D(A)2
Article-No.: 420106 (420107)
ExTox Gasmess-Systeme GmbH
●
Max-Planck-Straße 15 a
●
59423 Unna (Germany)
●
Tel. +49 2303 33 247-0
●
Fax +49 2303 33 247-10
Internet: www.extox.de
●
mail to: [email protected]
420106_420107_IMC-8D_A2_e_2011-09-20.doc,21/02/2012Seite 1 von 2
Description
Integral Measuring Concept:
Sampling and conditioning of measured gas, transmitter and evaluation
combined in one compact wall mounted housing.
At the same time possibility of continuous monitoring of ambient air.
Eight 4-20 mA-Outputs (only 420107: IMC-8DA2)
Features
Transmitter
▪
Number: 1 to 8
▪
Allocation of transmitter inputs to analysis including sampling and condi-
tioning of measured gas as well as monitoring of ambient air freely se-
lectable
▪
Selection out of ExTox-Series Sens(-I) and ExSens(-I)
Signal Processing
▪
Control Unit ET-8D or ET-8DA for 8 transmitter inputs, incl. 20 freely
configurable relay outputs and serial interface; additionally control of
sampling and conditioning of measured gas as well as evaluation of
status messages.
▪
Software Extension IMC
▪
Continuous monitoring of ambient air
Sampling of Measured Gas
▪
Gas suction pump and electronic flow rate monitoring
▪
Maximum length of sample line
≥
50 m
▪
Manual condensate trap
▪
Magnetic valve to change from measured gas to test gas
▪
Hosing: PE/PP
▪
Dust filter
Connections
At the bottom of the housing for 4/6-Hose (inner / outer Ø: 4/6 mm)
▪
3 glands for measured gas inlet, test gas and gas outlet
▪
1 gland for condensate outlet
Operation Temperature
+5 °C to +40 °C
Pressure at sampling point
-100 hPa to +100 hPa (relative to ambient)
Mechanical Features
Dimensions
Standard version: 760 mm x 600 mm x 350 mm (Height x Width x Depth)
Housing
Wall mounted housing with door, mounting plate, foamed-in door sealing,
2 cam locks
Material
Steel, powder-coated in textured RAL 7035
Climatisation
2 fans, rotary speed monitored (at the same time leakage protection)
Storage Temperature
-25 °C to +60 °C
Electrical Features
Power Supply
▪
230 V AC
▪
Power Supply 230 V AC/24 V DC, 120 W integrated
Cable Gland
At the bottom of the housing
▪
1 x M20 x 1.5 (diameter of cable 7-13 mm)
▪
10 x M16 x 1.5 (diameter of cable 5-10 mm)
Terminal Assignment
▪
Power supply
▪
Central connection PCB for transmitter and digital inputs and relay out-
puts
Measuring Gas
Pump
Sensors
Gas
Conditioning
Measuring gas
Ambient Air
Transmitter
ET-8D